{"title":"Quincy Air Compressors","description":"\u003cp\u003eShop Quincy air compressors for auto shops, garages, and service centers. Explore rotary screw and reciprocating compressors designed to power pneumatic tools, shop equipment, and professional automotive service work.\u003c\/p\u003e","products":[{"product_id":"quincy-air-compressor-10-hp-120-gallon-rotary-screw-208-230-460v-3-phase","title":"Quincy Air Compressor 10 HP 120 Gallon Rotary Screw 208-230\/460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10 HP oil-injected rotary screw compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e38.8 CFM at 125 PSI on a continuous 100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving shops a steady supply of compressed air without the rest periods required by duty-limited piston compressors. It pairs the rotary screw airend with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, TEFC motor, and long-life V-belt drive for demanding applications. The unit runs on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V, 230V, or 460V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and measures 76\" L × 25\" W × 58\" H. Note: site wiring must be completed by a licensed electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe rotary screw design uses continuously rotating rotors rather than reciprocating pistons, reducing vibration while allowing the compressor to run continuously. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAuto-Dual control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e adds flexibility by allowing a timed shutdown when there is no air demand, helping avoid unnecessary energy use during idle periods. The system also uses premium synthetic lubricant rated for up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping extend service intervals while maintaining low oil carryover and reducing the load on downstream air filtration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis compressor is well suited for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emulti-bay automotive and tire shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, light manufacturing facilities, production areas, and other operations where compressed air demand is frequent or continuous. It is also a practical upgrade for shops moving away from duty-limited piston compressors and for facilities with changing work schedules that can benefit from adjustable automatic shutdown. With its compact footprint and continuous-duty design, it provides a dependable compressed-air source for applications where pressure availability throughout the workday matters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto-Dual Control: More Than an On\/Off Switch\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe unit features \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAuto-Dual control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing you to set a timed shutdown instead of leaving the compressor running indefinitely between periods of demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA rotary screw compressor still consumes significant power while running unloaded — the airend and cooling fan continue operating even when no compressed air is being delivered. In a shop with irregular demand, Auto-Dual lets you set the compressor to shut down automatically after a defined period without air usage, helping reduce unnecessary energy consumption.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor shops with steady demand, the shutdown interval can simply be set longer so the compressor remains available and ready to respond. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eOne control system accommodates two very different operating profiles, giving you control over how the compressor runs.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy a Screw Compressor Is Designed for Continuous Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eUnlike a reciprocating compressor, where the piston repeatedly changes direction on every stroke, a rotary screw compressor uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo rotors that turn continuously in the same direction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Oil is injected into the compression chamber to seal, cool, and lubricate the rotors during operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause there is no constant start-stop reversal of a piston, the compressor produces less vibration and is designed for sustained operation. This contributes to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty-cycle rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making continuous operation a fundamental part of the machine's design rather than simply a performance figure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLubrication and Downstream Air Cleanliness\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epremium synthetic lubricant rated for up to 8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. This helps extend service intervals while maintaining effective lubrication and cooling of the airend.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProper oil separation also helps minimize oil carryover into the compressed-air stream. Lower carryover can reduce the burden on downstream filtration and help deliver cleaner air to your tools and equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 76\" L × 25\" W. The relatively narrow footprint provides substantial airflow output without consuming excessive floor space. However, adequate clearance must be maintained around the cooling-air intake, exhaust, and service areas.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 58\" overall.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 775 lbs.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Three-phase, 208V, 230V, or 460V. Quincy does not publish a specific amp draw or breaker size for this configuration and specifies that the unit must be wired on site by a licensed electrician. Electrical requirements should therefore be confirmed before delivery.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir Connection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\/2\" tank outlet. Properly sizing the shop's air piping is important, particularly on longer runs, where undersized piping can create unnecessary pressure loss.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThe customer is responsible for the slab, electrical feed, disconnect, on-site wiring, compressed-air piping, and condensate management.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMulti-bay automotive and tire shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where compressed-air demand is frequent and recovery time affects productivity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLight manufacturing and production environments\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using pneumatic tools, equipment, or actuators.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities replacing a duty-limited reciprocating compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need more consistent air availability.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops with variable operating schedules\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where Auto-Dual's timed shutdown can be adjusted to match actual demand.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003erotary screw airend, TEFC motor, V-belt drive, 120-gallon receiver tank, enclosure, Auto-Dual control, magnetic starter, and synthetic lubricant charge\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe installation package does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e include site wiring, electrical disconnects, shop air piping, point-of-use filtration, or regulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCompressor type\u003c\/th\u003e\n\u003ctd\u003eOil-injected rotary screw, V-belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir delivery\u003c\/th\u003e\n\u003ctd\u003e38.8 CFM at 125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003eContinuous, 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e3-phase, 208, 230 or 460V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eControl\u003c\/th\u003e\n\u003ctd\u003eAuto-Dual, with timed shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e76\" long × 25\" wide × 58\" tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e775 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003ePremium synthetic, rated to 8,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor type\u003c\/th\u003e\n\u003ctd\u003eTEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur records list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eone certification for this unit: the ASME pressure-vessel code for the receiver tank\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. This is a legitimate third-party construction and testing standard for the pressure vessel itself. It should not be interpreted as certification of the compressor's electrical assembly, controls, or enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe have \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eno record of an additional third-party safety listing for this machine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and we will not imply otherwise.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis distinction can matter when installing permanently mounted shop equipment. Certain insurers, fleet policies, or local authorities may require a specific third-party safety listing before approving an installation. If that applies to your facility, determine exactly which certification or listing is required and verify that it matches the unit's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edata plate and factory documentation before purchasing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBefore You Order — Please Confirm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWhether an air dryer is fitted.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e This is the most important point to confirm on this listing. The product feature list references an integrated refrigerated air dryer, while our specification record for the same unit states \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e“No”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for the air dryer. Those two records cannot both be correct. A dryer is not a minor detail — it affects the purchase price, footprint, condensate management, and whether the compressed air is suitable for applications such as painting. For that reason, we are \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot claiming that a dryer is included, nor are we claiming that it is absent\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. If dry air is a requirement for your application, contact us and we will verify the exact factory configuration against the order documentation before the unit ships.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSound level.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The enclosed design is intended to help reduce operating noise, and current product information describes the machine as quiet. However, the decibel figure in our available data is not documented with a verifiable measurement standard or test condition, so we are not publishing a specific noise rating. If your installation has a required sound limit, contact us before ordering so we can determine what documentation is available.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFreight to the lower 48 states is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003equoted live at checkout based on your delivery address\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor ships as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e775-lb palletized unit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so make sure the unloading method is arranged before delivery. Depending on your location and facility, you may need a forklift, loading dock, or carrier-terminal pickup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential deliveries may incur an additional residential delivery fee, which will be reflected in the freight quote at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment immediately upon arrival.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the enclosure panels, receiver tank, feet, controls, and other accessible components for visible damage. If you find damage, document it and have it noted on the bill of lading \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore signing for the shipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A clean delivery receipt can make a later freight-damage claim substantially more difficult.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThere are three warranty levels associated with this compressor, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estandard factory warranty is the one included automatically\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStandard factory warranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1 year\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eExtended factory warranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3 years, available as an option\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-year warranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Available when the compressor receives a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy-authorized start-up\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 5-year warranty is conditional on the authorized start-up; it is not simply an automatic upgrade that can be added after installation. If the extended coverage is important to you, arrange the authorized start-up as part of the installation process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025.pdf?v=1788313880\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45946499137589,"sku":"4152021972","price":10604.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152021972__73412.1679921471.1280.1280.jpg?v=1788031024"},{"product_id":"quincy-air-compressor-10-hp-120-gallon-rotary-screw-with-dryer","title":"Quincy Air Compressor 10 HP 120 Gallon Rotary Screw with Dryer","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QGS 10 HP rotary screw compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e38.8 CFM at 125 PSI on a 100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving shops continuous compressed air without the recovery periods common with reciprocating compressors. This 120-gallon horizontal package is also the only QGS configuration on this receiver whose specifications list an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eintegrated aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, paired with the refrigerated dryer for more effective moisture removal. The long, low-profile design measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e76\" L × 25\" W × 58\" H\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs 850 lbs. Note: requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208-230\/460V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a certified electrician should size the service and disconnect from the nameplate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe combination of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eaftercooling and refrigerated drying\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is particularly useful in a busy shop. Hot, saturated air leaving the screw element is cooled first, allowing much of the condensed moisture to be removed before the air reaches the dryer. That gives the dryer cooler inlet air to process and helps deliver drier compressed air to downstream equipment. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAuto-Dual control system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e also allows scheduled shutdowns, so the compressor can stop during programmed idle periods instead of maintaining pressure when the shop is empty. A TEFC motor, long-life V-belt drive, synthetic lubricant rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, low-oil shutdown, and oil sight glass round out a design built for regular service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis compressor is a practical step up for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo- and three-bay independent repair shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, tire and fleet operations, and small fabrication facilities that have outgrown piston compressors. Its continuous 38.8 CFM output can support multiple air tools, sanders, smaller blast cabinets, tire equipment, and lifts, but it is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot intended for high-demand applications such as production spray booths or large media blasters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It also suits serious home or collector garages that already have the required three-phase electrical service and floor space for a horizontal receiver.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it fit, and can you power it?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt 76 inches long, 25 inches wide and 58 inches tall, this 850-lb package is the lightest configuration available on this receiver — an important detail if the floor has any load limitations. Its long, low profile means the main installation constraint is usually the length of wall space available, along with adequate service clearance at the panel end, rather than ceiling height. The receiver outlet is 1\/2 inch, so your header sizing should start there.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrically, this is a 208–230\/460V, 3-phase unit with a magnetic starter already fitted. A licensed electrician is required for the installation, and Quincy is explicit that the amp draw and recommended breaker size are not published for this model; both specifications are listed as “Consult Certified Electrician.” We will not fill those gaps with estimates. Have the electrical service, feeder and disconnect sized from the machine’s nameplate before it arrives. Supply, installation location and any required permits are the customer’s responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTwo- and three-bay independent workshops that have outgrown a piston compressor. Mobile tire and fleet operations with a permanent base. Small fabrication shops that need dry air for plasma work. Serious home and collector garages with three-phase service and enough room for a long horizontal package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIt is the sensible first step into rotary screw compression — capable enough for demanding shop work without jumping straight to the largest machine in the lineup.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP, electric, TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFree air delivery\u003c\/th\u003e\n\u003ctd\u003e38.8 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e208-230\/460V, 3-phase, magnetic starter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmp draw \/ breaker\u003c\/th\u003e\n\u003ctd\u003eManufacturer states \"Consult Certified Electrician\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, oil-lubricated, long-life V-belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eFitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallon horizontal, 1\/2-inch outlet, no electronic drain valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir treatment\u003c\/th\u003e\n\u003ctd\u003eIntegrated refrigerated dryer plus air filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e76 in x 25 in x 58 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAccording to the manufacturer's feature list and specification table, the package includes the QGS rotary screw compressor with a long-life V-belt drive, integrated refrigerated air dryer, aftercooler, 120-gallon horizontal receiver, TEFC electric motor, standard quiet enclosure, Auto-Dual control, air filter, pressure gauge, oil sight glass, low-oil shutdown for the engine and pump, and factory-filled premium synthetic lubricant.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn electronic drain valve is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e included. Plan on a manual condensate-draining routine or budget for an automatic drain separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping and delivery\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit ships by freight within the lower 48 states, with the current rate calculated at checkout based on your delivery address. We deliberately do not publish a fixed shipping price because freight costs change, and an outdated figure creates more confusion than value.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eEven though this is the lightest unit in this group, it is still far too large for standard curbside handoff. Before shipment, arrange the equipment needed to unload it — typically a loading dock, forklift, or terminal pickup. Residential delivery will incur an additional residential fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the crate carefully when it arrives. If you find damage, document it and have the damage recorded on the bill of lading \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore signing for the shipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A clean signed bill of lading is generally the carrier's record that the equipment arrived without visible damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe recorded warranty is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 year for consumer use and 1 year for commercial use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e as standard. An extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-Year Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available when the unit is commissioned through a Quincy-authorized startup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThat authorized startup matters: it is a condition of the extended coverage, not simply an optional convenience. Coordinate it with the electrical installation so the compressor is commissioned correctly from day one.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a problem does occur, stop the machine and contact us before attempting repairs. Opening the compressor or having unauthorized work performed can complicate a warranty claim, so give us the opportunity to troubleshoot the issue first.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_8a3a8584-0b36-489a-8b13-5515099ee0e9.pdf?v=1788314571\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45946503921717,"sku":"4152021980","price":14485.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152021980__40588.1679848182.1280.1280.png?v=1788032005"},{"product_id":"quincy-air-compressor-10-hp-120-gallon-two-stage","title":"Quincy Air Compressor 10 HP 120 Gallon Two Stage","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QP Pro 10 HP reciprocating air compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e uses a fully pressure-lubricated, cast iron two-stage pump with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003espin-on oil filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving it a key maintenance advantage over splash-lubricated compressors. The pump is rated to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and runs from a 230V three-phase supply, while the horizontal 120-gallon-style tank configuration keeps the overall machine at approximately 78\" L × 28\" W × 55\" H. Note: published materials list two different model codes—5103DS12HCA23 and 3103DS12HCA23—so confirm the exact build before ordering if a specific model number appears on your quote or purchase order.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efull-flow oil filtration system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e continuously removes wear particles from the circulating lubricant, helping keep the oil cleaner throughout the service interval and protecting internal pump components from abrasive contamination. The spin-on filter can be replaced quickly without specialized tools, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides an easy way to check the lubricant level during routine maintenance. Published information conflicts on whether a low-oil-pressure shutdown is included, so that feature should be confirmed before purchase if it is important to your application.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe horizontal configuration is a practical choice for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eshops with limited ceiling height\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including bays beneath mezzanines, low roofs, or overhead door tracks. Its approximately 55\" overall height keeps service points accessible at standing level, while the 78\" length makes it better suited to facilities with available wall or floor space. With an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850-lb operating weight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and 230V three-phase electrical requirement, the QP Pro is a strong fit for professional automotive shops, service facilities, and other applications requiring a durable two-stage compressor with straightforward long-term maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe case for lying down\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA horizontal receiver solves a ceiling-height problem, not a floor-space problem. At about 55 inches tall, this machine can fit beneath a mezzanine, under a low roof, or in a bay where a vertical tank would interfere with an overhead door track. It also puts the service points closer to working height — the drain, sight glass, filter, belt guard and outlet are all within easier reach, which makes routine maintenance more convenient.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe trade-off is footprint. At 78 inches long, it requires a substantial strip of floor space, typically along a wall. If your building is short on floor space rather than ceiling height, the vertical version of this compressor may be the better choice.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAirflow, and a rule we keep\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe manufacturer's specification lists a delivered-air figure at 175 PSI, but does not attach a unit of measure to the published number. We do not put performance figures on the page when we cannot verify exactly what they represent. For that reason, there is no airflow number listed here.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your application is close to the compressor's capacity — particularly if you are sizing it around a specific tool list — ask us before ordering. We can confirm the applicable performance figure in writing for this build rather than have you make an important sizing decision from an ambiguous specification.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSiting and supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInstall the compressor on level, solid concrete with sufficient clearance for cooling airflow and routine service. Plan the route into the building before delivery: at nearly 6½ feet long, this is a machine that needs a clear approach through the doorway, not a last-minute attempt to maneuver around a tight corner.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe unit weighs approximately 850 lbs. Confirming that the floor, clearances and access route are suitable is the customer's responsibility, but it only takes a tape measure and a few minutes to verify before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eElectrical supply is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V, 3-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a magnetic starter fitted. Quincy does not publish a specific breaker size; its specification directs customers to consult a certified electrician. The appropriate conductor and breaker sizing depends on factors including the installation's run length and applicable local electrical code, so have the electrical requirements confirmed before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003e5103DS12HCA23 (a second code is also published - see above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP, 230 Volt, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive, cast iron cylinders with aluminum head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eFully pressure lubricated with spin-on oil filter and sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLow oil shutdown\u003c\/th\u003e\n\u003ctd\u003eDisputed - confirm with us before you order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003e120 gallon, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e3\/4 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e78 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e28 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e55 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003ePerfect For\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops that keep equipment for years\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and treat oil changes as scheduled maintenance rather than something to put off.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLow-ceiling buildings\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where a vertical receiver simply will not fit.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIndependent workshops with 230V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e already available.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWork areas where the compressor needs regular access\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing routine service without having to move the machine.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWhat Is In The Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor arrives assembled, with the pressure-lubricated two-stage pump, motor, belt drive and belt guard mounted on the 120-gallon horizontal receiver. The magnetic starter, spin-on oil filter and oil sight glass are already fitted, and warranty documentation is included with the shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYou will need to provide the electrical feed and disconnect, piping beyond the 3\/4-inch tank outlet, downstream filtration or drying if required for your application, isolation pads, and replacement oil and filters for future maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe manufacturer's certification record for this unit identifies an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME-rated tank\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA marks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Those certifications describe the equipment as manufactured and supplied from the factory.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThey do \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e certify your installation. Whether the electrical supply, disconnect, protection, ventilation and surrounding installation meet local code must be determined by a licensed electrician and, where applicable, the local authority having jurisdiction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your insurer, inspector or other authority requires specific compliance documentation, ask us before ordering. We would rather obtain the documentation in advance than have a paperwork issue appear during installation or sign-off.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFreight is available to the lower 48 states, with the shipping cost calculated at checkout based on the ZIP code entered. Residential delivery carries an additional residential fee. A commercial address with a loading dock or forklift will generally make unloading easier, while terminal pickup may be the most practical option for some locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eUnloading is the customer's responsibility.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The carrier delivers the approximately 850-lb machine to the designated delivery point; moving it from there requires suitable equipment such as a forklift, loading dock, or properly arranged terminal pickup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the shipment before accepting it and document any visible damage on the delivery paperwork.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis model includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The warranty documentation supplied with the compressor defines the coverage, exclusions and any registration requirements. If you want to review those terms before ordering, ask us and we can provide the applicable documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf something fails, contact us \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore dismantling or attempting repairs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Opening the pump, motor or starter can complicate a warranty claim even when the underlying fault appears obvious. Keep all removed parts and document the issue with photographs so the claim can be evaluated properly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45946508607541,"sku":"2020040899","price":7626.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3103DS12HCA23__72763.1679849703.1280.1280.webp?v=1788032562"},{"product_id":"quincy-air-compressor-10-hp-120-gallon-two-stage-208v-3-phase","title":"Quincy Air Compressor 10 HP 120 Gallon Two Stage 208V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QP MAX 10 HP two-stage compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is built for shops that need continuous air production rather than a machine that has to stop and cool down. The 5103D12HCA20M combines a heavy-duty cast-iron pump with aluminum heads, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,750 RPM industrial motor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and a 120-gallon horizontal receiver. Quincy rates the pump for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emore than 60,000 hours of life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the 100% duty cycle allows continuous operation under demanding workloads. The unit runs on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, measures 78\" L × 28\" W × 55\" H, and weighs 850 lbs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eslow 1,750 RPM pump speed\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps reduce piston speed, heat, and wear compared with faster reciprocating designs. Inside, stainless steel reed valves with bumpers handle repeated cycling, while the fin-and-tube intercooler reduces air temperature between compression stages. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003espin-on oil filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e continuously removes abrasive particles from the lubricant, and the low-oil shutdown protects the pump if lubrication drops below the required level. The magnetic starter adds motor thermal overload protection, helping the compressor shut down when a problem occurs instead of allowing a fault to damage the machine.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe QP MAX is a strong fit for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebusy automotive repair shops, fabrication facilities, agricultural operations, municipal workshops, and other environments with sustained compressed-air demand\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Its horizontal receiver is particularly useful where ceiling height is limited, while the 175 PSI maximum working pressure and 3\/4\" tank outlet support demanding shop applications. Plan for service clearance around the belt guard, oil sight glass, filter, and cooling fan, and have a certified electrician size the electrical connection based on your actual 208V three-phase service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat a 100% Duty Cycle Rating Actually Means\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDuty cycle is one of the most misunderstood figures in compressor specifications. A machine with a 50% duty rating is designed to run for part of a given period and then have time to cool down. Put two people on sanders and it can quickly be pushed beyond that intended cycle, increasing heat and oil degradation long before the compressor actually loses pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e means the compressor is designed for continuous operation without a mandatory rest period. The pump's cooling system, bearing loads and lubrication system are all designed around that workload. In a busy shop, that distinction matters: the compressor can keep up with sustained demand instead of relying on downtime to recover.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Shaft Speed Is the Number to Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe motor runs at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,750 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and that relatively low speed is intentional. In a reciprocating compressor, piston speed affects ring temperature, ring temperature affects wear, and wear ultimately affects pump life. Lower shaft speed reduces the mechanical and thermal stress placed on those components, which is why two compressors with similar capacity ratings can have very different designs and expected service lives.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe slower-running pump also produces a less aggressive operating sound, which can be an advantage when the compressor shares a building with people.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eheavy-duty cast-iron construction with aluminum heads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, along with graphite cylinder and head gaskets. Stainless-steel reed valves with bumpers are designed to withstand the repeated opening and closing cycles of continuous operation. A high-efficiency fin-and-tube intercooler reduces air temperature between stages, helping the second stage receive cooler, denser air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Protection Package\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eContinuous-duty operation leaves little room for small faults to become big ones, which is why several protective components are built into the package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides motor thermal overload protection, disconnecting the contactor when current exceeds the motor's intended operating range. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil shutoff\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e stops the compressor if the oil level becomes unsafe, helping prevent operation without adequate lubrication. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003espin-on oil filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps keep contaminants out of the lubrication system and away from critical pump components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTogether, these systems are designed to prevent a developing problem from becoming a catastrophic failure. In other words, the goal is for the compressor to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estop when something is wrong rather than keep running until something breaks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWill It Fit?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e measuring 78 inches long, 28 inches wide and 55 inches high, with a dry weight of approximately 850 lbs. Don't plan around the machine's dimensions alone. Leave sufficient service clearance so the belt guard, oil sight glass and filter can be reached without moving the compressor, and make sure the cooling fan has adequate access to unrestricted room air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tank outlet is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3\/4 inch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the maximum working pressure is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical supply is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V, 3-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the magnetic starter included. Do not assume your existing shop power is compatible simply because you already have three-phase equipment; three-phase systems are available at multiple voltages, and they are not interchangeable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy does not specify a universal breaker or conductor size for this installation. Its guidance is to have a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecertified electrician\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e determine the requirements based on your actual electrical service and run length. That's the right approach because those requirements depend on the installation rather than the compressor alone.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eBefore ordering, verify the electrical supply, doorway dimensions, access route, floor capacity and required service clearance. Those installation checks are the buyer's responsibility — and much easier to resolve with a tape measure before delivery than with an 850-lb compressor sitting in the wrong place.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo and three-bay service shops\u003c\/strong\u003e where the compressor is expected to keep up with everybody at once.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFabrication and metal finishing\u003c\/strong\u003e, where continuous-draw tools punish a duty-limited machine.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgricultural and municipal workshops\u003c\/strong\u003e running long unattended sessions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAny shop replacing a compressor that got hot\u003c\/strong\u003e rather than one that wore out — that is a duty cycle problem, and this is the answer to it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Arrives\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou get the compressor assembled: two-stage cast-iron pump and motor on the horizontal receiver, with the magnetic starter, the spin-on oil filter, the stainless steel reed valves, the graphite gaskets and the fin and tube intercooler all fitted at the factory. The documentation we hold does not list oil, hose, air treatment, a dryer, a regulator or an isolation valve as included, so budget for those separately, and tell us in advance if any of them decides your commissioning date.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP, 208V, 3-phase, 1750 RPM, magnetic starter fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty\u003c\/th\u003e\n\u003ctd\u003e100% continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage belt drive, heavy-duty cast iron with aluminum heads, spin-on oil filter, low oil shut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValves and sealing\u003c\/th\u003e\n\u003ctd\u003eStainless steel reed valves with bumpers, graphite cylinder and head gaskets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eHigh-efficiency fin and tube intercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal, 3\/4-inch outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall size\u003c\/th\u003e\n\u003ctd\u003e78 inches long, 28 inches wide, 55 inches high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory, extending to the 3-year No Bull cover on registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eTwo Details to Confirm Before You Order\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTwo specifications are reported differently across the published sources, so we are flagging both rather than guessing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eHow the pump is lubricated.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The manufacturer's feature list and the description on this page identify the compressor as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efully pressure-lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a positive-displacement oil pump supplying the crankshaft, bearings and connecting rods. However, the specification data lists the lubrication system as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These describe two different lubrication systems, so they should not be treated as interchangeable wording.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThe tank drain.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e There is a similar discrepancy regarding the tank drain. The feature list and specification table indicate that an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic electronic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is included, while another specification line states that it is not.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specification sheet records \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME, UL and CSA marks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The ASME certification applies to the pressure vessel — including its design, materials and construction — while the electrical certifications apply to the applicable motor and control components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese certifications do not certify the quality of the compressed air, replace local permitting requirements, or eliminate any inspection or recertification requirements that may apply to pressure vessels in your jurisdiction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore installation, confirm the requirements with the applicable local authority, workplace inspector or insurer. It is much easier to address compliance requirements before the compressor is installed than afterward.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor ships by freight within the lower 48 states, with shipping calculated at checkout based on the delivery address rather than averaged into the product price.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eArrange unloading \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore the compressor ships\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. At approximately 850 lbs, this is not a shipment that a driver and customer can safely move by hand. Plan for a forklift or loading dock at the delivery location. If neither is available, terminal pickup may be the more practical option, and we can help arrange it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBe sure to identify the address as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eresidential\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when applicable. Carriers charge a separate residential-delivery fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen the compressor arrives, inspect the shipment carefully before signing the delivery paperwork. Check for bent guards, damaged gauges, oil leaks or marks on the receiver that could indicate contact with handling equipment. If you find damage, document it and have it recorded on the bill of lading \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ewhile the driver is present\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe standard coverage is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty from Quincy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The published terms also identify an extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year No Bull warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when the compressor is registered with Quincy and maintained using qualifying Quincy maintenance kits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete the registration promptly after delivery rather than leaving it until later. If the extended coverage is conditional on registration and maintenance requirements, those requirements should be followed from the start.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAnd if a warranty issue occurs, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before opening the pump, motor or starter or attempting repairs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Do not dismantle the equipment before the claim has been evaluated. Keeping the machine intact, retaining removed parts if any work has already been performed, and documenting the issue gives the manufacturer the best opportunity to assess the claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45951997280309,"sku":"2020040906","price":9451.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3103D12HCA20M__94293.1679861409.1280.1280.png?v=1788124987"},{"product_id":"quincy-air-compressor-120-gallon-460v-3-phase","title":"Quincy Air Compressor 120 Gallon 460V 3 Phase","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy QP MAX 15 HP\u003c\/strong\u003e is the 460V three-phase version for shops that already have the right electrical service in place. It combines a two-stage cast-iron pump with a \u003cstrong\u003e120-gallon horizontal receiver\u003c\/strong\u003e and a listed \u003cstrong\u003e21-amp draw at 460V\u003c\/strong\u003e, reducing the conductor, conduit, breaker, and disconnect requirements compared with lower-voltage versions of the same compressor. The 78\" × 28\" × 55\" footprint works well in installations with limited ceiling height. Note: electrical sizing and installation should be handled by a certified electrician based on your actual service, run length, and local code.\u003c\/p\u003e\n\u003cp\u003eThe two-stage pump uses \u003cstrong\u003ecast-iron construction, aluminum heads, and a fin-and-tube intercooler\u003c\/strong\u003e to manage heat between compression stages. A mounted air-cooled aftercooler further reduces discharge temperature before air reaches the tank, helping moisture condense closer to the compressor. For lubrication and protection, the system includes a \u003cstrong\u003espin-on oil filter, positive-displacement gerotor oil pump, oil sight glass, and low-oil shutoff\u003c\/strong\u003e. Stainless steel reed valves with bumpers are designed for repeated cycling, while the 1\" tank outlet provides a substantial connection point for the shop's air system.\u003c\/p\u003e\n\u003cp\u003eThe QP MAX is a practical choice for \u003cstrong\u003eindustrial facilities, multi-bay automotive shops, fabrication operations, and manufacturing sites already equipped with 460V three-phase power\u003c\/strong\u003e. Its 995-lb weight calls for appropriate handling equipment and a level concrete slab, while the horizontal receiver makes it easier to work beneath lower ceilings than a comparable vertical configuration. If your facility uses single-phase power or three-phase service at a lower voltage, choose the QP MAX version designed for that supply rather than adding a transformer solely for the compressor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 78\" long by 28\" wide, plus the clearance needed for service and airflow. Treat the published dimensions as the machine's footprint, not the complete installation space.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 55\" to the top. Leave adequate clearance above the cooler for airflow and enough room around the tank and safety valve for inspection and service.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 995 lbs. Plan for a level concrete slab and appropriate mechanical equipment to position the compressor safely.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 460V, three-phase, with a listed current draw of 21 A. Quincy does not publish a specific breaker size for this unit and directs buyers to consult a certified electrician. The correct breaker and conductor sizing depend on the actual run length, installation conditions and applicable local code.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\" tank outlet, providing a substantial connection point for the shop's compressed-air piping.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe foundation, electrical feed, disconnect and connection to the compressed-air main are the customer's responsibility. Installation should be completed by appropriately licensed tradespeople in accordance with local requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Pump: Iron, Two Stages, and Filtered Oil Supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron construction with aluminum heads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and compresses air in two stages. A high-efficiency fin-and-tube intercooler between the stages cools the air before it enters the second stage, reducing thermal stress and improving compression efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStainless-steel reed valves with valve bumpers manage the intake and discharge cycles, while a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egerotor positive-displacement oil pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and spin-on oil filter provide the lubrication system. An oil sight glass makes the oil level easy to monitor, and a low-oil shutoff helps protect the pump if lubrication falls below a safe level.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDownstream of the pump, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emounted air-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduces discharge temperature before the compressed air reaches the receiver. That helps more moisture condense at the compressor rather than farther downstream in the shop's air piping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIndustrial and light-manufacturing facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that already have 460V, three-phase service.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMulti-bay service centers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where several technicians may be using compressed air simultaneously.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e running sanders, grinders and plasma equipment for extended periods.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities replacing an aging three-phase compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where the existing electrical feed and disconnect are already properly sized.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your building has single-phase power or three-phase service at a different voltage, this configuration is not the right match. The compressor family is available in versions designed for other electrical supplies, so match the compressor to the service available at the installation site.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package arrives as a complete, assembled compressor system consisting of the \u003c\/span\u003etwo-stage cast-iron pump, motor, 120-gallon horizontal receiver, magnetic starter, mounted air-cooled aftercooler, fin-and-tube intercooler, spin-on oil filter and oil sight glass.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e460V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw (as listed by Quincy)\u003c\/th\u003e\n\u003ctd\u003e21 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum heads, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e78\" long × 28\" wide × 55\" tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e995 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory warranty, extending to 3 years (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur records identify the receiver as built to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME pressure-vessel code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e among the unit's marks. Those certifications should be read specifically for what they cover: an ASME pressure-vessel certification applies to the tank, while a mark on the overall assembly does not necessarily satisfy every certification or listing requirement imposed by a local authority.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInsurers, fleet operators and certain jurisdictions may have specific requirements for permanently installed equipment. If that applies to your installation, verify the required listing or certification against the unit's data plate before purchase. We would rather resolve the question before the compressor ships than have it become an issue during inspection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBefore You Order — Please Confirm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA few specifications are reported differently across the available documentation. Rather than guess, we recommend confirming the following before ordering:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLubrication.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published descriptions of the oil system differ. The package name and feature list identify the compressor as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efully pressure-lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while a specification field records it as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. If the lubrication system is an important factor in your purchase, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm it with us in writing before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. We will obtain the answer directly from Quincy.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic tank drain.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The published information also differs on the tank drain. The description and one specification record indicate that an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic automatic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is fitted, while another specification states that it is not. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAsk us to confirm the configuration before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e if you are relying on an automatic drain.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDelivered air volume.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No CFM figure is published on this page because the available figure for this build is not accompanied by a verifiable unit of measure. Contact us and we will obtain the applicable factory figure.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePump speed.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No pump speed is published for this specific 460V configuration, so we have not substituted a figure from another model. Quincy documents lower pump speeds for related configurations at other voltages, but those figures should not be treated as specifications for this build. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAsk us and we will confirm the correct pump speed.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the current freight cost calculated at checkout for your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e995 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the compressor will arrive on a freight truck and the customer is responsible for unloading it. Plan for a suitable forklift or loading dock, or arrange terminal pickup if the delivery location cannot accommodate the shipment. Residential addresses are subject to an additional residential-delivery fee, which will be reflected in the freight quote at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the machine before accepting the shipment. Check the receiver, feet, guards, gauges and other exposed components for signs of shipping damage. If you find damage, document it and have it recorded on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading before signing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the option to extend coverage to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e subject to the terms and conditions in Quincy's warranty handbook.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe warranty handbook controls the actual coverage, exclusions and requirements, so review those terms before relying on the extended warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a fault occurs, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before anyone opens or dismantles the pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Unauthorized disassembly or repair can affect warranty eligibility. Keep the compressor intact until the manufacturer or authorized service provider has had an opportunity to evaluate the problem and advise on the next step.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45951997607989,"sku":"2020040920","price":11262.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3153D12HCB46M__96761.1679838533.1280.1280.png?v=1788125762"},{"product_id":"quincy-air-compressor-120-gallon-two-stage","title":"Quincy Air Compressor 120 Gallon Two Stage","description":"\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eQuincy QP Pro 10 HP two-stage compressor\u003c\/strong\u003e is built around the components that do the most repetitive work inside a reciprocating pump: its \u003cstrong\u003estainless steel reed valves with valve bumpers\u003c\/strong\u003e. The valves flex with every revolution, while the bumpers cushion their movement to reduce impact and fatigue. Cast iron cylinders, aluminum heads, and \u003cstrong\u003egraphite cylinder and head gaskets\u003c\/strong\u003e add heat-resistant construction around the valve assembly. The compressor uses a 120-gallon vertical receiver rated to \u003cstrong\u003e175 PSI\u003c\/strong\u003e and operates on 230V three-phase power. Note: the approximately 75\" overall height requires adequate ceiling and delivery access.\u003c\/p\u003e\n\u003cp\u003eThe fully pressure-lubricated bottom end uses a \u003cstrong\u003eGerotor positive-displacement oil pump\u003c\/strong\u003e to feed the crankshaft, bearings, and connecting rods. Unlike splash lubrication, this system allows the oil to pass through a \u003cstrong\u003espin-on filter\u003c\/strong\u003e, continuously removing contaminants before they circulate through the pump. An oil sight glass makes routine level checks quick, while the belt-drive layout keeps common service points accessible. The graphite gaskets also help maintain a reliable seal through repeated heat cycles, supporting consistent compression and reducing the gradual pressure loss associated with gasket deterioration.\u003c\/p\u003e\n\u003cp\u003eThe QP Pro is suited to \u003cstrong\u003eprofessional automotive shops, service facilities, fabrication operations, and other workshops\u003c\/strong\u003e that need a durable two-stage compressor for regular compressed-air use. Its vertical receiver keeps the floor footprint to roughly 40\" × 30\", making it easier to fit along a wall, but the approximately 75\" height makes ceiling clearance important. The unit requires \u003cstrong\u003e230V three-phase power\u003c\/strong\u003e and includes a magnetic starter; have a certified electrician determine the appropriate breaker and conductor sizing for your installation. Because the available airflow specification is not accompanied by a verifiable unit, it should be confirmed for the exact build before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eValves, Bumpers and Gaskets — The Unglamorous Part\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA reed valve is a thin, flexible strip of steel with no bearings and no adjustment points. It opens under pressure and snaps closed again through millions of operating cycles. Two things eventually work against it: fatigue at the flex point and impact when the reed reaches the end of its travel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eStainless steel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps resist fatigue and maintains its spring characteristics in the hot, humid environment around the cylinder. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eValve bumpers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e address impact by cushioning the reed as it opens and closes, reducing the repeated metal-to-metal shock that can accelerate wear.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNeither feature is exotic, but both contribute to maintaining valve performance over the long term.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egraphite cylinder and head gaskets\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e serve a similar purpose. Graphite handles repeated heat cycling better than many conventional composite gasket materials, helping maintain a reliable seal around the valve plate. A deteriorating head gasket may not produce an obvious failure; it can instead show up gradually as lost efficiency and reduced available pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Lubrication Underneath\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBelow the valve deck, this machine uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efully pressure-lubricated system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A Gerotor positive-displacement oil pump supplies oil to the crankshaft, bearings and connecting rods rather than relying solely on splash lubrication inside the crankcase.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause the oil is circulated under pressure, it can also pass through a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003espin-on oil filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping remove contaminants before they reach critical components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a quick way to check the oil level. Combined with the spin-on filter and belt-drive arrangement, the system is designed around straightforward routine maintenance that can be handled as part of normal shop service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAirflow: What We Will and Will Not Print\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur specification record contains a delivered-air figure for this pump at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, but the figure is recorded without a unit of measure. We do not publish a performance number that we cannot independently verify from the available documentation, so there is no airflow figure listed on this page.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf compressor sizing is close for your application or tool list, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. We will confirm the applicable factory airflow figure for this exact configuration in writing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit, and What About the Electrical Supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis configuration uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003evertical receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, keeping the floor footprint relatively compact at approximately 40 inches by 30 inches. The trade-off is height: the unit stands approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e75 inches tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs about \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, check the available ceiling height as well as every doorway, shutter and overhead track along the route from the delivery point to the installation location. The installation area should have a level, solid floor with adequate clearance around the compressor for cooling airflow and access to service points such as the drain and oil sight glass.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eVerifying the floor, clearances and access route is the customer's responsibility. A few minutes with a tape measure before delivery can prevent a very expensive installation problem later.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical supply is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V, 3-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a magnetic starter fitted. Quincy does not publish a specific breaker size and directs customers to consult a certified electrician. The appropriate conductor and breaker sizing depends on the actual installation, including the length of the electrical run and applicable local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHave the electrical requirements confirmed before the compressor arrives rather than assuming an existing three-phase circuit will be suitable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003e5103DS12VCA23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP, 230 Volt, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump type\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive, cast iron cylinders with aluminum head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValves\u003c\/th\u003e\n\u003ctd\u003eStainless steel reed valves with valve bumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGaskets\u003c\/th\u003e\n\u003ctd\u003eGraphite cylinder and head gaskets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eFully pressure lubricated, Gerotor pump, spin-on filter, sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003e120 gallon, vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e3\/4 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFloor space\u003c\/th\u003e\n\u003ctd\u003e40 inches by 30 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall height\u003c\/th\u003e\n\u003ctd\u003e75 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003ePerfect For\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops with sustained air demand\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — sanding, blasting or paint-booth applications — where reliable valve performance matters over long operating periods.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWorkshops with 230V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e already available and properly configured for the compressor.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTight floor plans\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where a vertical receiver is the practical way to get 120 gallons of storage capacity into the available space.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOwners who expect to keep their equipment for years\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with routine maintenance treated as part of the cost of ownership.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis configuration is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot intended for single-phase service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. If your building does not have compatible three-phase power, the compressor cannot simply be adapted with a basic plug or voltage converter. Choose a configuration that matches the electrical service available at the installation site.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat Is in the Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is delivered \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efactory assembled\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the two-stage pump, stainless-steel reed valves, graphite gaskets, motor, belt drive and belt guard mounted on the 120-gallon vertical receiver. The magnetic starter, spin-on oil filter and oil sight glass are fitted, and warranty documentation is included with the unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYou will need to supply the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectrical feed and disconnect\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, piping downstream of the 3\/4-inch tank outlet, downstream filtration or drying if required for your application, anti-vibration pads, and replacement oil and filters for future maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe certification record for this compressor identifies an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME-rated tank\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA marks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These certifications describe the equipment as manufactured and evaluated by the applicable certification bodies.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThey do not certify the installation. Whether the electrical supply, disconnect, protection, ventilation and other installation details meet local requirements must be determined by a licensed electrician and, where applicable, the local authority having jurisdiction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your insurer, inspector or other authority requires specific compliance documentation, request it before purchase. We can obtain the applicable documentation from the manufacturer rather than leaving a compliance question until after installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFreight is available to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the shipping cost calculated at checkout based on the ZIP code and delivery address you provide. Residential deliveries are subject to an additional residential fee. Commercial delivery locations equipped with a suitable dock or forklift may be more practical, while terminal pickup is another option when the destination cannot accommodate freight unloading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan the unloading arrangements in advance. The carrier's delivery point and available services depend on the shipment, but an approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850-lb compressor requires appropriate mechanical handling equipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Arrange a forklift, loading dock or terminal pickup rather than relying on manual unloading.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the shipment before signing for delivery. Check the crate, receiver, pump, motor, guards and gauges for visible damage. If you find any damage, document it and have it recorded on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis model includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The warranty documentation supplied with the compressor defines the coverage, exclusions and any registration requirements. If you would like to review the applicable terms before ordering, ask us and we can provide the documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a problem occurs, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before opening, dismantling or attempting repairs on the pump, motor or starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Unauthorized disassembly can affect warranty eligibility. Keep the components intact, retain any removed parts and photograph the issue so the manufacturer can properly evaluate the claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45951998328885,"sku":"2020040788","price":7833.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3103DS12VCA23__14219.1679860738.1280.1280.webp?v=1788126732"},{"product_id":"quincy-air-compressor-120-gallon-two-stage-230v-3-phase","title":"Quincy Air Compressor 120 Gallon Two Stage 230V 3 Phase","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy QP Pro 15 HP two-stage compressor\u003c\/strong\u003e is built for long-term service, with replaceable wear components instead of sealed assemblies that force replacement when they wear out. Its \u003cstrong\u003estainless steel reed valves and valve bumpers\u003c\/strong\u003e, spin-on oil filter, graphite gaskets, and gerotor oil pump are all serviceable components, while Quincy rates the pump for \u003cstrong\u003e60,000+ hours of life\u003c\/strong\u003e. The 1,750 RPM cast-iron pump sits on a 120-gallon horizontal receiver rated to \u003cstrong\u003e175 PSI\u003c\/strong\u003e and runs on 230V three-phase power. Note: this unit draws 42A, so electrical installation should be planned with a licensed electrician before delivery.\u003c\/p\u003e\n\u003cp\u003eThe lubrication system is designed for routine service rather than complicated rebuilds. A \u003cstrong\u003epositive-displacement gerotor oil pump\u003c\/strong\u003e circulates lubricant through the system and allows filtration through a spin-on cartridge, while the oil sight glass makes level checks straightforward. Stainless steel reeds handle the repeated cycling inside the pump, with valve bumpers limiting their movement and helping reduce fatigue. A \u003cstrong\u003efin-and-tube intercooler\u003c\/strong\u003e manages heat between compression stages, while the mounted air-cooled aftercooler lowers discharge temperature before air enters the tank. Together, these systems help protect the pump's highest-wear components and support consistent operation over years of use.\u003c\/p\u003e\n\u003cp\u003eThe QP Pro is a strong fit for \u003cstrong\u003ebusy automotive workshops, tire and fleet service bays, paint and body operations, and shops that prefer maintaining equipment rather than replacing it\u003c\/strong\u003e. Its horizontal 120-gallon receiver measures 78\" × 28\" × 55\" and weighs 995 lbs, so plan for a level slab, adequate service clearance, and appropriate handling equipment. The 1\" tank outlet provides a substantial connection point for the shop air main. This model requires \u003cstrong\u003e230V three-phase power\u003c\/strong\u003e and is not intended for single-phase installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReed Valves and Why They Matter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIn a reciprocating compressor, the valves open and close on every stroke, operating through millions of cycles in a hot environment where oil mist and compressed air are present. That makes valve durability an important part of long-term pump performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eStainless-steel reed valves\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e are designed to resist the heat and fatigue associated with repeated cycling, while \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003evalve bumpers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e limit reed travel and help reduce stress at the flex point. The pump also uses a fin-and-tube intercooler to reduce the temperature of the air between compression stages and a mounted air-cooled aftercooler to lower discharge temperature before the air reaches the receiver.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe goal is straightforward: control operating temperatures and reduce the stresses placed on the valve system during repeated operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiltered Oil, Not Just Oil\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe lubrication system uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eGerotor positive-displacement oil pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which supplies a controlled flow of lubricant to the pump's critical components. The oil passes through a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003espin-on oil filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping remove contaminants before they circulate through the lubrication system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe spin-on design also simplifies routine filter replacement. An \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a quick visual check of the oil level, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil shutoff\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides additional protection by stopping the compressor if the oil level falls below a safe operating point.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFloor.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 78\" long by 28\" wide on a level slab. Allow additional working clearance at the service points, including the drain, oil fill and belt guard.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOverall height.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 55\".\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 995 lbs, delivered on a pallet.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eElectrical supply.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230V, three-phase. Quincy lists a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e42 A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e current draw for this configuration but does not publish a specific breaker size, instead directing buyers to consult a certified electrician. Follow that guidance: conductor length, ambient conditions, installation requirements and local electrical code all affect the appropriate protection and conductor sizing.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDischarge.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\" tank outlet.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe foundation, electrical feed, disconnect and connection to the shop's compressed-air main are the customer's responsibility. Electrical installation should be completed by a properly licensed electrician in accordance with applicable local requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure and Storage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The higher tank rating provides additional storage capacity at pressure, while the downstream air system can be regulated to the pressure required by individual tools.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA larger stored-air reserve can help reduce how frequently the compressor needs to cycle when demand fluctuates and provides additional reserve capacity when multiple users draw air simultaneously. The actual performance of the system still depends on compressor output, operating pressure, tool demand and the shop's piping configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBusy independent workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with compatible 230V, three-phase service.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTire shops and fleet bays\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with sustained compressed-air demand.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePaint and body operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that require a steady supply of properly treated compressed air.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops that perform their own routine maintenance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and prefer equipment with accessible, serviceable components.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis configuration is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot suitable for single-phase electrical service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Confirm the voltage and phase available at your installation site before ordering. Selecting the correct electrical configuration before delivery is far easier than trying to resolve an incompatible power supply afterward.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efully assembled compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a cast-iron two-stage pump, aluminum heads, motor, 120-gallon horizontal receiver, magnetic starter, mounted air-cooled aftercooler, high-efficiency fin-and-tube intercooler, spin-on oil filter, stainless-steel reed valves and oil sight glass.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eNo air dryer is included.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eShop piping, downstream filtration, regulators, the electrical disconnect and electrical feed are not supplied. When the compressor arrives, check the shipment against the packing list to confirm the contents before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e230V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw (as listed by Quincy)\u003c\/th\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum heads, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump speed\u003c\/th\u003e\n\u003ctd\u003e1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValves\u003c\/th\u003e\n\u003ctd\u003eStainless steel reed with valve bumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e78\" long × 28\" wide × 55\" tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e995 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory warranty, extending to 3 years (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur records identify the receiver as built to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME pressure-vessel code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e among the unit's marks. These are separate certifications: an ASME pressure-vessel designation relates to the construction and testing of the receiver, not necessarily to the complete compressor assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInsurers, fleet operators and local authorities may have specific requirements for permanently installed equipment, and a certification or listing accepted by one organization may not satisfy another. If a particular listing is required for your insurance, workplace or local code, verify it against the unit's data plate before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBefore You Order — Please Confirm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA few published specifications differ across our available records. Rather than guess, we recommend confirming the following before ordering:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLubrication method.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The package is described as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efully pressure-lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the feature list states the same. However, one specification field in our catalogue records the oil system as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. We cannot resolve that discrepancy from the information currently available, so we will not present either description as confirmed. If the lubrication method matters to your purchase, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us and we will obtain the factory answer from Quincy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eElectronic tank drain.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Two records indicate that an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic electronic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is included, while another states that it is not. If you require a factory-fitted automatic drain, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm the configuration with us before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rather than assuming it is included.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir delivery.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No CFM figure is published on this page. The value in our records is not accompanied by a unit of measure that we can verify, and an airflow rating is too important to guess. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAsk us and we will obtain the applicable factory rating.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to addresses within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the current freight cost calculated at checkout based on your ZIP code and delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e995-lb palletized machine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e arriving by freight truck. Arrange suitable unloading equipment in advance, such as a forklift or loading dock, or choose carrier-terminal pickup if that better suits your location.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential deliveries are subject to an additional residential fee, which will be reflected in the freight quote at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore signing the delivery paperwork, inspect the shipment carefully. Walk around the pallet and check the receiver, feet, guards, gauges and cooler fins for visible damage. If you find anything wrong, document it and have the damage recorded on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading while the driver is present\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with coverage extendable to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e subject to the conditions specified by Quincy in its warranty handbook.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45952007307317,"sku":"2020040919","price":11262.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3153D12HCB23M__50600.1679862049.1280.1280.webp?v=1788128785"},{"product_id":"quincy-air-compressor-132-gallon-rotary-screw-value-package","title":"Quincy Air Compressor 132 Gallon Rotary Screw Value Package","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy 60.9 CFM rotary screw compressor\u003c\/strong\u003e delivers a combination that matters in a busy shop: \u003cstrong\u003e60.9 CFM at 71 dBA\u003c\/strong\u003e with a 100% duty cycle. That output is enough for demanding air tools and applications such as media blasting and production spray equipment, while the relatively low operating noise makes it practical to locate closer to the work area. Its compact airend uses gear drive, and the package includes a TEFC IP55 motor, Wye-Delta reduced-voltage starting, and synthetic lubricant rated for up to 8,000 hours. Note: the unit measures 74\" × 30.7\" × 72.2\" and weighs 1,184 lbs, so verify delivery access and installation clearance.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003egear-driven airend\u003c\/strong\u003e eliminates belts that require tensioning and can gradually lose efficiency as they wear. For continuous operation, that direct power transmission works alongside the 100% duty-cycle design to provide steady compressed air throughout the working day. A spin-on fluid filter, low-oil shutdown, hinged service doors, and detachable panels simplify routine maintenance. The package also includes an aftercooler to reduce discharge temperature and remove bulk moisture before air enters the shop system. Note that manufacturer records differ on whether this exact configuration includes an integrated refrigerated dryer, so confirm the current factory configuration before ordering if a built-in dryer is essential.\u003c\/p\u003e\n\u003cp\u003eThis compressor is well suited to \u003cstrong\u003ebusy multi-bay repair shops, fabrication facilities, and light-production environments\u003c\/strong\u003e where several air-consuming tools may operate throughout the day. It can also make sense for shops that already have downstream dryers and filtration and want a compact, quieter compressor package. The unit requires \u003cstrong\u003e208–230\/460V three-phase power\u003c\/strong\u003e; Quincy does not publish a fixed amp draw or breaker size for this build, so a licensed electrician should size the feeder and disconnect from the actual nameplate and installation conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Air Dryer Question on This Part Number\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThere is an important discrepancy in the published data for this package. The manufacturer's feature list identifies an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e“Integrated Refrigerant Air Dryer,”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and the description previously published on this page also described an integrated dryer. However, the specification table lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e“No”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the Air Dryer field.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe will not resolve that discrepancy by choosing the more attractive answer. If an integrated dryer is important to your purchase, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us before ordering and we will confirm the configuration against the current factory order sheet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhat the specification table does confirm is an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eaftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It cools the compressed air as it leaves the airend, allowing a significant amount of bulk moisture to condense before the air enters the downstream system. That is useful moisture control, but it is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot equivalent to a refrigerated air dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and should not be represented as one.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your shop already has a refrigerated dryer and appropriate filtration installed on the header, the built-in dryer question may not affect your decision. Either way, confirm the configuration before ordering rather than discovering the difference after delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGear Drive and Continuous Running\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe airend uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egear drive\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, transferring power from the motor to the screw element through hardened gears operating in the compressor's lubrication system. Unlike a belt-driven transmission, there are no drive belts to tension or matched belt sets to replace.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor a compressor expected to operate continuously, that arrangement removes one common source of routine drive maintenance. A deteriorating or slipping belt can gradually reduce transmission efficiency without producing an obvious failure, while a properly maintained gear drive provides a direct mechanical connection between the motor and airend.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe rest of the package follows the same continuous-duty philosophy. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePremium synthetic lubricant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is specified for up to 8,000 hours, helping support long service intervals and controlled oil carryover. The motor is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTEFC with IP55 protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing protection appropriate for demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eWye-delta reduced-voltage starting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps limit starting current and reduce the electrical impact of motor startup. A low-oil shutdown provides protection for the engine and pump, the fluid filter uses a spin-on design, and the hinged doors and detachable panels provide access for routine service without requiring extensive disassembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit, and Can Your Building Feed It?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e74 inches long × 30.7 inches wide × 72.2 inches high\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,184 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis is a relatively tall package rather than a particularly wide one, so check the full delivery route before the compressor arrives. Measure door openings, ceiling height and any overhead obstructions along the route from the unloading point to the final installation location. Once positioned, leave adequate working clearance around the service panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver outlet is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 inch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so size the downstream distribution piping appropriately from that connection point.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe electrical configuration requires particular attention. This is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208–230\/460V, 3-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e machine with a magnetic starter included. Quincy does not publish an amp draw or recommended breaker size for this model; both fields are listed as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e“Consult Certified Electrician.”\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe will not substitute an estimate for the manufacturer's specification. Have a licensed electrician size the service, feeder and disconnect from the actual nameplate and installation conditions before delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBusy multi-bay service shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need the compressor located within the working facility rather than isolated elsewhere.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication and light-production operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with sustained, all-day compressed-air demand.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops with existing air treatment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including dryers and filtration, that want the compressor and receiver supplied as a single package.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIndustrial facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that already have compatible three-phase electrical service.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e20 HP, electric, TEFC with IP 55 wash-down protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFree air delivery\u003c\/th\u003e\n\u003ctd\u003e60.9 CFM (see the caveat above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSound level\u003c\/th\u003e\n\u003ctd\u003e71 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e208-230\/460V, 3-phase, Wye-Delta start, magnetic starter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmp draw \/ breaker\u003c\/th\u003e\n\u003ctd\u003eManufacturer states \"Consult Certified Electrician\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, oil-lubricated, gear drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eFitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e132 gallon horizontal, 1 inch outlet, no electronic drain valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e74 in x 30.7 in x 72.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,184 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat's Included\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAccording to the manufacturer's feature list and specification table, the package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egear-driven QGS-20S rotary screw compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, Infologic2 Basic Controller with display panel, TEFC motor with IP55 wash-down protection, 132-gallon horizontal receiver, aftercooler, air filter, pressure gauge, oil sight glass, magnetic starter, low-oil shutdown and spin-on fluid filter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAn electronic drain valve is not included.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003erefrigerated air dryer remains the disputed item\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e described above. Until we confirm the current factory configuration, treat the dryer as unconfirmed rather than assuming it is included.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to addresses within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the current freight cost calculated at checkout based on your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe deliberately do not publish a fixed shipping figure because freight rates vary by destination and carrier. At this size and weight, unloading needs to be planned before shipment. Confirm that your location can accommodate the delivery, with a suitable loading dock or forklift with adequate capacity, or arrange pickup from the carrier's terminal if necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause the package is both heavy and relatively tall, check the unloading area and the entire route to the installation location before it ships. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eResidential deliveries are subject to an additional residential fee.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the shipment carefully before signing the delivery paperwork. Check the crate, receiver, panels, gauges and exposed components for visible damage. If you find damage, document it and have it recorded on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading while the driver is present\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe recorded standard warranty is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 year for consumer use and 1 year for commercial use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. An extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-Year Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies when the unit is commissioned through a Quincy-authorized startup, subject to the applicable warranty terms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause authorized startup is a condition of the extended coverage, arrange it as part of the installation rather than afterward.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a fault develops, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eshut the machine down and contact us before dismantling or attempting repairs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Opening the compressor can make it more difficult to establish the cause and timing of a failure and may affect warranty eligibility. Keep the unit intact until the claim has been evaluated and you have been advised on the appropriate next step.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45952010092597,"sku":"4152021996","price":13704.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152021972__73412.1679921471.1280.1280_6501b5e1-19ca-4002-b0dc-78f64b059430.jpg?v=1788129395"},{"product_id":"quincy-air-compressor-132-gallon-rotary-screw-with-dryer","title":"Quincy Air Compressor 132 Gallon Rotary Screw with Dryer","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy QGS-20S Value Package\u003c\/strong\u003e combines a rotary screw airend, \u003cstrong\u003e132-gallon horizontal receiver, and refrigerated air dryer\u003c\/strong\u003e into one factory-assembled system. The interconnecting piping, mounting, and control wiring are already matched and installed, eliminating the need to configure and connect separate compressor and dryer components. It delivers \u003cstrong\u003e60.9 CFM at 71 dBA\u003c\/strong\u003e on a 100% duty cycle, providing continuous air for demanding shop applications without the noise level typically associated with high-output equipment. Note: the assembled package measures 74\" × 30.7\" × 72.2\" and weighs 1,296 lbs, so verify delivery access and installation clearance.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eintegrated refrigerated dryer\u003c\/strong\u003e is the key advantage of this configuration. Air leaves the oil-injected twin-screw airend hot and saturated, while the aftercooler removes bulk moisture before the refrigerated dryer further reduces the dew point. That gives your shop cleaner, drier compressed air for tools and finishing equipment and reduces moisture-related problems throughout the air system. The 100% duty-cycle design supports continuous operation, while the factory-matched assembly avoids the extra pipework, connections, and installation coordination required when purchasing the components separately. Note: the published 60.9 CFM figure has a slight discrepancy with another product data field, so confirm the exact rating with Quincy if your application requires precise air-demand calculations.\u003c\/p\u003e\n\u003cp\u003eThis package is a strong fit for \u003cstrong\u003emulti-bay automotive and truck shops, body and paint operations, fabrication facilities, and light-production environments\u003c\/strong\u003e that need continuous, dry compressed air. It is particularly useful when you want the compressor, receiver, and dryer handled as a single integrated installation rather than separate equipment. The system requires \u003cstrong\u003e208–230\/460V three-phase power\u003c\/strong\u003e and includes a magnetic starter with Wye-Delta reduced-voltage starting. Quincy does not publish a fixed amp or breaker specification for this configuration, so have a licensed electrician size the electrical service, feeder, and disconnect from the machine nameplate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Numbers This Unit Will Actually Stand Behind\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOne of the useful things about this particular part number is how complete its published data is. It lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60.9 CFM of free-air delivery\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esound level of 71 dBA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — two specifications that are missing units or otherwise unclear in some related models. Here, you have meaningful numbers to work with when sizing the compressor and planning where it will operate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt 60.9 CFM, this is a substantial continuous air supply for a busy workshop. It is well suited to multiple pneumatic tools operating throughout the day and to applications with sustained air demand that can quickly overwhelm a reciprocating compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e71 dBA sound level\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is also worth noting if the compressor will be located near the working area. The enclosure helps make the unit more practical for shops where placing the compressor in a separate mechanical room is not an option.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThere is one qualification on the airflow figure. The marketing copy for this product lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60.9 CFM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the product specification data records a slightly different value for the same rating. The difference is fractional, but if you are sizing the compressor very close to a fixed equipment requirement, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us and we will confirm the exact rating against the current Quincy datasheet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rather than asking you to design around an unresolved discrepancy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Duty, and the Dryer That Goes With It\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is rated for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, meaning it is designed for continuous operation. Its oil-injected twin-screw airend uses the compressor fluid for both lubrication and cooling, supporting the demands of sustained operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eContinuous compression also produces continuous moisture. That makes the air-treatment package particularly important. The compressed air leaves the airend hot and saturated; the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eaftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e lowers its temperature and removes bulk moisture, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eintegrated refrigerated air dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e further reduces the moisture content to provide a controlled pressure dew point downstream.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProper air treatment can help prevent moisture-related problems throughout the distribution system and at the point of use, including corrosion in piping, water accumulation in air tools and contamination of finishing applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor this particular package, the dryer is not a disputed specification. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eThe title, feature list and specification table all identify the integrated refrigerated air dryer as included.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e That distinction matters because other configurations in this compressor family do not necessarily have the same air-treatment package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit, and Can Your Building Supply It?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe assembled package measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e74 inches long × 30.7 inches wide × 72.2 inches high\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,296 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis is the heaviest configuration in this cabinet family, reflecting the integrated receiver and dryer package. Check ceiling height, door openings and the entire route from the unloading point to the installation area before delivery. Once positioned, leave adequate clearance around the hinged doors and detachable panels for service access rather than placing the compressor directly against a wall.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver outlet is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 inch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so size the downstream distribution piping appropriately from that connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical supply should be confirmed before ordering. This is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208–230\/460V, 3-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e machine with a magnetic starter and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWye-delta reduced-voltage starting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy does not publish an amp draw or recommended breaker size for this configuration; both fields state \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e“Consult Certified Electrician.”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e We will not substitute an estimated electrical specification for the manufacturer's guidance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHave a licensed electrician size the service, feeder and disconnect from the actual machine nameplate and installation conditions before delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMulti-bay automotive and truck service shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need clean, dry compressed air throughout the working day without a separate plant room.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBody shops and finishing operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where moisture control is an important part of air quality.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication and light-production facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with steady, sustained compressed-air demand.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops that want an integrated package\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, rather than sourcing a compressor, receiver, dryer and connecting equipment separately.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFree air delivery\u003c\/th\u003e\n\u003ctd\u003e60.9 CFM (see the note on this figure above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSound level\u003c\/th\u003e\n\u003ctd\u003e71 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e208-230\/460V, 3-phase, Wye-Delta start, magnetic starter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmp draw \/ breaker\u003c\/th\u003e\n\u003ctd\u003eManufacturer states \"Consult Certified Electrician\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, oil-lubricated, gear drive, aftercooler fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e132 gallon horizontal, 1 inch outlet, no electronic drain valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir treatment\u003c\/th\u003e\n\u003ctd\u003eIntegrated refrigerant dryer plus air filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e74 in x 30.7 in x 72.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,296 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAccording to the manufacturer's feature list and specification table, the package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQGS-20S rotary screw compressor with gear-driven airend\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, Infologic2 Basic Controller with display panel, TEFC electric motor with IP55 wash-down protection, integrated refrigerated air dryer, 132-gallon horizontal receiver, aftercooler, air filter, pressure gauge, oil sight glass, magnetic starter, low-oil shutdown and spin-on fluid filter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAn electronic drain valve is not included.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Unless an automatic drain is added separately, plan on a manual tank-draining routine.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the current freight cost calculated at checkout based on your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe deliberately do not publish a fixed shipping figure because carrier rates vary by destination and can change over time. At this size and weight, unloading must be arranged before shipment. Plan for a suitable loading dock or forklift with sufficient capacity, or arrange pickup from the carrier's terminal if the delivery location cannot accommodate the freight.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eResidential delivery carries an additional residential fee.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the crate and equipment carefully when it arrives. Check for visible damage to the receiver, panels, gauges, guards and other exposed components. If you find damage, document it and have it recorded on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading before signing for the shipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe standard recorded warranty is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 year for consumer use and 1 year for commercial use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. An extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-Year Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies when the machine is commissioned through a Quincy-authorized startup, subject to the applicable warranty terms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause authorized startup is a condition of the extended coverage, schedule it as part of the installation rather than treating it as an optional service afterward.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a fault develops, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estop the compressor and contact us before opening or dismantling anything\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Unauthorized disassembly can complicate warranty evaluation and may affect coverage. Keep the unit intact until you have received instructions on how the issue should be handled.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954223636533,"sku":"4152022000","price":17559.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152022000__31873.1679921951.1280.1280.jpg?v=1788206572"},{"product_id":"quincy-air-compressor-15-hp-120-gallon-two-stage","title":"Quincy Air Compressor 15 HP 120 Gallon Two Stage","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy QP MAX 15 HP two-stage compressor\u003c\/strong\u003e includes a mounted air-cooled aftercooler that removes much of the moisture from compressed air \u003cstrong\u003ebefore it reaches the 120-gallon receiver\u003c\/strong\u003e. By lowering discharge temperature at the compressor, the system helps prevent bulk condensation from traveling into shop piping, where it can reach air tools or spray equipment. The heavy-duty cast-iron pump with aluminum heads runs at \u003cstrong\u003e1,750 RPM\u003c\/strong\u003e, uses a belt drive, and is rated for 175 PSI. Note: this 208V three-phase model measures 78\" × 28\" × 55\" and weighs 995 lbs, with a listed electrical draw of 48.3A.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003etwo-stage compression system\u003c\/strong\u003e uses a fin-and-tube intercooler between stages to cool the air before final compression. This reduces thermal stress on valves and rings while improving compression efficiency at higher pressures. The 120-gallon receiver provides stored air for sudden demand and reduces how frequently the pump needs to load. A \u003cstrong\u003espin-on oil filter, gerotor positive-displacement oil pump, oil sight glass, and low-oil shutoff\u003c\/strong\u003e support routine maintenance and help protect the pump from lubrication-related damage. Note that this configuration does not include an air dryer, so applications requiring low-dew-point air will need separate downstream air treatment.\u003c\/p\u003e\n\u003cp\u003eThis compressor is suited to \u003cstrong\u003eindependent automotive repair shops, tire and fleet operations, body and fabrication shops, and light manufacturing facilities\u003c\/strong\u003e with multiple air-consuming tools or equipment. Its 175 PSI rating and 120-gallon storage make it a practical choice where steady shop air matters more than occasional garage use. The unit requires \u003cstrong\u003e208V three-phase power\u003c\/strong\u003e, and electrical installation, disconnect, site preparation, and shop piping are not included. A licensed electrician should determine the appropriate breaker and conductor sizing for the actual installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Two Stages, and Why Cast Iron\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA single-stage pump compresses ambient air to its final pressure in one step. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e divides that work between two compression stages, with a fin-and-tube intercooler between them. Cooling the air between stages gives the second stage cooler, denser air to compress and reduces the heat load on components such as the valves and rings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThat staged compression is one reason two-stage designs are well suited to higher-pressure and demanding applications. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron cylinders and aluminum heads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e follow the same practical philosophy: cast iron provides durable cylinder surfaces and helps damp vibration, while aluminum heads transfer heat efficiently.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThere are five things to verify against your building before ordering:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFloor space.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The unit measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e78\" long × 28\" wide\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Allow additional working clearance around it so you can reach the belt guard, drain and oil fill without moving the compressor.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e At \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e55\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, it will fit beneath relatively low ceilings, but still requires adequate clearance around the cooler for unrestricted airflow.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFloor loading.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The compressor weighs approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e995 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and should be installed on a level, solid slab capable of supporting the equipment and suitable for mechanical handling.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Electrical supply is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V, three-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a listed current draw of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e48.3 A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this configuration. Quincy does not publish a specific breaker size and directs buyers to consult a certified electrician. The appropriate breaker and conductor sizing depends on the actual electrical run, installation conditions and applicable local code.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir connection.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The receiver has a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\" tank outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing the connection point for the shop's compressed-air distribution system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSite preparation, electrical feed, disconnect and connection to the shop's compressed-air piping are the customer's responsibility. The information on this page is not a substitute for an installation specification or for work performed by a properly licensed electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure, Storage and Why Tank Size Matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The receiver provides stored-air capacity between compressor load cycles and helps absorb short periods of higher demand without requiring the pump to respond instantly to every fluctuation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA larger receiver can also help reduce unnecessary cycling when demand varies, although the appropriate tank size ultimately depends on the compressor's output, operating pressure and application.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Oil Circuit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump is equipped with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003espin-on oil filter, Gerotor positive-displacement oil pump, oil sight glass and low-oil shutoff\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The system circulates and filters the lubricant, provides a visual way to check oil level and helps protect the pump from operation when the oil level becomes too low.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe spin-on filter also simplifies routine maintenance, allowing the consumable filter to be replaced without extensive disassembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIndependent repair shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e supplying several service bays from one compressor.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTire and fleet operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with frequent impact-tool use and sustained air demand.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBody and fabrication shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using sanders, plasma equipment or other pneumatic tools that require a steady supply.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLight manufacturing facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that already have compatible three-phase electrical service.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor arrives as an assembled package consisting of the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron two-stage pump, motor, 120-gallon horizontal receiver, magnetic starter, mounted air-cooled aftercooler, high-efficiency fin-and-tube intercooler, spin-on oil filter and oil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e208V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw (as listed by Quincy)\u003c\/th\u003e\n\u003ctd\u003e48.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum heads, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump speed\u003c\/th\u003e\n\u003ctd\u003e1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e78\" long × 28\" wide × 55\" tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e995 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eMounted air-cooled aftercooler; fin-and-tube intercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory warranty, extending to 3 years (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur product record identifies the receiver as built to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME pressure-vessel code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e among the unit's marks. These are not interchangeable certifications, and the relevant requirement is the one specified by your inspector, insurer or facility policy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn ASME pressure-vessel designation applies to the receiver and its construction; it should not be interpreted as a blanket certification of the complete electrical assembly. If your site requires a particular certification or listing for permanently installed equipment, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003everify it against the unit's data plate before purchase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rather than after installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eThree Things to Confirm Before You Order\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished information for this package differs on three points. We are flagging each discrepancy rather than choosing the version that appears most favorable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHow the pump is lubricated.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The manufacturer's package name and feature list describe the compressor as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efully pressure-lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while a specification field on this page records the oil system as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These describe different lubrication systems. If pressure lubrication is an important reason for choosing this model, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm it with us in writing before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and we will obtain the current factory specification from Quincy.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eThe automatic tank drain.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The product description, feature list and one specification record indicate that an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic automatic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is included, while another specification record lists none. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIf an automatic drain is a requirement, confirm the configuration with us before ordering.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDelivered air volume.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The published CFM figure for this machine is also associated with a unit of measure that we cannot independently verify. Rather than publish an ambiguous performance number, we have left it off this page. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAsk us and we will obtain Quincy's applicable factory airflow rating in writing before you order.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the current freight cost calculated at checkout for your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e995 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the machine requires suitable unloading equipment. Arrange a forklift or loading dock with adequate capacity, or choose terminal pickup if your delivery location cannot safely unload the shipment. Residential addresses are subject to an additional residential-delivery fee, which will be reflected in the freight quote at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the shipment before signing the delivery paperwork. Check the pallet, receiver, belt guard, gauges, feet and other exposed components for visible damage. If you find anything wrong, document it and have the damage recorded on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading while the driver is present\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with coverage extendable to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e subject to the conditions in Quincy's warranty handbook.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe warranty handbook is the governing document, and the extended coverage is conditional. Review the requirements before assuming the additional coverage applies to your installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf something goes wrong, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before disassembling the pump or other major components\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Opening the equipment before a warranty claim has been evaluated can complicate the manufacturer's assessment and may affect eligibility. Contact us first, document the problem and wait for instructions before beginning repairs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954237005877,"sku":"2020040918","price":11262.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3153D12HCB20M__13328.1679861756.1280.1280.webp?v=1788207014"},{"product_id":"quincy-air-compressor-15-hp-120-gallon-two-stage-208v-3-phase","title":"Quincy Air Compressor 15 HP 120 Gallon Two Stage 208V 3 Phase","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy QP Pro 10 HP two-stage compressor\u003c\/strong\u003e uses a pressure-lubrication system that sets it apart from conventional splash-lubricated reciprocating compressors. A \u003cstrong\u003egerotor positive-displacement oil pump\u003c\/strong\u003e delivers lubricant directly to the crankshaft, bearings, and connecting rods, while a spin-on oil filter removes contaminants from the circulating oil. Quincy rates this design for up to \u003cstrong\u003e15% longer service life\u003c\/strong\u003e than a comparable splash-lubricated pump. The horizontal 120-gallon receiver measures 78\" × 28\" × 55\" and weighs 995 lbs. Note: this model requires \u003cstrong\u003e208V three-phase power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003epressure-fed oil circuit\u003c\/strong\u003e provides more consistent lubrication than relying on the crankshaft to splash oil around the crankcase, particularly during cold starts and demanding operation. It also allows the use of a replaceable spin-on filter, making routine oil service straightforward. An oil sight glass provides quick level checks, while the cast-iron cylinders and fin-and-tube intercooler help manage operating temperatures. With a \u003cstrong\u003e175 PSI maximum working pressure\u003c\/strong\u003e and 1\" tank outlet, the compressor is designed for a properly piped shop air system rather than a basic hose-reel setup.\u003c\/p\u003e\n\u003cp\u003eThis compressor is a practical choice for \u003cstrong\u003ebusy independent repair shops, fabrication and welding operations, fleet facilities, and agricultural workshops\u003c\/strong\u003e with 208V three-phase service. It makes particular sense for shops that keep equipment on a regular maintenance schedule and want accessible wear and service components rather than a sealed system. The magnetic starter is included, but electrical feed, disconnect, shop piping, air treatment, and installation are not. Quincy does not specify a universal breaker or conductor size, so a certified electrician should size the electrical installation for your building and run length.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Pressure Lubrication Actually Buys\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe point is not that splash lubrication is inherently bad. The difference is how the lubricant reaches the loaded components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIn a splash-lubricated system, the crankshaft and connecting-rod assembly distribute oil through the crankcase. Oil delivery is therefore influenced by factors such as oil level, temperature and operating conditions. A pressure-lubricated system instead uses an oil pump to circulate lubricant through the system at controlled flow and pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor a compressor operating under sustained load, that distinction can matter because reliable lubrication is fundamental to bearing and component life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePressure circulation can also support \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efull-flow oil filtration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing lubricant to pass through a filter before reaching critical components. A spin-on oil filter is specified for this package, helping remove contaminants from the circulating lubricant.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThere is one important qualification: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eour available documentation is inconsistent about the lubrication method on this particular unit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The package description and feature list identify pressure lubrication, while another specification field records splash lubrication. We will not present one as confirmed until Quincy verifies it. If the lubrication system is a deciding factor in your purchase, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us for written confirmation of the factory configuration before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance You Can Actually Keep Up With\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIn practical terms, this compressor is designed around routine maintenance rather than complicated service procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e allows the oil level to be checked visually. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003espin-on oil filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed for straightforward replacement without major disassembly. The cast-iron cylinders and fin-and-tube intercooler help manage the heat generated during two-stage compression, while accessible service points make routine checks easier to perform with the compressor installed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNone of these features eliminates maintenance. The advantage is that the important maintenance tasks are visible and accessible, making them easier to incorporate into a working shop's regular service schedule.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis configuration uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e measuring approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e78 inches long × 28 inches wide × 55 inches high\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighing approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e995 lbs dry\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAllow more space than the published footprint alone suggests. The pump end needs enough clearance to access the belt guard and service points, the cooling system needs unrestricted airflow, and you should have sufficient room to position appropriate equipment beneath the receiver for draining.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompressed air exits through a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-inch outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the maximum working pressure is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical supply is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V, 3-phase configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Verify the voltage at your own electrical panel rather than assuming an existing three-phase circuit is compatible. Three-phase systems are available at different voltages, and the compressor must be matched to the available service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is included. Quincy does not publish a universal breaker or conductor size for this configuration and directs customers to consult a certified electrician. The appropriate electrical protection depends on the actual service, conductor run and applicable local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, verify the electrical supply, access route, floor area and installation clearances. Those checks are the buyer's responsibility and are far easier to resolve before delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBusy independent service shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with compatible 208V, three-phase power and sustained compressed-air demand.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication and welding shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where the compressor may operate for extended periods.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFleet and agricultural workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that place demanding, repeated loads on their compressed-air system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops with a disciplined maintenance program\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that track oil condition and service intervals rather than waiting for problems to appear.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e208V, 3-phase, magnetic starter fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage belt drive, cast-iron cylinders, full pressure lubrication by gerotor oil pump, spin-on oil filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValves and sealing\u003c\/th\u003e\n\u003ctd\u003eStainless steel reed valves with bumpers, graphite cylinder and head gaskets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eFan-type cast-iron flywheel, high-efficiency fin and tube intercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal, 1-inch outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall size\u003c\/th\u003e\n\u003ctd\u003e78 inches long, 28 inches wide, 55 inches high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e995 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClaimed benefit\u003c\/th\u003e\n\u003ctd\u003eUp to 15% longer life than a splash-lubricated pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eConfirm the Motor Rating Before You Order\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished information for the motor is inconsistent. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eproduct title, model designation and page heading identify this compressor as a 15 HP machine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while one section of the specification data records a smaller motor rating along with a corresponding free-air-delivery figure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe are carrying the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15 HP rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e because it is the figure supported by the title, model designation and page heading, but we are not treating the conflicting specification as irrelevant. At this size, motor rating affects the electrical requirements as well as the compressor's expected output.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eConfirm the motor rating and corresponding rated air delivery with us in writing before ordering.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e We will obtain both from Quincy so you can size the installation against the correct factory configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe ASME designation applies specifically to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressure vessel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — the receiver, its design, materials and construction. It should not be interpreted as a certification of the complete compressor package, pump, motor or compressed-air quality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLikewise, certification or listing marks do not replace local installation requirements, permits or any periodic pressure-vessel inspection that may apply in your jurisdiction. The electrical markings apply to the relevant electrical components and should be evaluated separately from the receiver certification.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore installation, confirm which certifications, inspections and permits your local authority, insurer or facility requires for a receiver of this size. Planning for those requirements before delivery is considerably easier than addressing them after installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the shipping cost calculated at checkout based on your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, arrange for safe unloading. This is not a hand-unload shipment; the destination needs an appropriately rated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eforklift or loading dock\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, or you can arrange terminal pickup and provide suitable equipment there.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlso make sure the delivery address is identified correctly. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eResidential deliveries carry an additional residential fee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so enter the address type accurately when obtaining your freight quote.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen the shipment arrives, inspect it \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore signing the delivery paperwork\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Check the receiver, guards, gauges, feet, fittings and exposed components for visible damage. If you find anything, photograph it and have the damage recorded on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading while the driver is present\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A clean signed delivery receipt can make a subsequent freight-damage claim considerably more difficult.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy provides a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e on this compressor. The specification information also identifies a Quincy maintenance kit associated with extended coverage, but the applicable warranty documentation governs the actual requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf an extended warranty is important to your purchase, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm the registration and maintenance requirements with us before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and complete any required registration promptly after delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954247884853,"sku":"2020040910","price":9579.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3153DS12HCA20-2__70652.1679862265.1280.1280.webp?v=1788207533"},{"product_id":"quincy-air-compressor-15-hp-120-gallon-two-stage-460v-3-phase","title":"Quincy Air Compressor 15 HP 120 Gallon Two Stage 460V 3 Phase","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eQuincy QT MAX 15 HP two-stage compressor\u003c\/strong\u003e is the 460V version for shops that already have industrial three-phase power and want moisture control built into the compressor package. Its factory-mounted \u003cstrong\u003eair-cooled aftercooler\u003c\/strong\u003e cools compressed air before it enters the 120-gallon receiver, allowing much of the condensate to separate at the machine instead of traveling through the shop's air lines. A high-efficiency finned intercooler provides additional cooling between the two compression stages. The splash-lubricated cast-iron pump runs at \u003cstrong\u003e1,750 RPM\u003c\/strong\u003e and is rated for more than 50,000 hours of pump life. Note: this model requires \u003cstrong\u003e460V three-phase power\u003c\/strong\u003e and weighs 923 lbs before oil.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eslow-speed two-stage pump\u003c\/strong\u003e is designed to reduce piston speed, heat, and wear compared with higher-speed reciprocating compressors. Cast-iron construction provides a rigid pump structure, while the aluminum head helps dissipate heat. Protection features include a \u003cstrong\u003elow-oil cut-off, magnetic starter with thermal overload protection, and tank drain\u003c\/strong\u003e to help address common causes of compressor damage. The 120-gallon receiver provides additional stored air for demanding applications, while the 1\" tank outlet gives you a solid starting point for properly sized shop piping. Published information differs regarding the tank drain configuration, so confirm the exact setup if automatic condensate removal is important to your installation.\u003c\/p\u003e\n\u003cp\u003eThis compressor is best suited to \u003cstrong\u003eproduction and fabrication shops, fleet and municipal maintenance facilities, tire and truck service operations, and finishing environments\u003c\/strong\u003e with 460V three-phase service. It is particularly useful where several air-consuming tools operate throughout the day and moisture control matters. The magnetic starter, aftercooler, intercooler, and other listed components are factory fitted, but electrical feed, disconnect, shop piping, dryer, filtration, regulator, and other installation items are not included. Have a certified electrician verify the electrical requirements before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy a Slow Pump Can Last Longer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe motor turns at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,750 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It is an easy number to skim past, but operating speed is an important consideration in the service life of a reciprocating compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA slower crankshaft generally means lower piston speed and fewer mechanical cycles for a given amount of operating time. That can reduce mechanical and thermal stress on components such as rings, cylinders and bearings compared with a higher-speed design.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy rates this \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash-lubricated cast-iron pump for more than 50,000 hours of pump life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, according to the published product information. The relatively low operating speed is one of the design characteristics supporting that long-life rating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron cylinder assembly with an aluminum head\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Cast iron provides a rigid, durable cylinder structure, while aluminum conducts heat efficiently away from the head area.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis model uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the crankshaft assembly distributing oil through the pump during operation. Unlike a pressure-lubricated system, there is no separate oil pump or pressure-fed lubrication circuit to maintain.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Parts That Help Protect It\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSeveral protective features are built into the compressor, each addressing a different operating risk.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil cut-off switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e shuts the machine down if the oil level falls to an unsafe point, helping prevent operation without adequate lubrication.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides motor protection through thermal overload devices. If the motor draws excessive current for long enough to create a damaging condition, the starter can disconnect it from the electrical supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is also identified in some of the published information for this model. Its purpose is to remove condensate from the receiver, helping limit moisture accumulation and corrosion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThere is an important qualification on that last point: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epublished descriptions of the tank drain differ\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Before relying on an automatic drain being factory-fitted, confirm the configuration with us.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e measuring approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e78 inches long × 28 inches wide × 55 inches high\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighing approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e923 lbs before oil\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan the installation around service access rather than treating the published dimensions as the complete space requirement. Leave room at the pump end for access to the belt guard, oil sight glass and filter, as well as adequate clearance around the cooling system for proper airflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tank has a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-inch outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing the connection point for the shop's compressed-air distribution piping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical supply is the major installation consideration. This configuration is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V, three-phase service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Verify the available voltage at your electrical panel before ordering; three-phase service is available at multiple voltages, and the compressor must match the supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter is included\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Quincy does not publish a universal breaker or conductor size for this configuration and directs customers to consult a certified electrician. The correct electrical protection depends on the actual service, conductor length, installation conditions and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduction and fabrication shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with compatible three-phase service and sustained pneumatic demand.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFleet and municipal maintenance facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where reliable compressed air is part of daily operations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTire and truck service shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where a large receiver helps provide stored-air capacity during periods of high demand.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePaint and finishing operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that benefit from an aftercooler as part of their compressed-air treatment system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Arrives\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is delivered assembled, with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage cast-iron pump and motor mounted on the horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, along with the magnetic starter, mounted air-cooled aftercooler, fin-and-tube intercooler, tank-drain equipment, low-oil cut-off and oil sight glass.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe documentation currently available does not list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecompressor oil, hose, downstream filtration, regulator, air dryer or isolation valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e as included accessories. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP, 460V, 3-phase, 1750 RPM, magnetic starter fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage belt drive, cast iron with aluminum head, splash lubricated, low oil cut-off, oil sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eBuilt-in air-cooled aftercooler plus high-efficiency finned intercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal, 1-inch outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall size\u003c\/th\u003e\n\u003ctd\u003e78 inches long, 28 inches wide, 55 inches high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e923 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory, extending to the 3-year No Bull cover on registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCheck the Tank Drain Before You Order\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished information about the tank drain is inconsistent. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emanufacturer's feature list and specification table both identify an automatic electronic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while a separate product-data field records the drain as not fitted.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eIf an automatic drain is important to your installation, ask us to confirm the configuration before your order ships.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e We will obtain written confirmation from Quincy rather than leave you to discover the discrepancy after delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specification sheet records \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME, UL and CSA marks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this compressor. It is important to understand what those designations actually cover.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME designation applies to the pressure vessel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — the receiver, its design, materials and construction. The electrical markings apply to the relevant motor and control components. None of these designations should be interpreted as certification of compressed-air quality or as approval of the complete installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDepending on your jurisdiction and facility requirements, you may also need permits or periodic pressure-vessel inspections. Certification marks do not replace those obligations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eCheck the requirements that apply to your site before installation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including any requirements imposed by your local authority, workplace inspector or insurer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to addresses within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Freight is quoted live at checkout based on your delivery address rather than built into the product price.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore ordering, make sure the destination can safely unload the machine. Depending on the site, that may require a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eforklift, loading dock or appropriately rated telehandler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. If the location cannot accommodate the delivery, terminal pickup is another option.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential deliveries are handled differently by freight carriers and carry an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eadditional residential-delivery fee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so make sure the destination type is entered accurately when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the shipment before signing the delivery paperwork. Check the pallet, receiver, guards, gauges, fittings and visible surfaces for signs of damage. If you find anything, photograph it and have the damage recorded on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading while the driver is present\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy provides a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e on this compressor, with the available documentation indicating that coverage can extend to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when the unit is registered with Quincy and maintained using the applicable Quincy maintenance kits, subject to the manufacturer's warranty terms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRegister the machine promptly after delivery if you intend to rely on the extended coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954262007861,"sku":"2020040896","price":9591.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2153D12HCA46M__49284.1679851285.1280.1280.jpg?v=1788208074"},{"product_id":"quincy-air-compressor-20-hp-132-gallon-rotary-screw-with-dryer-208-230-460v-3-phase","title":"Quincy Air Compressor 20 HP 132 Gallon Rotary Screw with Dryer 208-230\/460V 3 Phase","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy QGS rotary screw compressor\u003c\/strong\u003e is built for shops that may need to expand their compressed-air capacity over time. Its \u003cstrong\u003eInfologic2 Basic microprocessor controller\u003c\/strong\u003e can network with up to six compatible QGS compressors in the 20–30 HP range, allowing multiple units to operate as a coordinated system rather than independently loading whenever header pressure drops. That makes it a practical choice for a shop planning future growth. The compressor uses a belt drive, so belt inspection and eventual replacement are part of routine maintenance.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eintegrated refrigerated air dryer\u003c\/strong\u003e is a major part of the package, and the available product data consistently identifies it as included. The dryer removes condensed moisture before it can travel through the distribution system and reach air tools, pneumatic equipment, or finishing applications. The compressor is rated for \u003cstrong\u003e100% duty cycle\u003c\/strong\u003e and uses an oil-injected twin-screw airend with synthetic lubricant rated for up to 8,000 hours. A TEFC motor with IP55 protection, low-oil shutdown, an oil sight glass, and a spin-on fluid filter provide additional protection during continuous operation, while \u003cstrong\u003eWye-Delta reduced-voltage starting\u003c\/strong\u003e helps manage electrical inrush.\u003c\/p\u003e\n\u003cp\u003eThis package is suited to \u003cstrong\u003ebusy automotive service shops, fabrication facilities, light manufacturing operations, and growing businesses\u003c\/strong\u003e that need reliable compressed air throughout the workday. It is especially useful for facilities that may add another compressor later and want the option to coordinate multiple QGS units. The complete package measures \u003cstrong\u003e74\" × 30.7\" × 72.2\"\u003c\/strong\u003e and weighs 1,296 lbs, so verify door and overhead clearances before delivery. It requires \u003cstrong\u003e208–230\/460V three-phase power\u003c\/strong\u003e; Quincy does not publish a universal amp or breaker requirement, so a licensed electrician should size the electrical installation from the machine's nameplate and your site's requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBelt Drive on This Particular Unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump drive recorded for this model is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebelt driven\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. That is worth stating plainly because the drive type affects maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBelts are scheduled wear components. They should be inspected periodically for condition and tension and eventually replaced as part of normal maintenance. The upside is that belt drives are straightforward to service, relatively inexpensive to maintain and use widely available components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOther compressors in the same QGS family use \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egear-driven airends\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e instead. If avoiding belt maintenance is a priority, ask us about the comparable gear-driven models in the range. It is a genuine configuration difference worth considering before you order.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Running, and How the Machine Is Protected\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is rated for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, meaning it is designed for continuous operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe oil-injected twin-screw airend uses compressor fluid for lubrication and cooling, while the specified \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epremium synthetic lubricant is rated for up to 8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e under the applicable operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe motor is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTEFC design with IP55 protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing protection appropriate to the environments for which this equipment is designed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAdditional protective and service features include \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil shutdown, an oil sight glass and a spin-on fluid filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The low-oil protection is designed to stop the machine when the oil level reaches an unsafe condition, while the sight glass and filter support routine maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStarting uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWye-delta reduced-voltage starting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which reduces the initial electrical demand associated with starting the motor compared with full-voltage starting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit, and Can Your Building Feed It?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe complete package — compressor, dryer and horizontal receiver — measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e74\" long × 30.7\" wide × 72.2\" high\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,296 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIt is a relatively tall assembly, so check \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edoor heights, overhead obstructions and the complete delivery route\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, not just the available floor space. Once installed, leave sufficient clearance around the service panels and other access points.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver outlet is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing the connection point for the downstream compressed-air distribution system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical supply must be confirmed before ordering. This configuration is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208–230\/460V, three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and includes a magnetic starter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy does not publish an amp draw or recommended breaker size for this configuration; both fields direct the buyer to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e“Consult Certified Electrician.”\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e We will not replace that instruction with an estimate. Have a licensed electrician verify the available service and size the feeder, protection and disconnect according to the actual nameplate, installation conditions and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBusy multi-bay automotive shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e running pneumatic tools throughout the day.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication and light-manufacturing facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need continuous compressed air with integrated moisture control.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFinishing and pneumatic applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where reducing moisture downstream is important.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eGrowing operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that want substantial capacity now and the option to add another sequenced compressor later.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e20 HP, electric, TEFC with IP 55 wash-down protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e208-230\/460V, 3-phase, Wye-Delta start, magnetic starter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmp draw \/ breaker\u003c\/th\u003e\n\u003ctd\u003eManufacturer states \"Consult Certified Electrician\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, oil-lubricated, belt drive, aftercooler fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e132 gallon horizontal, 1 inch outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir treatment\u003c\/th\u003e\n\u003ctd\u003eIntegrated refrigerant dryer and air filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e74 in x 30.7 in x 72.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,296 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNetworking\u003c\/th\u003e\n\u003ctd\u003eInfologic2 Basic, up to six QGS units, 20 HP to 30 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAccording to the manufacturer's feature list, this package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQGS rotary screw compressor, Infologic2 Basic Controller with display panel, TEFC electric motor with IP55 protection, integrated refrigerated air dryer, 132-gallon horizontal receiver, air filter, pressure gauge, oil sight glass, aftercooler, low-oil shutdown, magnetic starter and spin-on fluid filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to addresses within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the current freight rate calculated at checkout for your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe do not publish a fixed shipping figure because freight rates vary by destination and carrier. At this size and weight, you need to arrange unloading before shipment. Plan for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eloading dock, an appropriately rated forklift or suitable terminal pickup\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e if the destination cannot safely unload the machine.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential deliveries carry an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eadditional residential-delivery fee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the shipment carefully when it arrives. Check the crate, receiver, panels, gauges, fittings and other visible components for damage, and have any damage documented on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading before signing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Once a shipment has been signed for without damage being noted, resolving a freight-damage claim can become considerably more difficult.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe recorded standard coverage is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 year for consumer use and 1 year for commercial use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. An extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-Year Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may apply when the unit is commissioned through a Quincy-authorized startup, subject to the manufacturer's warranty terms and conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause authorized startup is a condition of the extended coverage, arrange it as part of the installation rather than treating it as an optional service afterward.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a fault develops, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eshut the compressor down and contact us before dismantling or opening the equipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Opening the unit before the warranty claim has been evaluated can complicate the manufacturer's assessment and may affect coverage. Document the issue and let us coordinate the next step.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954280357941,"sku":"4152026537","price":22783.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152026537__94731.1679922812.1280.1280.jpg?v=1788208703"},{"product_id":"quincy-air-compressor-25-hp-132-gallon-rotary-screw-with-dryer","title":"Quincy Air Compressor 25 HP 132 Gallon Rotary Screw with Dryer","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy QGS 25 HP rotary screw compressor\u003c\/strong\u003e is a smart fit for shops that expect their air demand to grow but do not need to buy excess capacity today. Its \u003cstrong\u003eInfologic2 Basic controller can network up to six compatible QGS units in the 20–30 HP range\u003c\/strong\u003e, giving you a documented path to expand capacity without having separate compressors competing against each other. The package combines a 25 HP oil-injected twin-screw airend, 132-gallon horizontal receiver, integrated refrigerated air dryer, and aftercooler on one skid. Note: the unit measures \u003cstrong\u003e74\" × 30.7\" × 72.2\"\u003c\/strong\u003e, weighs 1,329 lbs, and requires 208–230\/460V three-phase power.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e100% duty-cycle rating\u003c\/strong\u003e means the rotary screw airend is designed for continuous operation rather than limited run periods. Premium synthetic lubrication, a spin-on fluid filter, oil sight glass, and low-oil shutdown on both the engine and pump support reliable operation during long shifts. A full sound enclosure and TEFC motor with IP55 wash-down protection make the package better suited to working environments where noise, dust, and moisture matter. The integrated refrigerated dryer provides \u003cstrong\u003edry compressed air\u003c\/strong\u003e, while the display provides pressure, temperature, and dewpoint information so operators can monitor the system rather than simply assume it is working.\u003c\/p\u003e\n\u003cp\u003eThis package is well suited to \u003cstrong\u003egrowing automotive shops, tire and body operations, blasting and production environments, and facilities with all-shift air demand\u003c\/strong\u003e. It is particularly valuable when you want to start with one compressor and add another later under coordinated control. The 132-gallon receiver, dryer, and aftercooler arrive as part of the packaged system, but electrical installation, wiring, plumbing, and commissioning are separate. An electronic drain valve is not included, so condensate management must be handled as part of the site's maintenance routine. A certified electrician should confirm the electrical installation requirements before delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit? Siting and Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eFootprint.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The complete package measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e74\" long × 30.7\" wide × 72.2\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,329 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The horizontal receiver gives it a relatively long, narrow footprint that can work well along a wall. Leave enough clearance around the hinged doors and detachable panels to open them fully and perform routine service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The motor is specified for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208–230\/460V, 3-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e power. Quincy does not publish an amp draw or recommended breaker size for this configuration and instead directs customers to consult a certified electrician. We will not substitute an estimate. Have your electrician size the feeder and overcurrent protection from the machine's actual nameplate and applicable local code, and resolve the electrical requirements before delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePlumbing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The receiver has a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\" outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing the connection point for the shop's compressed-air main.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic drain valve is listed as not included\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so plan for manual condensate draining unless an automatic drain is added separately. Assign that task to a specific maintenance routine rather than relying on memory.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuying One Compressor and Planning for Two\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAir demand often grows gradually, and adding a second compressor without a coordinated control strategy can make both machines operate less efficiently than intended.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy supports networking multiple QGS compressors in the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e20–30 HP range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e under a common control scheme, allowing the connected machines to coordinate operation rather than simply responding independently to the same demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThat provides a useful expansion path. If your current demand clearly requires more capacity, buying the appropriately sized compressor now makes sense. But if you are planning for demand that has not arrived yet, a compressor with a documented path for adding capacity can be a more flexible choice than purchasing a substantially larger machine based solely on projected growth.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e100% Duty Cycle, and What It Actually Means\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty-cycle rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e means the compressor is designed for continuous operation rather than requiring a scheduled rest period during normal operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThat is one of the key characteristics that makes an oil-injected rotary screw compressor appropriate for applications with sustained air demand. The airend uses oil for lubrication and cooling, while the package includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epremium synthetic lubricant, a spin-on fluid filter, oil sight glass and low-oil shutdown protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is also equipped with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efull sound enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a TEFC motor with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIP55 protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping make the package suitable for installation closer to occupied working areas than an unenclosed compressor might be.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStarting uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWye-delta reduced-voltage starting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which reduces starting current compared with full-voltage starting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edisplay controller\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides operating and alarm information, including pressure, temperature and dewpoint readings, allowing operators to monitor the compressor and integrated dryer rather than relying solely on external gauges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eGrowing shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that want a documented path to additional compressor capacity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSingle-package installations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where the compressor, 132-gallon receiver and dryer arrive together.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAll-shift compressed-air users\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e such as tire and body shops, blasting operations and light production.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWork areas where noise is a consideration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, thanks to the full sound enclosure and rotary screw design.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy's listed package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQGS rotary screw compressor, Infologic2 Basic Controller with display panel, TEFC electric motor with IP55 protection, integrated refrigerated air dryer and 132-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, together with the aftercooler, oil sight glass, pressure gauge, air filter and low-oil shutdown protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor power\u003c\/th\u003e\n\u003ctd\u003e25 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFree air delivery (CFM)\u003c\/th\u003e\n\u003ctd\u003e99.4 at 125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSound level (dBA)\u003c\/th\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor enclosure\u003c\/th\u003e\n\u003ctd\u003eTEFC, IP 55 wash-down, Wye-Delta start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, gear drive, oil lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntegrated refrigerated dryer\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver tank\u003c\/th\u003e\n\u003ctd\u003e132 Gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectronic drain valve\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eController networking\u003c\/th\u003e\n\u003ctd\u003eUp to six QGS units, 20 to 30 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage and phase\u003c\/th\u003e\n\u003ctd\u003e208-230\/460V, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw and breaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,329 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions, L x W x H\u003c\/th\u003e\n\u003ctd\u003e74\" x 30.7\" x 72.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specification sheet records an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME certification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this SKU, which is relevant given the package's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e132-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. ASME certification applies to the pressure vessel and is the type of documentation an inspector or insurer may require for the tank.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur current product data does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e identify an independent electrical or equipment-safety listing covering the packaged compressor as a whole, so we will not imply that one exists.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your jurisdiction, insurer or facility standards require a specific third-party listing for permanently installed equipment, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm that requirement before purchase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Ask us and we will obtain the applicable manufacturer documentation in advance rather than leave the question until inspection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the current freight cost calculated at checkout for the delivery address you provide.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,329 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the package requires suitable unloading equipment. Plan for a loading dock or appropriately rated forklift, or arrange collection from the carrier's terminal if the destination cannot safely unload the shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential deliveries carry an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eadditional residential-delivery fee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which will be reflected in the checkout freight quote when applicable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the crate and equipment before signing the delivery paperwork. Look for damage to the receiver, frame, panels, gauges, fittings and other exposed components. Photograph anything questionable and have the damage recorded on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading while the driver is present\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe standard published coverage is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 year for consumer use and 1 year for commercial use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. An extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-Year Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies when the machine is commissioned through a Quincy-authorized startup, subject to the manufacturer's applicable terms and conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause authorized startup is a condition of the extended coverage, arrange it \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore the first production run\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, not afterward.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf a fault develops, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before disassembling the airend, dryer circuit, motor or other major components\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Opening the equipment before a claim has been evaluated can make the cause of the failure difficult to establish and may affect warranty eligibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954289827893,"sku":"4152026541","price":23758.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152026541__28580.1679839335.1280.1280.webp?v=1788209191"},{"product_id":"quincy-air-compressor-30-hp-132-gallon-rotary-screw-3-phase","title":"Quincy Air Compressor 30 HP 132 Gallon Rotary Screw 3 Phase","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy QGS 30 HP rotary screw compressor\u003c\/strong\u003e is built for continuous-duty shops where maintenance intervals and operating costs matter as much as airflow. Part number \u003cstrong\u003e4152026533\u003c\/strong\u003e uses an oil-injected twin-screw airend with a \u003cstrong\u003e100% duty cycle\u003c\/strong\u003e and premium synthetic fluid rated for up to \u003cstrong\u003e8,000 hours\u003c\/strong\u003e, helping reduce the frequency of fluid changes while limiting oil carryover into the air system. The package includes a 132-gallon horizontal receiver, aftercooler, full sound enclosure, and Infologic2 control on one skid. Note: it measures \u003cstrong\u003e74\" × 30.7\" × 72.2\"\u003c\/strong\u003e, weighs 1,237 lbs, and requires 208–230\/460V three-phase power.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e8,000-hour fluid interval\u003c\/strong\u003e is especially relevant for a compressor that runs throughout the workday. Constant fluid monitoring, a spin-on fluid filter, oil sight glass, and low-oil shutdown on both the engine and pump help protect the airend and simplify routine maintenance. The oil-injected twin-screw design provides steady compressed-air delivery without the pulsation of a reciprocating pump, while the \u003cstrong\u003e100% duty rating\u003c\/strong\u003e allows the machine to operate continuously. A full sound enclosure helps reduce operating noise, and the TEFC motor provides IP55 wash-down protection. The Infologic2 Basic controller also supports programmable auto-restart, remote start\/stop, and networking with up to six compatible compressors.\u003c\/p\u003e\n\u003cp\u003eThis compressor is suited to \u003cstrong\u003ebusy automotive shops, fabrication facilities, production environments, and other operations with sustained air demand\u003c\/strong\u003e. Its compact, long-and-narrow package works well along a wall, provided there is enough clearance to open the service panels and maintain airflow. The 1\" receiver outlet provides the connection point for properly sized shop piping. An electronic drain valve is not included, and electrical feed, disconnect, plumbing, and commissioning are the customer's responsibility. Have a certified electrician verify the required electrical installation before delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit? Siting and Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eFootprint.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 74\" long, 30.7\" wide, and 72.2\" tall, with a shipping weight of 1,237 lbs. The horizontal receiver gives the package a long, narrow footprint that generally suits a wall run better than a floor island. Leave enough clearance to open the hinged doors and remove the detachable panels — the serviceability this machine is designed for depends on having access around the enclosure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The motor is listed as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208–230\/460V, 3-Phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Quincy does not publish an amp draw or recommended breaker size for this configuration and states that a qualified electrician should be consulted. We are not going to substitute an estimated number for a manufacturer specification. Your electrician should size the feeder and overcurrent protection from the nameplate on the delivered machine. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eArrange that evaluation before delivery, not after the compressor is sitting on the floor.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePlumbing and drainage.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The receiver outlet is 1\". An electronic drain valve is listed as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot included\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so condensate from the 132-gallon receiver must be managed manually unless a suitable drain system is added. Assign this task to someone and put it on a regular schedule; condensate management is part of owning a compressed-air system, not an occasional cleanup job.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eConfirming that the room, floor, electrical supply, ventilation, and drainage are suitable for a compressor designed for continuous operation is the customer's responsibility. It is also considerably easier to resolve those requirements before the crate arrives.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy an 8,000-Hour Fluid Interval Changes the Numbers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRotary screw compressors are purchased based on capacity but owned through their maintenance and operating costs. The fluid service interval sets the pace for a significant portion of that maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA synthetic fluid rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eup to 8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e can substantially extend the interval between fluid changes compared with shorter-interval systems, particularly in applications with long operating hours. The actual service schedule should still follow the manufacturer's maintenance requirements and operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLow oil carryover matters for more than fluid consumption. Oil that passes downstream can contaminate compressed-air piping, filters, tools, and finished work. Keeping separation and filtration performing properly therefore protects both the compressor and the equipment using its air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specified \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efluid filter, oil sight glass, and low-oil shutdown protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provide additional monitoring and protection, reducing reliance on operators simply remembering to check the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOil-Injected Twin Screw: What the Enclosure Adds\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn oil-injected twin-screw airend compresses air continuously between two meshing rotors rather than through the repeated piston strokes of a reciprocating compressor. In practical terms, that means smoother operation, lower vibration, and a more consistent compressed-air supply without the pulsation associated with piston compression.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty-cycle rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is particularly important for applications with sustained demand. Rather than requiring regular rest periods, the compressor is designed for continuous operation when properly installed and maintained.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe full sound enclosure complements that design by helping contain operating noise. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTEFC electric motor is rated IP55\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing protection against dust and water jets, which is useful in demanding shop environments. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWye-Delta reduced-voltage starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e also helps reduce electrical inrush during startup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eInfologic2 Basic microprocessor controller\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides programmable auto-restart and remote start\/stop functions and can network up to six compressors. The display provides operating indications including auto-run, general alarm, and power-on status, along with pressure and temperature information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops watching operating costs.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The 8,000-hour fluid rating can help extend maintenance intervals and simplify long-term planning.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSingle-delivery installations.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The compressor and 132-gallon receiver are packaged together on one skid.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDemanding shop environments.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The IP55 TEFC motor provides added protection against dust and water exposure.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAll-shift air demand.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The 100% duty-cycle design is suited to applications where compressed air is required continuously rather than intermittently.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy lists the package as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQGS rotary screw compressor with Infologic2 Basic controller and display panel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, TEFC electric motor with IP55 protection, and 132-gallon horizontal receiver.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listed equipment also includes an aftercooler, oil sight glass, pressure gauge, air filter, and low-oil shutdown protection for the engine and pump. An \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic drain valve is listed as not included\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor power\u003c\/th\u003e\n\u003ctd\u003e30 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFree air delivery (CFM)\u003c\/th\u003e\n\u003ctd\u003e113.8 at 125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSound level (dBA)\u003c\/th\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor enclosure\u003c\/th\u003e\n\u003ctd\u003eTEFC, IP 55 wash-down, Wye-Delta start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, gear drive, oil lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFluid service interval\u003c\/th\u003e\n\u003ctd\u003ePremium synthetic, rated 8,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver tank\u003c\/th\u003e\n\u003ctd\u003e132 Gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectronic drain valve\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage and phase\u003c\/th\u003e\n\u003ctd\u003e208-230\/460V, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw and breaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,237 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions, L x W x H\u003c\/th\u003e\n\u003ctd\u003e74\" x 30.7\" x 72.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specification sheet records an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME certification for this unit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which applies to the 132-gallon receiver — a pressure vessel that is subject to specific construction and testing requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhat our product data does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e document is an independent electrical or equipment safety listing covering the packaged compressor as a whole, and we are not going to imply that one exists.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your jurisdiction, insurer, or internal engineering standards require a specific third-party listing for permanently installed equipment, confirm that requirement \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore purchasing and before installation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Ask us and we can obtain the available manufacturer documentation in advance so you can verify the unit against your requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eFreight only to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping quoted live at checkout based on the delivery address you enter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,237 lbs on a long skid\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the shipment requires an appropriate unloading method. Plan for a loading dock or forklift at the delivery location, or arrange pickup from the carrier's terminal if that better suits your facility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential delivery may carry an additional residential fee, which will be shown at checkout when applicable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing for delivery.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e If you find visible damage, document it with photographs and have the damage noted on the bill of lading before signing. Once the shipment has been accepted without notation, resolving a freight-damage claim can become significantly more difficult.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished standard warranty coverage is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 year for consumer use and 1 year for commercial use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. An extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available, and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-year warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies when the compressor is commissioned through a Quincy-authorized start-up, subject to the applicable warranty terms and conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThat authorized start-up requirement matters. If the 5-year coverage is important to you, arrange the required commissioning \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore the compressor is put into service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, rather than assuming the coverage can be added later.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor any potential warranty issue, contact us before disassembling the compressor, airend, or motor. Unauthorized disassembly can complicate the warranty assessment and make it more difficult to establish the cause of a failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954299494453,"sku":"4152026533","price":22002.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152026533__42789.1679922640.1280.1280.webp?v=1788209580"},{"product_id":"quincy-air-compressor-30-hp-132-gallon-rotary-screw-with-dryer-3-phase","title":"Quincy Air Compressor 30 HP 132 Gallon Rotary Screw with Dryer 3 Phase","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy QGS rotary screw compressor, part number 4152026545\u003c\/strong\u003e, is designed for demanding shop environments where motor protection matters as much as continuous air production. Its \u003cstrong\u003eTEFC electric motor with IP55 wash-down protection\u003c\/strong\u003e helps shield against dust and low-pressure water from any direction, making this configuration particularly useful where compressors share air with sanding, welding, washing, milling, or other debris- and moisture-producing work. The package combines a 100% duty-cycle oil-injected twin-screw airend, 132-gallon horizontal receiver, integrated refrigerated air dryer, and aftercooler on a single skid. Note: the unit measures \u003cstrong\u003e74\" × 30.7\" × 72.2\"\u003c\/strong\u003e and weighs 1,365 lbs.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e100% duty-cycle screw airend\u003c\/strong\u003e is built for continuous operation rather than scheduled cool-down periods. Premium synthetic lubrication supports long service intervals and low oil carryover, while constant fluid monitoring, a spin-on filter, and low-oil shutdown help protect the compressor during extended use. The full sound enclosure reduces the noise associated with continuous operation, while the integrated refrigerated dryer removes moisture from the compressed-air system. The \u003cstrong\u003eInfologic2 Basic controller\u003c\/strong\u003e provides programmable auto-restart and remote start\/stop, and it can network up to six compatible compressors, giving growing facilities a way to add capacity under coordinated control. The display also provides pressure, temperature, dewpoint, and alarm information.\u003c\/p\u003e\n\u003cp\u003eThis configuration is particularly well suited to \u003cstrong\u003ebody shops, paint operations, fabrication facilities, woodshops, grain-handling environments, and other dusty or damp workplaces\u003c\/strong\u003e. It also makes sense for shops that want a complete compressor, receiver, and dryer package delivered as one system rather than assembling separate components. The horizontal design creates a long, relatively narrow footprint that can work well along a wall. Electrical service must be \u003cstrong\u003e208–230\/460V three-phase\u003c\/strong\u003e, and Quincy does not publish a universal amp or breaker requirement, so a certified electrician should size the installation from the machine's nameplate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit? Siting and Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eFootprint.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The package measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e74\" long, 30.7\" wide, and 72.2\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a weight of 1,365 lbs. The horizontal receiver gives the package a long, narrow footprint that generally works better along a wall than as a floor island. It still requires a level installation surface and sufficient clearance to open the hinged doors and remove the service panels — access that is essential for routine maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The motor is specified for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208–230\/460V, three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Quincy does not publish an amp draw or recommended breaker size for this configuration; the specification directs customers to consult a certified electrician. We are not going to substitute an estimate for a manufacturer specification. Your electrician should use the machine's nameplate to determine the appropriate feeder and overcurrent protection. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eArrange that evaluation before delivery is scheduled.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAir Outlet and Plumbing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The receiver outlet is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing the connection point for the shop's main air line. Plan the drop, isolation valve, and condensate-drain access before installation. The electronic drain valve is listed as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot included\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with this configuration, so condensate from the receiver will require manual draining or a separately installed drain solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eConfirming that the installation area, floor, electrical supply, ventilation, and drainage are suitable for a compressor designed for continuous operation is the customer's responsibility. It is considerably easier to resolve those requirements before the crate arrives.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat IP55 Wash-Down Protection Actually Means\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIP55-rated TEFC motor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed to provide protection against dust ingress and water projected by jets from any direction. That can be valuable in demanding shop environments where airborne debris or occasional water exposure is part of the working environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHowever, IP55 should not be treated as a guarantee against every type of contamination or exposure. Proper ventilation, installation, and routine maintenance still matter. If the compressor shares its environment with sanding, welding, washing, or machining operations, the motor's enclosed, protected design provides an additional layer of protection compared with a less-protected motor configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Duty and the Control That Goes With It\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe airend uses an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil-injected twin-screw design rated for 100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, meaning it is designed for continuous operation rather than requiring scheduled cool-down periods like a duty-limited reciprocating compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePremium synthetic lubrication is specified for extended service intervals, while oil separation and filtration help minimize oil carryover into the compressed-air system. The system also includes fluid monitoring and a spin-on fluid filter to support routine maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe rotary screw airend's continuous compression, combined with the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efull sound enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, also produces a smoother operating profile than a reciprocating piston compressor. The quieter operation comes from the compressor's design and enclosure rather than from a single isolated component.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eInfologic2 Basic microprocessor controller\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e manages start\/stop functions, programmable auto-restart, and remote start\/stop. It can also network up to six compressors, allowing additional capacity to be integrated into the control system later.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe display provides operating information including auto-run and alarm status, along with pressure and temperature readings. Where a refrigerated air dryer is included in the specific configuration, the available dryer information can also be used to monitor its operating status.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBody shops and paint operations.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The protected TEFC motor and integrated refrigerated air dryer make this configuration well suited to applications where air quality and reliable operation matter.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWoodshops and fabrication environments.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The enclosed, IP55-rated motor provides additional protection in areas where airborne dust or occasional water exposure is present.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops wanting one integrated package.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The compressor, receiver, and integrated dryer arrive together on a single skid.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOperations planning for future expansion.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The controller can network up to six compressors, providing a path for additional capacity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy lists this package as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQGS rotary screw compressor with Infologic2 Basic controller and display panel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, TEFC electric motor with IP55 protection, integrated refrigerated air dryer, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e132-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package also includes an aftercooler, oil sight glass, pressure gauge, air filter, and low-oil shutdown protection. An \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic drain valve is listed as not included\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor power\u003c\/th\u003e\n\u003ctd\u003e30 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFree air delivery (CFM)\u003c\/th\u003e\n\u003ctd\u003e113.8 at 125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSound level (dBA)\u003c\/th\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor enclosure\u003c\/th\u003e\n\u003ctd\u003eTEFC, IP 55 wash-down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, gear drive, oil lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntegrated refrigerated dryer\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver tank\u003c\/th\u003e\n\u003ctd\u003e132 Gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectronic drain valve\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage and phase\u003c\/th\u003e\n\u003ctd\u003e208-230\/460V, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw and breaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,365 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions, L x W x H\u003c\/th\u003e\n\u003ctd\u003e74\" x 30.7\" x 72.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specification sheet records an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME certification for this unit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which applies to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e132-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e included in this tank-mounted package. That certification covers the pressure vessel itself; it should not be interpreted as certification of the packaged compressor's electrical system, controls, or overall equipment assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBeyond the ASME certification, our product data does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot record an independent third-party electrical or equipment safety listing for the packaged machine as a whole\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. We are not going to imply that one exists.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your jurisdiction, insurer, or corporate engineering standards require a specific independent third-party listing for permanently installed equipment, confirm the requirement \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore purchasing and installation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rather than discovering it during an inspection. If needed, ask us for the available manufacturer documentation so you can verify the unit's compliance in advance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eFreight only within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping priced live at checkout based on the delivery address you provide.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,365 lbs on a long skid\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this shipment requires an appropriate unloading method. Plan for a loading dock, forklift, or other suitable equipment at the delivery location, or arrange pickup from the carrier's terminal if that is more practical.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential delivery may carry an additional residential fee, which will be shown at checkout when applicable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing for delivery.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Examine the crate and accessible components for visible damage, take photographs, and have any damage documented on the bill of lading before accepting the shipment. Once a shipment has been signed for without notation, resolving a freight-damage claim can become significantly more difficult.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished standard warranty coverage for this unit is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 year for consumer use and 1 year for commercial use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. An extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-year warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies when the machine is commissioned through a Quincy-authorized start-up, subject to the applicable warranty terms and conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe authorized start-up requirement is important if the 5-year coverage is your goal. Arrange the required commissioning \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore the compressor is placed into service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rather than assuming the extended coverage can be added afterward.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor any potential warranty issue, contact us before opening or disassembling the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eairend, dryer circuit, or motor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Unauthorized disassembly can complicate the warranty assessment and make it more difficult to establish the cause of a failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKeep the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecommissioning documentation and maintenance records\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e together, including fluid and filter service history. These records can be important when documenting proper maintenance and evaluating a warranty claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954808479797,"sku":"4152026545","price":25350.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Screenshot_2025-12-01_143229.webp?v=1788222795"},{"product_id":"quincy-air-compressor-40-hp-tankless-rotary-screw-3-phase","title":"Quincy Air Compressor 40 HP Tankless Rotary Screw 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etankless configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the defining feature of this 40 HP rotary screw compressor. Unlike tank-mounted packages, this model is supplied without a receiver, giving facilities the freedom to size and position their own storage tank around the demands of the entire air system. With the airend, motor and control cabinet supplied as a standalone package, it is a practical choice for installations that already have a receiver or are designing a centralized compressed-air system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egear-driven airend\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e eliminates belts as a scheduled maintenance item. Instead of checking tension and replacing matched belts, power transfers through hardened gears lubricated as part of the compressor's oil system. That also removes the efficiency loss associated with a slipping or incorrectly tensioned belt. Combined with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the oil-injected rotary screw design is intended for applications with steady air demand where the compressor can operate continuously rather than cycling through mandatory cool-down periods. The enclosure is rated at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e71 dBA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it suitable for installations where compressor noise is a consideration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor installation, the cabinet measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e44.5\" L × 30.7\" W × 49.2\" H\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e979 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230\/460V 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with Wye-Delta reduced-voltage starting. Quincy does not publish an amp draw or breaker size; a certified electrician should size the feeder, protection and starter arrangement from the machine nameplate. Allow clearance for the service panels and cooling airflow. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eThe receiver, electrical supply, installation and permits are not included.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished information also differs on the air dryer and ASME certification. The manufacturer's feature list mentions an integrated refrigerated dryer, while the specification table says no dryer and lists ASME certification despite the machine being tankless. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eConfirm these items in writing before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e if either affects your installation or inspection requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration is suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emanufacturing and fabrication facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, commercial service operations and other sites with existing receivers and air-treatment systems. It is particularly relevant where steady, continuous air demand calls for a dedicated rotary screw compressor rather than a large reciprocating unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGear drive: one less maintenance item to worry about\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump drive on this unit is specified as a gear drive. That matters because, on a belt-driven screw compressor, the belts are a wear item with their own maintenance schedule: they need to be inspected, tensioned and eventually replaced as a matched set. Each service requires shutting the machine down and opening the panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA gear drive eliminates that belt-maintenance routine. The motor and airend are connected through hardened gears, with the drive components lubricated by the same oil used by the compressor. In practical terms, the transmission is maintained as part of the compressor's normal oil-service routine rather than through a separate belt inspection and replacement schedule.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThere is another advantage that is easy to overlook. A slipping or incorrectly tensioned belt can waste power between the motor and airend without causing an obvious failure. The compressor still runs, but it may produce less air for the electricity it consumes. A direct gear connection eliminates that particular source of power loss, which is especially valuable on a compressor expected to operate for long periods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e100% duty cycle: designed for continuous operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor is rated for a 100% duty cycle. That is an important distinction from a reciprocating compressor, which is generally designed to run for a portion of the cycle and then shut down to cool. Running a reciprocating unit continuously can accelerate wear and shorten its service life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA rotary screw compressor is designed around continuous operation. The oil-injected screw element uses the compressor oil for lubrication, sealing and cooling, making the architecture well suited to applications with steady air demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your facility needs compressed air throughout the workday rather than in short, intermittent bursts, this is the type of compressor design that makes sense.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe enclosure is rated at 71 dBA. That is relatively quiet for an industrial compressor and should allow normal conversation nearby, although the actual experience will depend on the room, surrounding equipment and installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it fit, and what does installation involve?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe cabinet measures 44.5\" long, 30.7\" wide and 49.2\" tall, and the unit weighs 979 lbs. Because it is a tankless package, there is no receiver extending the footprint horizontally, which helps keep the overall installation relatively compact.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHowever, don't size the installation based on the cabinet dimensions alone. Leave enough room to open service doors and remove panels, and provide adequate clearance for cooling airflow. Before installation, verify that the access panels and hinged doors can actually be opened in the space you've selected.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical requirements deserve just as much attention. This is a 230\/460V, three-phase machine that uses a Wye-Delta reduced-voltage starter. Quincy does not publish an amp draw or recommended breaker size for this model; those specifications are listed as \"Consult Certified Electrician.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eRather than guessing at those numbers, have a licensed electrician verify the available service capacity, feeder sizing, protection and starter configuration against the compressor's nameplate before the unit arrives. A 40 HP three-phase compressor requires proper site preparation, and discovering an electrical limitation during installation can turn a straightforward equipment purchase into an expensive delay.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical service, site preparation and any required permits are the customer's responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat to verify about the dryer and certification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThere are two specifications worth confirming before purchase because the published information is not completely consistent.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFirst, Quincy's feature list for this compressor includes an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e\"Integrated Refrigerant Air Dryer.\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e However, the specification table on the same page lists the Air Dryer field as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e\"No.\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e If an integrated refrigerated dryer is an important reason you're considering this model, confirm the configuration in writing before committing to the purchase. We will verify it against the current Quincy factory order sheet.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specification table also lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e certification. ASME is a pressure-vessel code commonly associated with air receivers, yet this particular unit is listed as having no receiver. That raises the possibility that the certification field was carried over from another, tank-equipped configuration in the same product family.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf ASME marking is relevant to your inspection or compliance requirements, confirm the exact certification that applies to the unit you are ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIt is also important to distinguish ASME certification from electrical safety certification. ASME addresses pressure-vessel requirements; it is not an electrical safety listing and should not be treated as a substitute for one. If your insurer, local authority or facility standards require a North American third-party electrical listing for the control panel, verify that requirement against the machine's nameplate before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect for\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor is a strong fit for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emanufacturing and fabrication shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that already have a receiver and air-treatment system and need additional compressor capacity without adding another tanked package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIt also makes sense for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emulti-bay commercial service operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where compressed air is needed throughout the workday, as well as facilities with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esteady air demand\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that can take advantage of a rotary screw compressor's continuous-duty design.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhat it is not is a home-garage compressor or a plug-in machine. This is a 40 HP industrial package that requires appropriate electrical service, installation space, ventilation and supporting compressed-air infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e40 HP, electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e230\/460V, 3-phase, Wye-Delta reduced-voltage start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmp draw \/ breaker\u003c\/th\u003e\n\u003ctd\u003eQuincy states \"Consult Certified Electrician\" for both\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump type\u003c\/th\u003e\n\u003ctd\u003eRotary screw, oil-lubricated, gear drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e0 gallons — tank not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSound level\u003c\/th\u003e\n\u003ctd\u003e71 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e44.5\" x 30.7\" x 49.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e979 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package includes the QGS gear-driven rotary screw compressor, Infologic2 Basic Controller, 100% duty-cycle TEFC motor with IP55 wash-down protection, air filter, pressure gauge, oil sight glass, aftercooler, low-oil shutdown, spin-on fluid filter and magnetic starter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ereceiver tank and electronic drain valve are not included\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The refrigerant dryer remains the disputed item noted above.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis 979-lb compressor ships by freight to the lower 48 states, with shipping quoted at checkout based on your address. Because of its weight, delivery requires a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eloading dock or forklift\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, or pickup from the carrier's terminal. Residential deliveries may incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the crate and cabinet for damage before signing the delivery receipt. Any damage should be documented on the bill of lading before you accept the shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStandard coverage is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 year for consumer use and 1 year for commercial use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year extended factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-Year warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies when the compressor is commissioned by a Quincy-authorized technician.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eReview the warranty requirements before installation. If a problem occurs, contact us before opening or disassembling the unit, as unauthorized disassembly can affect warranty coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954816999477,"sku":"4152028076","price":20967.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152028076__50999.1679919301.1280.1280.webp?v=1788223172"},{"product_id":"quincy-air-compressor-40-hp-tankless-rotary-screw-with-dryer-230-460v-3-phase","title":"Quincy Air Compressor 40 HP Tankless Rotary Screw with Dryer 230\/460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4152028080\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a 40 HP gear-driven rotary screw compressor designed to deliver continuous air from a surprisingly compact cabinet. It measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e55.1\" long × 30.7\" wide × 49.2\" high\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs 1,087 lbs, making its 49.2\" height the standout feature for installations with limited headroom. The 100% duty cycle package includes an integrated refrigerated air dryer, while the tankless design lets you pair the compressor with a receiver sized and positioned for your specific air system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egear-driven airend\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e eliminates belt tensioning, belt replacement and power loss from belt slip. The TEFC motor includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIP 55 wash-down protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and Wye-Delta reduced-voltage starting, while the refrigerated dryer removes moisture before it reaches your distribution system. An aftercooler, spin-on fluid filter, oil sight glass, constant fluid monitoring and low-oil shutdown on both engine and pump support continuous operation. The Infologic2 Basic Controller adds programmable auto-restart, remote start\/stop and networking capability for up to six QGS compressors, with the display providing pressure, temperature and dewpoint information. The result is a compact package that combines compression and air treatment without requiring a separate dryer cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor installation, plan around the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e55.1\" × 30.7\" footprint and 49.2\" height\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with additional clearance for the hinged doors, detachable panels and cooling airflow. The compressor requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230\/460V 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e; Quincy does not publish an amp draw or breaker size, so a certified electrician should size the feeder and protection from the machine's nameplate. The compressor is supplied \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ewithout a receiver tank\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so existing or separately specified storage is required. No electronic drain valve is fitted.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration suits \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emanufacturing facilities, plant rooms and production shops with limited headroom\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, as well as operations that already have a receiver and want to add compressor capacity without duplicating storage. It is especially useful where continuous air demand, integrated drying and a compact installation footprint all matter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit? Siting and Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThe cabinet.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 55.1\" x 30.7\" x 49.2\" and 1,087 lbs. Measure your doorway and headroom against those numbers before ordering; a compressor that fits the room but not the route into it is a genuinely common and expensive mistake. Leave working space around the hinged doors and detachable panels. The machine is designed for service access from the outside, but only if you have not built shelving or equipment against it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Listed as 230\/460V AC, 3-Phase. Quincy publishes neither an amp draw nor a recommended breaker size, stating instead that a certified electrician should be consulted, and we will not put a number in that gap. Your electrician should size the feeder and overcurrent protection from the nameplate on the delivered machine. Have that conversation before delivery, not after it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eHeat.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A machine rated for a 100% duty cycle is designed to run continuously, and the electrical energy it consumes ultimately becomes heat that must be removed from the room. A small cabinet does not produce less heat than a larger one; it simply concentrates the equipment into a smaller footprint. Plan ventilation accordingly. Confirming that the installation site can accommodate the machine's power, heat and service requirements is the customer's responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy a Small Cabinet Is Worth Paying Attention To\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFloor space in a working shop is not free, and plant rooms are often whatever space was left over. A 40 HP package measuring just 55.1\" long and 49.2\" tall can change what is possible: it can sit beneath an existing mezzanine, tuck under low ductwork, or run against the wall of a service bay instead of consuming a corner of the shop floor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tankless configuration is part of that same argument. Because the receiver is separate, you can position it where it makes the most sense for your installation, including outside the building or in an elevated location where permitted by the installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe trade-off is straightforward: if you do not already have a suitable receiver, you will need to purchase one. A tankless compressor connected directly to the shop main is not a complete compressed-air storage system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGear Drive, and a Dryer Inside the Same Enclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe airend is gear driven rather than belt driven. There is no drive belt to tension or replace, and no belt slip between the motor and airend. On a machine designed for continuous operation, eliminating that wear item simplifies the maintenance schedule and removes one potential source of power transmission loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe motor is a TEFC design with IP 55 wash-down protection, and the package uses a Wye-Delta reduced-voltage start to reduce electrical inrush during startup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe refrigerated air dryer is integrated into the enclosure. Compressed air can carry moisture downstream, where it can contribute to corrosion in piping and equipment and create problems for applications sensitive to water contamination. Removing that moisture as part of the compressor package simplifies the installation and avoids dedicating separate floor space to a dryer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn aftercooler, oil sight glass, spin-on fluid filter, constant fluid monitoring and low-oil shutdown on both engine and pump complete the package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eControl is handled by the Infologic2 Basic Controller, with programmable auto-restart and remote start\/stop. It can network up to six QGS compressors, while the display provides pressure, temperature, dewpoint, motor-start and general status information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops short on floor space.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The 49.2\" height and 55.1\" length are the main advantages of this configuration.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePlant rooms with low headroom.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Useful beneath mezzanines, ductwork or other overhead restrictions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities that already own a receiver.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The tankless configuration avoids paying for another receiver when suitable storage is already available.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eContinuous production air.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The 100% duty-cycle rating is designed for sustained operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy lists this package as the gear-driven QGS rotary screw compressor, the Infologic2 Basic Controller with display panel, the 100% duty-cycle TEFC motor and the integrated refrigerated air dryer, together with an aftercooler, oil sight glass, pressure gauge, air filter and low-oil shutdown on both engine and pump.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor power\u003c\/th\u003e\n\u003ctd\u003e40 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFree air delivery (CFM)\u003c\/th\u003e\n\u003ctd\u003e154.9 at 125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSound level (dBA)\u003c\/th\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor enclosure\u003c\/th\u003e\n\u003ctd\u003eTEFC, IP 55 wash-down, Wye-Delta start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, gear drive, oil lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntegrated refrigerated dryer\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver tank\u003c\/th\u003e\n\u003ctd\u003eNone supplied, listed as 0 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage and phase\u003c\/th\u003e\n\u003ctd\u003e230\/460 Volt AC, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw and breaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,087 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions, L x W x H\u003c\/th\u003e\n\u003ctd\u003e55.1\" x 30.7\" x 49.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn ASME certification is recorded on the specification sheet for this unit. Be precise about what that means: ASME coding applies to pressure vessels, while this configuration ships without a receiver — the listed tank capacity is 0 gallons. If a coded vessel is what your inspector or insurer requires, that question belongs to the receiver you connect to this compressor. We will confirm exactly what the certification on this SKU covers before you commit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSeparately, our product data records no independent electrical or equipment safety listing for the packaged machine, and we are not going to imply that one exists. If your jurisdiction, insurer or corporate standard requires an independent third-party listing for installed equipment, establish that requirement before purchase rather than discovering it at inspection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by freight within the lower 48 states, with the shipping cost quoted live at checkout based on the delivery address you enter rather than estimated on this page. At 1,087 lbs, the unit requires a dock or forklift for unloading. If you have neither, terminal pickup from the carrier is the alternative.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential delivery carries a residential fee, shown at checkout where applicable. Inspect the crate before signing and record any damage on the bill of lading at the time of delivery. Once a clean bill is signed, a concealed-damage claim becomes much more difficult to pursue. Take photographs while the driver is still on site; those are often the evidence that makes a freight claim straightforward.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished standard coverage is 1 Year for consumer use and 1 Year for commercial use. An extended 3-Year factory warranty is available, and the True Blue 5-Year warranty applies when a Quincy-authorized start-up commissions the machine.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThat distinction matters: the longest warranty term depends on who performs the start-up, so the decision needs to be made before the compressor is first energized, not after it is already in service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhatever warranty term applies, do not open the airend, dryer circuit or motor before a claim has been raised and assessed. A disassembled component may be treated as an unverifiable failure and can complicate warranty coverage. Keep the commissioning paperwork together with your fluid and filter service records; both may be requested when a claim is evaluated.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954987163701,"sku":"4152028080","price":24170.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152028080__02831.1679919906.1280.1280.jpg?v=1788223912"},{"product_id":"quincy-air-compressor-4103d12hcb20m-qt-max-10-hp-120-gallon-two-stage-208v-3-phase","title":"Quincy Air Compressor 4103D12HCB20M QT Max 10 HP 120 Gallon Two Stage 208V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 15 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a two-stage reciprocating compressor built around a feature that directly affects the air coming out of your shop line: a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuilt-in, air-cooled aftercooler with a temperature-driven variable-speed fan\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The cooler reduces discharge temperature before air enters the receiver, helping remove moisture where it can be drained instead of allowing condensation to travel into your piping and tools. The package uses a splash-lubricated cast-iron pump with aluminum heads, belt drive and a 1,750 RPM motor, mounted on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Quincy rates the pump for more than 50,000 hours of service. Note: this configuration requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two-stage pump compresses air in two steps, with a finned intercooler between them to remove heat before the second stage. The result is cooler, denser air entering the final compression stage and less thermal stress on the pump. The machine is rated to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the aftercooler handles the heat and moisture leaving the pump before they reach the tank. An automatic electronic tank drain removes the condensate collected in the receiver, while the magnetic starter provides motor overload protection. A low-oil cut-off protects the pump if the oil level drops too far, and the oil sight glass makes routine level checks easy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis horizontal configuration is a practical choice for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecommercial service shops, fabrication and welding operations, and other facilities where moisture control matters\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e but floor height is limited. It measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e78\" long × 28\" wide × 55\" high\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs 850 lbs before oil, so plan for a level, solid slab and enough clearance for service access and cooling airflow. The 1\" tank outlet provides a suitable connection point for the shop air system. Electrical installation, breaker and conductor sizing should be handled by a certified electrician based on the site's supply and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage cast-iron pump, motor, 120-gallon horizontal receiver, magnetic starter, finned intercooler, built-in aftercooler with variable-speed fan, automatic electronic tank drain, low-oil cut-off and oil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. An air dryer is not included, so applications requiring dryer-grade air will need separate treatment equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWill it fit?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 78\" L × 28\" W × 55\" H\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 850 lbs dry\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 208V, 3-phase; not compatible with single-phase service or field voltage conversion\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eCircuit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Breaker and conductor sizing should be determined by a certified electrician based on the installation and local code.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\" tank outlet\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe horizontal design works well where wall length is available but ceiling height or floor space is limited. Install it on a level, load-bearing slab with appropriate service clearance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eSite preparation, electrical work and permits are the buyer's responsibility.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Confirm your 208V three-phase service and installation requirements before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBuilt-in protection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with motor overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil cutoff switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Together, these features help protect the motor and pump while making routine oil-level checks quick.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePerfect for\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomotive and service shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using impact tools, tire equipment and paint equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication and welding shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where moisture can affect plasma equipment and air tools.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLow-ceiling facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that can accommodate a horizontal 78\" footprint.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eCommercial sites with 208V three-phase power.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's in the box?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage cast-iron pump, industrial motor, magnetic starter, horizontal receiver, intercooler, air-cooled aftercooler with variable-speed fan, automatic electronic tank drain, low-oil cutoff and oil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis unit is recorded as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot including an air dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so plan for a separate dryer if your application requires dryer-grade air. The optional 3-year warranty extension is also not included and requires the EWK-4 Maintenance Kit to be purchased at the same time.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP industrial, 1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e208V, 3-phase, electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended breaker\u003c\/th\u003e\n\u003ctd\u003eTo be sized by a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarter\u003c\/th\u003e\n\u003ctd\u003eMagnetic, with thermal overload protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePump type\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump material\u003c\/th\u003e\n\u003ctd\u003eCast iron with aluminium heads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eOil lubricated, splash system, oil sight glass fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eFinned intercooler plus built-in air-cooled aftercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated pump life\u003c\/th\u003e\n\u003ctd\u003eMore than 50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTank size\u003c\/th\u003e\n\u003ctd\u003e120 gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTank orientation\u003c\/th\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003ctd\u003e78\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e55\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir dryer\u003c\/th\u003e\n\u003ctd\u003eNot supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, stated plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver is built to North American pressure-vessel standards, and the unit carries a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA mark\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Our supplier data also references a third-party North American electrical listing, but we have not confirmed that marking on this specific unit, so we will not claim it here.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your insurer or local inspector requires a specific electrical listing, ask us to verify what appears on the unit's data plate before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOne thing to confirm before you order\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe published information about the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is inconsistent. Quincy's feature list and detailed specifications show an automatic electronic drain, while a summary field lists it as absent.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf the drain is important to you, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us to confirm the shipping configuration before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. We will verify it with Quincy.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor ships by freight to the lower 48 states and is delivered to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecurb or dock line\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The carrier does not move the unit inside, so have a forklift or equipment mover ready. Terminal pickup is also available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential deliveries may incur an additional fee. Let us know if the delivery address is residential or lacks commercial receiving equipment so we can quote freight correctly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the crate before signing. Photograph any damage and record it on the bill of lading before the driver leaves.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for both consumer and commercial use. Purchasing the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-4 Maintenance Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with the machine extends coverage to Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year \"No Bull\" warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including on-site service and labor. Registration with Quincy is required for the extended warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you suspect a warranty issue, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estop the machine and contact us before disassembly\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Opening the pump can make it difficult to determine the cause of failure and may affect warranty coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45955107356725,"sku":"2020040882","price":7265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2103D12HCB20M__76078.1679924560.1280.1280.webp?v=1788224240"},{"product_id":"quincy-air-compressor-4103d12hcb23m-qt-max-10-hp-120-gallon-two-stage-230v-3-phase","title":"Quincy Air Compressor 4103D12HCB23M QT Max 10 HP 120 Gallon Two Stage 230V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 15 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a two-stage reciprocating compressor built around a feature that directly improves the air delivered to your shop: a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efactory-installed, air-cooled aftercooler with a temperature-driven variable-speed fan\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It cools compressed air before it reaches the receiver, causing much of the moisture to condense at the tank instead of later in your piping, tools or spray equipment. The package uses a splash-lubricated cast-iron pump with aluminum heads, belt drive and a 1,750 RPM motor on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rated to 175 PSI. Note: this model requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two-stage design compresses air in two steps, with a finned intercooler between the cylinders to reduce heat before the second stage. That cooler, denser air requires less work to compress and helps keep operating temperatures under control. The aftercooler then handles the discharge air before it enters the tank, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic electronic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e removes the condensate that collects there. A magnetic starter provides motor overload protection, and the low-oil cut-off stops the compressor if the oil level drops too far. The oil sight glass makes routine checks quick.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis configuration fits \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindependent automotive shops, fabrication and welding operations, and commercial facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need steady compressed air with better moisture control. Its horizontal design is also useful where ceiling height is limited: the unit measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e78\" long × 28\" wide × 55\" high\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs 850 lbs before oil. Allow additional space around the compressor for cooling airflow and service access, and provide a solid, level slab. The receiver has a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\" outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for connection to the shop air system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage cast-iron pump, motor, horizontal receiver, magnetic starter, finned intercooler, factory-installed aftercooler with variable-speed fan, automatic electronic tank drain, low-oil cut-off and oil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. An air dryer is not included, so applications requiring dryer-grade air will need separate air-treatment equipment. Electrical installation, circuit sizing and site preparation are the customer's responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 78\" L × 28\" W × 55\" H\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 850 lbs dry\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230V, 3-phase; not compatible with single-phase service\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBreaker:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e To be sized by a certified electrician according to the installation and local code\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eConnection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\" tank outlet\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e78\" length\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is especially important when planning the delivery route. Allow additional clearance for service and belt-guard access, and verify that the doorway, slab and final installation area can accommodate the unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eSite preparation is the buyer's responsibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including electrical service, slab capacity, ventilation, permits and inspections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for Easy Service\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash-lubricated cast-iron pump with aluminum heads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, plus an oil sight glass, low-oil cutoff and magnetic starter with motor overload protection. These features simplify routine checks and help protect the pump and motor from common operating problems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLow-ceiling shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and mezzanine installations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMulti-bay automotive service facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using air tools throughout the day.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBody and paint shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where moisture control is important.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eCommercial facilities with 230V three-phase power.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver, two-stage cast-iron pump, 10 HP motor, magnetic starter, intercooler, built-in air-cooled aftercooler with variable-speed fan, automatic electronic tank drain and low-oil cutoff\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHorsepower\u003c\/th\u003e\n\u003ctd\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor speed\u003c\/th\u003e\n\u003ctd\u003e1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e230V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarter\u003c\/th\u003e\n\u003ctd\u003eMagnetic, thermal overload protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStages\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump construction\u003c\/th\u003e\n\u003ctd\u003eCast iron cylinders, aluminium heads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOil system\u003c\/th\u003e\n\u003ctd\u003eSplash lubricated, sight glass, low oil cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum working pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeat management\u003c\/th\u003e\n\u003ctd\u003eFinned intercooler and built-in air-cooled aftercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall length\u003c\/th\u003e\n\u003ctd\u003e78\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall width\u003c\/th\u003e\n\u003ctd\u003e28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall height\u003c\/th\u003e\n\u003ctd\u003e55\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShipping weight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, stated plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver is manufactured to North American pressure-vessel standards, and the machine carries a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA mark\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Our records also reference a third-party North American electrical listing, but the information is not clear enough for us to claim it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf a specific electrical listing is required by your insurer or local code, contact us and we will confirm what appears on the unit's data plate before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eOne thing to confirm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur product data contains conflicting information about the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic electronic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The feature list and detailed specifications show one as included, while a separate summary field says it is not.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf the drain is important to your installation, ask us to verify the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eas-shipped configuration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e on a crate and skid. Plan for unloading with a suitable forklift or loading dock; carriers deliver to the truck, not inside the building. Terminal pickup is also available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential deliveries may incur an additional fee, so provide the correct delivery type when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the crate, skid and sheet metal before signing. Photograph any damage and record it on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before the driver leaves.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy provides a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for both consumer and commercial use. Purchasing the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-4 Maintenance Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with the compressor extends coverage to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year \"No Bull\" warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including on-site service and labor. Registration with Quincy is required for the extended coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you suspect a warranty issue, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before disassembly\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Opening the pump can make it difficult to determine the original cause of failure and may affect warranty coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45955195699253,"sku":"2020040883","price":7265.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2103D12HCB23M__06629.1679924702.1280.1280.png?v=1788224904"},{"product_id":"quincy-air-compressor-4103d12vcb20m-qt-max-10-hp-120-gallon-two-stage-208v-3-phase","title":"Quincy Air Compressor 4103D12VCB20M QT Max 10 HP 120 Gallon Two Stage 208V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 10 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a two-stage reciprocating compressor designed to deliver 35 CFM at 175 PSI while addressing one of the biggest problems with compressed air: moisture. Its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuilt-in air-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e removes heat from the discharge air before it enters the receiver, helping more moisture condense at the machine instead of inside your shop piping and tools. The package uses a splash-lubricated cast-iron pump on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon vertical ASME tank\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a factory-fitted magnetic starter and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe aftercooler works alongside a high-efficiency finned intercooler between the two compression stages. The intercooler reduces the temperature of the air before the second stage, while the aftercooler cools the finished compressed air before storage. That means \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless moisture reaches your downstream equipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and less water for your filters or dryer to handle. The 120-gallon receiver also provides stored air for short periods of higher demand, helping the compressor handle multiple tools without constantly cycling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor is a practical fit for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebusy automotive service shops, fabrication operations, and other commercial applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using impact tools, sanders, blast equipment or spray equipment. Its vertical configuration keeps the floor footprint relatively compact at roughly \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40\" × 30\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, although the approximately 75\" overall height and 1,000 lb weight require careful planning. Allow sufficient clearance around the tank and cooling components for airflow and routine maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOne detail to confirm before ordering is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic electronic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The available product information conflicts: some published details list an automatic drain while the specification field says it is not fitted. If automatic condensate removal is important to your installation, contact us and we will confirm the configuration for your exact unit. Electrical installation and circuit sizing should be handled by a certified electrician based on your site's requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo things to confirm before ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThe model code.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Two model numbers appear in the published information: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4103D12VCB20M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the title, description and specifications, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2103D12VCB20M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the page URL. Send us the code on your quote or purchase order and we will confirm the correct build with the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThe automatic tank drain.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The feature list and description say an automatic electronic drain is included, while the specification field says it is not. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIf the automatic drain is important to you, ask us to confirm it in writing before ordering.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy the aftercooler matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe aftercooler cools compressed air before it enters the receiver. As the air cools, moisture condenses in the tank instead of your air lines, reducing the load on downstream filters and dryers and delivering drier air to tools and spray equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efinned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e performs a different job between the compression stages. It cools the air before the second stage, reducing compression work and operating temperatures while helping extend valve life. Together, the two cooling systems improve efficiency and moisture control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSizing, siting and power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35 CFM and 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this compressor can support multiple air-consuming tools, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps handle demand peaks and reduce short cycling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe vertical unit measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40\" × 30\" × 75\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,000 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Check ceiling height, doorways and the entire delivery route before ordering. Install it on a level, solid surface with adequate clearance for cooling airflow and routine service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePower is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V, 3-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A factory-installed magnetic starter provides thermal overload protection. Quincy does not specify a breaker size; a certified electrician should size the circuit based on run length and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003e4103D12VCB20M (two codes in our data - see above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP, 208 Volt, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003e35 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum head, belt drive, splash lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eBuilt-in air-cooled aftercooler and finned interstage intercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eMagnetic starter with thermal overload, low oil cut-off switch, oil sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003e120 gallon, vertical, ASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFootprint\u003c\/th\u003e\n\u003ctd\u003e40 inches by 30 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e75 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,000 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAutomatic tank drain\u003c\/th\u003e\n\u003ctd\u003ePublished details differ - confirm with us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory, extending to 3-year pump cover on the manufacturer terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003ePerfect For\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePaint and body shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, where moisture can ruin finishes and create rework.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBlasting and cabinet work\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, where damp air can cause media problems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMulti-bay service shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e needing reliable 35 CFM output.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHumid climates\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, where effective aftercooling and moisture control are especially valuable.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's In The Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe factory-assembled package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage pump, motor, belt drive and guard, 120-gallon vertical receiver, aftercooler, intercooler, magnetic starter, low-oil cutoff and oil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe buyer supplies the electrical feed and disconnect, downstream piping, additional filtration or drying, isolation pads and initial oil service. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-4 Maintenance Kit is sold separately\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is required for the extended warranty option. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNo air dryer is included.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, stated honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy's specifications list an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME tank with UL and CSA marks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These certifications apply to the equipment itself, not to the installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYour electrician is responsible for ensuring the feeder, disconnect, protection and ventilation meet local requirements. If your insurer or local authority requires additional documentation, ask us before ordering so we can obtain it from the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout based on your ZIP code. Residential deliveries may incur an additional fee. Commercial delivery with a dock or forklift, or terminal pickup, may be more practical.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,000 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the unit requires suitable unloading equipment. Inspect the crate and compressor before signing and document any damage on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Quincy also offers extended coverage when the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-4 Maintenance Kit is purchased with the compressor and the unit is registered within the required period\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Current terms should be confirmed before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45960161755189,"sku":"2020040783","price":7802.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2103D12VCB20M__60984.1679852175.1280.1280.webp?v=1788279893"},{"product_id":"quincy-air-compressor-4103d12vcb23m-qt-max-10-hp-120-gallon-two-stage-230v-3-phase","title":"Quincy Air Compressor 4103D12VCB23M QT Max 10 HP 120 Gallon Two Stage 230V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 10 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is built for shops that need compressed air for as long as the work demands it. Unlike compressors designed to run only part of each hour, this model carries a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing it to operate continuously without a scheduled cool-down period. It combines a splash-lubricated cast-iron two-stage pump, 35 CFM at 175 PSI, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon vertical ASME receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and a 10 HP motor with a factory-fitted magnetic starter. Note: this configuration requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 100% rating is supported by a pump designed for sustained operation rather than short bursts. Its two-stage compression and deliberately modest operating speed help control heat while maintaining the output needed for demanding shop applications. The large receiver stores compressed air for periods of higher demand, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35 CFM output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides steady supply for multiple technicians using air tools or for equipment with sustained consumption. A magnetic starter with thermal overload protection adds another layer of protection when the motor is working hard.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor is suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindependent automotive repair shops, tire and fleet operations, fabrication facilities, and other commercial shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that regularly put their compressor under extended load. Its vertical receiver keeps the floor footprint relatively compact at approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40\" × 30\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, but the machine stands around 75\" tall and weighs roughly 1,000 lbs. Plan for a level, solid concrete pad, sufficient cooling clearance and a delivery route that can accommodate the height and weight.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTwo details should be confirmed before ordering. Available product information lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo different model codes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, 4103D12VCB23M and 2103D12VCB23M, so provide the code from your paperwork and we will verify the exact build. The information also conflicts on whether an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic electronic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is fitted: the feature list says yes, while the specification field says no. If the drain configuration matters to your installation, ask us to confirm it in writing before purchase. Electrical installation and circuit sizing should be handled by a certified electrician based on the site's service and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo discrepancies to confirm before ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eModel code.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Our product title, description heading and specifications list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4103D12VCB23M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the page URL and one paragraph list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2103D12VCB23M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. We will not guess. Send us the model code on your paperwork and we will confirm the exact build before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAutomatic tank drain.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The feature list and description say an automatic electronic drain is included, while the specification field says it is not. If the drain matters to your installation, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us to confirm the as-shipped configuration in writing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat 100% duty cycle means\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e means the compressor is designed to pump continuously without requiring scheduled cooling breaks. This design uses increased cooling capacity, a larger oil reservoir and a slower-running pump to manage heat during extended operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy rates the pump for approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, assuming proper maintenance such as regular oil changes, clean coolers and a maintained intake filter. A continuous-duty rating means you can work the machine hard—it does not eliminate maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSizing and installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35 CFM and 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this compressor can support multiple air tools or sustained applications such as blasting and spray equipment, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps handle demand peaks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe vertical unit measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40\" × 30\" × 75\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,000 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Check ceiling height, doorways and the entire delivery route before ordering. Install it on level, solid concrete with adequate clearance for cooling airflow and service access.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePower is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V, 3-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The factory-installed magnetic starter includes thermal overload protection. Quincy recommends having a certified electrician determine the breaker and conductor sizing based on the installation and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003e4103D12VCB23M (a second code exists in our data - see above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP, 230 Volt, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003e35 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron, aluminum head, belt drive, splash lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eAir-cooled aftercooler plus finned interstage intercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eMagnetic starter with thermal overload, low oil cut-off, sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003e120 gallon, vertical, ASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFootprint and height\u003c\/th\u003e\n\u003ctd\u003e40 inches by 30 inches, 75 inches tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,000 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAutomatic tank drain\u003c\/th\u003e\n\u003ctd\u003eSources disagree - confirm with us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory, extending to a 3-year pump term on the manufacturer conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003ePerfect For\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduction shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with continuous sanding, blasting or spray-booth use.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication and welding shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e running plasma equipment and air tools.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSecond-shift operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need continuous-duty performance.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities with 230V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ready for installation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's In The Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe factory-assembled package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage pump, motor, belt drive and guard, 120-gallon vertical receiver, aftercooler, intercooler, magnetic starter, low-oil cutoff and oil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe buyer supplies the electrical feed and disconnect, downstream piping, additional filtration or drying, vibration pads and first-service consumables. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-4 Maintenance Kit is sold separately\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is required for the extended warranty option. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNo air dryer is included.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, stated honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy lists an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME tank with UL and CSA marks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These certifications apply to the equipment as manufactured, not to the installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYour electrician is responsible for verifying the feeder, disconnect, overcurrent protection and ventilation requirements. If your insurer or local authority requires additional documentation, ask us before ordering so we can obtain it from the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout. Residential deliveries may incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,000 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, unloading requires a suitable forklift or loading dock, or you can arrange terminal pickup. Inspect the crate and compressor before signing and document any damage on the bill of lading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStandard coverage is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Purchasing the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-4 Maintenance Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with the compressor and registering it within the required period extends coverage to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2 years, with a 3-year pump warranty including on-site parts and labor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWarranty terms can change, so confirm the current requirements before purchase. If you have a warranty issue, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before disassembling the pump, motor or starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Keep all parts and document the issue with photographs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45960176730165,"sku":"2020040784","price":7802.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2103D12VCB23M__58789.1679852392.1280.1280.jpg?v=1788280452"},{"product_id":"quincy-air-compressor-4103d12vcb46m-qt-max-10-hp-120-gallon-two-stage-460v-3-phase","title":"Quincy Air Compressor 4103D12VCB46M QT Max 10 HP 120 Gallon Two Stage 460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 10 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is built for continuous-duty shops where protecting the compressor matters just as much as producing air. Its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo independent shutdown systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e address two different failure modes: a factory-fitted magnetic starter with thermal overload protection helps prevent motor damage from overload conditions, while a low-oil cut-off stops the pump if the oil level falls too far. Behind those safeguards is a splash-lubricated cast-iron two-stage pump delivering \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e into a 120-gallon vertical ASME receiver. Note: this configuration requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe protection systems are especially useful when the compressor runs for long periods without constant supervision. The magnetic starter monitors motor load and can shut the unit down during an overload condition, while the low-oil cut-off directly protects the pump from operating with insufficient lubrication. An \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a quick visual check before operation, so routine inspection can catch a problem before either shutdown has to intervene. The two-stage pump also uses a finned intercooler and air-cooled aftercooler to control compression temperatures during extended operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis model is suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomotive repair shops, fleet facilities, fabrication operations and other commercial applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that already have 460V three-phase service and need a compressor capable of sustained use. Its vertical receiver keeps the floor footprint around \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40\" × 30\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, but the approximately 75\" overall height and 1,000 lb weight require a suitable installation area. Provide a solid, level concrete pad, adequate airflow around the cooling components and enough clearance for service access.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTwo details should be confirmed before purchase. The available information lists different model codes, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4103D12VCB46M and 2103D12VCB46M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e; provide the code from your quote or purchase order so the exact build can be verified. Published information also conflicts on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic electronic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with some sources listing one and the specification field saying it is not fitted. If that feature is important to your installation, confirm the configuration in writing before ordering. Electrical feeder, disconnect and protection sizing should be determined by a certified electrician for your specific 460V service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo things to check before ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThe part number.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Our title, description and specifications list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4103D12VCB46M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the page URL and one sentence list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2103D12VCB46M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Send us the code on your quote or purchase order and we will confirm the correct build with the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThe automatic tank drain.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The feature list and description say an automatic electronic drain is included, while the specification field says it is not. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIf the automatic drain matters to your purchase, ask us to confirm it in writing before ordering.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo layers of protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe factory-installed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e includes an overload relay that protects the motor from excessive current caused by conditions such as a stalled pump or phase failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil cutoff\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e protects the pump from a different problem: insufficient lubrication. It shuts the compressor down if the oil level becomes dangerously low. An \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a quick visual check before operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy 460V matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis version is designed for facilities with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Higher voltage generally means lower current for the same power output, which can allow smaller conductors and feeders than lower-voltage configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy does not specify a universal breaker size because the correct selection depends on the installation and local code. Have a certified electrician confirm the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efeeder, disconnect and protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before ordering. This model is factory-wired for 460V and is not field-convertible to another voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned to run cool\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe QT MAX pump operates at a deliberately low speed to reduce heat and wear, supporting its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty-cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e design. A finned intercooler between compression stages and an air-cooled aftercooler before the tank provide additional temperature control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe vertical package occupies approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40\" × 30\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of floor space, stands about \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e75\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,000 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCheck ceiling height, doorways and the complete delivery route before ordering. Install it on level, solid concrete with sufficient clearance for cooling airflow and service access.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003e4103D12VCB46M (a second code appears in our data - see above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP, 460 Volt, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003e35 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum head, enclosed belt drive, splash lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor protection\u003c\/th\u003e\n\u003ctd\u003eMagnetic starter with thermal overload, factory wired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump protection\u003c\/th\u003e\n\u003ctd\u003eLow oil cut-off switch, oil sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eFinned interstage intercooler and air-cooled aftercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003e120 gallon, vertical, ASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e40 inches by 30 inches, 75 inches tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,000 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAutomatic tank drain\u003c\/th\u003e\n\u003ctd\u003ePublished details differ - confirm before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory, extending to a 3-year term on the manufacturer conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003ePerfect For\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities with 460V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that want to match their existing service.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUnattended or continuous operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, where built-in protection helps prevent major damage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduction shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e running blasting, finishing or assembly equipment continuously.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMaintenance teams\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that value automatic shutdown protection.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's In The Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe factory-assembled package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage pump, motor, enclosed belt drive and guard, 120-gallon vertical receiver, magnetic starter, low-oil cutoff, oil sight glass, intercooler and aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe buyer supplies the electrical feed, disconnect and protection, downstream piping, additional filtration or drying, isolation pads and first-service consumables. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNo air dryer is included.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, stated honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe manufacturer lists an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME tank with UL and CSA marks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These certifications apply to the equipment as manufactured, not to the installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYour electrician must verify the feeder, disconnect, overcurrent protection and ventilation requirements for your site. If your insurer or local authority requires additional documentation, ask us before ordering so we can obtain it from the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout. Residential deliveries may incur an additional fee. Commercial delivery with a dock or forklift, or terminal pickup, may be more practical.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,000 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, suitable unloading equipment is required. Inspect the crate and compressor before signing and document any damage on the bill of lading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe unit includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with eligibility for an extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year term\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when the manufacturer's registration and maintenance requirements are met. Confirm the current conditions with us before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45960191836213,"sku":"2020040785","price":7802.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2103D12VCB46M__61092.1679852719.1280.1280.webp?v=1788280793"},{"product_id":"quincy-air-compressor-4103ds12hcb23-qt-pro-10-hp-120-gallon-two-stage-230v-3-phase","title":"Quincy Air Compressor 4103DS12HCB23 QT Pro 10 HP 120 Gallon Two Stage 230V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 4103DS12HCB23\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e puts a 10 HP, two-stage compressor on a horizontal 120-gallon receiver, giving you \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI performance in a 55\" tall package\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Its 78\" × 28\" footprint makes it a practical alternative to a taller vertical tank when overhead clearance is limited. The pump is cast iron, splash lubricated and belt driven by a 230V, 3-phase motor running at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,750 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with Quincy rating the pump for 50,000 hours or more. Note: this model requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe low pump speed is a key part of the design. Running at 1,750 RPM reduces piston speed and helps control operating temperatures, which puts less stress on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003erings, valves and bearings\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e during extended use. The two-stage pump also passes air through a high-efficiency finned intercooler between stages before reaching its final pressure. Cooling the air between compression stages reduces the work required by the second stage and helps control the heat and moisture entering the receiver.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor is a strong fit for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomotive and truck service shops, fabrication facilities, welding operations and light manufacturing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need steady compressed air throughout the workday. The horizontal receiver is particularly useful in converted garages, low-ceiling bays, basements and other locations where a 120-gallon vertical tank will not fit. At approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, it requires a suitable load-bearing floor and adequate clearance around the pump, belt guard and tank connections. The 1\" tank outlet also gives you a solid starting point for properly sized shop piping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA factory-fitted \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps protect the motor during overload conditions, while the ASME-certified receiver includes a pressure relief valve. Shop piping, electrical disconnects, filtration and dryers are separate installation requirements. Quincy does not specify a fixed breaker size for this model, so have a certified electrician size the circuit according to your service, conductor run and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy 1,750 RPM Matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHorsepower isn't the only factor that determines compressor life. This belt-driven pump runs at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,750 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, reducing piston speed, bearing stress and operating temperatures compared with faster-running consumer compressors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubrication and an extra-capacity oil reserve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping control heat and extend oil life. Combined with cast-iron cylinders and an aluminum head, Quincy rates the design for approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of service life.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Stages and the Intercooler\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two-stage pump compresses air in two steps, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between them. Cooling the air before the second stage reduces the work required to reach \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, lowers operating temperatures and helps remove moisture before it reaches the tank and air lines.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarter, Connecting Rods and Tank Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA factory-installed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e protects the motor from overload and stalled conditions. The two-piece connecting-rod design simplifies maintenance and rebuilding.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME-certified receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e includes a pressure relief valve and 1\" discharge connection. Properly sized shop piping is essential to avoid restricting the compressor's output.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 78\" L × 28\" W × 55\" H\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 850 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230V, 3-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMaximum pressure:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 175 PSI\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTank:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 120 gallons\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomotive and truck shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e running multiple air tools and equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication and welding shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using plasma cutters and other continuous-demand tools.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLow-ceiling facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where a tall vertical compressor won't fit.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLight manufacturing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requiring steady compressed air throughout a shift.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage cast-iron pump, 1,750 RPM motor, belt drive and guard, finned intercooler, magnetic starter and 120-gallon ASME-certified receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with pressure relief valve and discharge connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e4103DS12HCB23 (QT Pro)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP, electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump speed\u003c\/th\u003e\n\u003ctd\u003e1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump type\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive, cast iron with aluminium head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eSplash lubricated, oil sight glass fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMagnetic starter\u003c\/th\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended breaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003ctd\u003e120-gallon, horizontal, ASME certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003ctd\u003e78\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e55\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAftercooler \/ air dryer\u003c\/th\u003e\n\u003ctd\u003eNot fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectronic drain valve\u003c\/th\u003e\n\u003ctd\u003eNot fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver is an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME-certified pressure vessel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the manufacturer also lists a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA mark\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These certifications cover different aspects of the equipment: ASME applies to the pressure vessel, while electrical markings apply to the motor and controls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAlways verify the markings on the unit's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edata plate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when it arrives. If your inspector, insurer or facility requires a specific listing, confirm it before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850-lb compressor ships by freight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to the lower 48 states. Unloading requires a suitable forklift, loading dock or arranged terminal pickup. Residential deliveries may incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with eligibility for Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year \"No Bull\" warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when the manufacturer's requirements are met. These may include purchasing the required maintenance kit with the compressor and registering the unit with Quincy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45960213233717,"sku":"2020040875","price":6018.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/P2103DS12HCB23__21921.1679848526.1280.1280.webp?v=1788281518"},{"product_id":"quincy-air-compressor-4103ds12hcb46-qt-pro-10-hp-120-gallon-two-stage-460v-3-phase","title":"Quincy Air Compressor 4103DS12HCB46 QT Pro 10 HP 120 Gallon Two Stage 460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 10 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in this configuration is built for facilities with 460V three-phase service, combining a lower-current electrical setup with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal ASME-certified receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The 1,750 RPM belt-driven, splash-lubricated cast-iron two-stage pump delivers up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with Quincy rating the pump for 50,000 hours or more of service. Its horizontal design measures 78\" long, 28\" wide and 55\" tall, making it a practical choice where ceiling height is limited. Note: this version requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and must be installed on a properly sized circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 460V motor draws less current than an equivalent lower-voltage configuration, which can affect feeder and disconnect requirements, particularly when the compressor is located far from the electrical panel. The pump operates at a relatively low \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,750 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping control piston speed, bearing loads, oil temperature and operating noise during extended use. Two-stage compression sends air through a high-efficiency finned intercooler between stages, reducing the heat and moisture carried into the receiver while allowing the second stage to efficiently reach 175 PSI.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor is suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindustrial facilities, fleet and heavy-equipment shops, fabrication operations and other commercial applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that already have 460V three-phase distribution. The horizontal tank works particularly well under mezzanines, low beams and in older buildings where a vertical 120-gallon receiver would create a clearance problem. At approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, it requires a level, load-bearing floor with service clearance around the pump, belt drive and tank connections. The 1\" tank outlet should also be considered when sizing the shop's distribution piping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA factory-fitted \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps protect the motor during overload conditions. Electrical service, circuit sizing, disconnects, site preparation, piping and downstream filtration are installation requirements outside the compressor package. Have a certified electrician verify the 460V supply and size the circuit according to the machine nameplate, conductor run and applicable code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the Voltage First\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Check your electrical service before ordering—three-phase motors are not something you can simply rewire between voltage classes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy does not publish a fixed breaker size and recommends a certified electrician determine the correct overcurrent protection based on conductor size, run length and local code. This is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehard-wired industrial equipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, not a plug-in appliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Stage Compression with Intercooling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump compresses air in two stages, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between them. Cooling the air before the second stage reduces the work required to reach \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, lowers operating temperatures and helps remove moisture before it reaches the tank and air lines.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for Continuous Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump runs at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,750 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, reducing piston speed, bearing load, oil temperature and noise. Splash lubrication draws from an extra-capacity oil reserve, while the two-piece connecting rods simplify maintenance and rebuilding.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA factory-installed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e protects the motor from overload conditions and provides controlled starting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e keeps the package compact at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e78\" L × 28\" W × 55\" H\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Its low profile works well under mezzanines, low ceilings and beams where a vertical receiver may not fit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAllow clearance for the drain, discharge and belt access, and install the unit on a flat, level, load-bearing floor. The tank outlet is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e; properly sized shop piping is important to avoid restricting airflow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities with 460V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e already available.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTruck, fleet and heavy-equipment shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e running air tools for long shifts.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication and finishing operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requiring steady air pressure.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInstallations far from the electrical panel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, where lower current can reduce feeder requirements.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage cast-iron pump, 1,750 RPM industrial motor, belt drive and guard, finned intercooler, magnetic starter and 120-gallon ASME-certified horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with pressure relief valve and discharge connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e4103DS12HCB46 (QT Pro)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP, electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump speed\u003c\/th\u003e\n\u003ctd\u003e1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive, cast iron with aluminium head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eSplash lubricated, oil sight glass fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e460V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMagnetic starter\u003c\/th\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended breaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003ctd\u003e120-gallon, horizontal, ASME certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003ctd\u003e78\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e55\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAftercooler \/ air dryer\u003c\/th\u003e\n\u003ctd\u003eNot fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectronic drain valve\u003c\/th\u003e\n\u003ctd\u003eNot fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME certified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the manufacturer also lists a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA marking\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These cover different areas: ASME applies to the pressure vessel, while electrical safety markings apply to the motor and controls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen the unit arrives, verify the markings on its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edata plate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. If your insurer, local code or facility requirements call for a specific listing, confirm it before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850-lb compressor ships by freight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to the lower 48 states. Unloading requires a forklift, loading dock or arranged terminal pickup. Residential deliveries may incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the crate and compressor before signing. Document any damage on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e while the carrier is still present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe unit includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Quincy offers a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year \"No Bull\" warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when the manufacturer's requirements are met, including purchasing the matching maintenance kit with the compressor and registering the unit with Quincy. The extended coverage includes on-site service and labor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45960238530613,"sku":"2020040876","price":6018.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2V41C60VC__59505.1679754391.1280.1280.jpg?v=1788282195"},{"product_id":"quincy-air-compressor-4103ds12vcb46-qt-pro-10-hp-120-gallon","title":"Quincy Air Compressor 4103DS12VCB46 QT Pro 10 HP 120 Gallon","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 10 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is built for industrial installations where the receiver certification and electrical configuration need to be clear from the start. It combines a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon ASME-certified vertical receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a two-stage cast-iron pump, 1,750 RPM belt drive and a 460V, 3-phase motor. The pump is rated for more than \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000 hours of service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and up to 175 PSI, while the ASME receiver includes the required pressure relief valve and discharge arrangement. Note: this configuration requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two-stage pump uses a high-efficiency finned intercooler between the cylinders to control interstage temperatures before the air reaches final pressure. Its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron construction, aluminum heads and two-piece connecting rods\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e are designed for long-term service, while splash lubrication keeps the pump straightforward to maintain. This configuration does not include an aftercooler, electronic tank drain or low-oil shut-off, so receiver drainage and oil-level checks remain manual maintenance tasks. If your application requires drier air, plan for downstream air treatment separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis model is a practical fit for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emanufacturing plants, industrial facilities, fleet operations and commercial shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that already have 460V three-phase distribution and need a documented pressure-vessel configuration. The vertical package occupies approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40\" × 30\" of floor space\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, stands about 75\" tall and weighs roughly 1,000 lbs dry. Plan for a solid, level slab capable of supporting and anchoring the machine, adequate headroom for service work, sufficient ventilation and a delivery route that can accommodate the equipment. The 1\" outlet should also be considered when designing the shop's air header.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe factory-fitted \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps protect the motor during overload conditions. Quincy does not publish a fixed breaker size for this model; have a certified electrician size the feeder, disconnect and overcurrent protection for your specific 460V service and installation. Permitting, electrical work, site preparation, downstream piping and air treatment are separate installation responsibilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Receiver and Its Certification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon receiver is an ASME-certified pressure vessel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with the required safety fittings. This documentation is useful for plant safety audits, insurance inspections and sites that maintain a pressure-vessel register.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning a 460V Machine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis model requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is factory-wired for that voltage. The motor and magnetic starter are not designed for field conversion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eHave a certified electrician verify the available voltage before ordering. Quincy does not publish a fixed breaker size because conductor and overcurrent requirements depend on the installation, run length and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstalling a Tall Vertical Package\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40\" × 30\" × 75\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,000 lbs dry\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBefore delivery, confirm:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eA level, load-bearing slab suitable for anchoring.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnough headroom for the machine and future pump service.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDoorway and delivery-route clearance.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdequate ventilation for the 10 HP motor and pump.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eProperly sized piping from the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\" tank outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhere the QT Pro Fits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis QT Pro configuration is a simpler package with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eno aftercooler, electronic drain valve or low-oil cutoff\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The finned intercooler provides cooling between compression stages, while receiver draining and oil-level checks are manual.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eManufacturing facilities with 460V three-phase power.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eSites requiring a documented, code-certified receiver.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eInstallations with long electrical runs.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePlant rooms with limited floor space\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e but sufficient ceiling height.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon ASME-certified receiver, pressure relief valve, two-stage cast-iron pump with aluminum heads, 10 HP motor, magnetic starter with thermal overload protection, finned intercooler and oil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor speed\u003c\/th\u003e\n\u003ctd\u003e1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e460V, 3-phase, electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarter\u003c\/th\u003e\n\u003ctd\u003eMagnetic, thermal overload protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCircuit protection\u003c\/th\u003e\n\u003ctd\u003eSized on site by a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCompression\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eCast iron cylinders, aluminium heads, two-piece rods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eSplash, oil lubricated, sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInterstage cooling\u003c\/th\u003e\n\u003ctd\u003eHigh-efficiency finned intercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated pump life\u003c\/th\u003e\n\u003ctd\u003eMore than 50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, vertical, ASME certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety fittings\u003c\/th\u003e\n\u003ctd\u003ePressure relief valve, discharge, receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePlan size\u003c\/th\u003e\n\u003ctd\u003e40\" by 30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDry weight\u003c\/th\u003e\n\u003ctd\u003e1,000 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, stated plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pressure vessel is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME certified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the machine also carries a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA mark\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Our supplier records mention an additional North American third-party electrical listing, but we have not confirmed it on this specific unit, so we will not claim it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your insurer or inspector requires a specific electrical listing, contact us and we will verify the markings on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edata plate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e on a skid. Have a forklift or loading dock ready for unloading, or arrange terminal pickup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential deliveries may incur an additional fee. Let us know the delivery type when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the shipment before signing. Photograph any damage and record it on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for consumer and commercial use. Purchasing the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-4 Maintenance Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with the compressor and registering the unit with Quincy extends coverage to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year \"No Bull\" warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including on-site service and labor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you suspect a warranty issue, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before disassembly\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Keep the unit intact and document the problem with photographs to protect your claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45960256520245,"sku":"2020040777","price":6469.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/P2103DS12VCB46__50481.1679924072.1280.1280.png?v=1788282911"},{"product_id":"quincy-air-compressor-4152021976-qgs-15-hp-120-gallon-rotary-screw","title":"Quincy Air Compressor 4152021976 QGS 15 HP 120 Gallon Rotary Screw","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQGS rotary screw compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers 54.9 CFM at 125 PSI with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving busy shops continuous air without the rest periods associated with reciprocating compressors. This configuration is intentionally supplied without a refrigerated dryer or aftercooler, making it a practical choice for facilities that already have downstream air treatment or need to specify filtration and dewpoint equipment for a particular application. The package measures 76\" long, 25\" wide and 58\" tall, weighs 815 lbs and requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208-230\/460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Note: air treatment is not included and must be provided separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the key performance advantage for sustained demand. The screw element can continue producing air while multiple technicians work, rather than relying on a tank to carry the shop through repeated pump rest periods. Auto-Dual controls add another practical benefit by allowing programmed shutdown periods, so the compressor does not continue running unnecessarily when the shop is closed. Premium synthetic lubrication is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while low-oil shutdown and an oil sight glass help protect and monitor the compressor during routine operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA long-life V-belt drive keeps the mechanical system straightforward to service, although belt tension and condition still need periodic inspection. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTEFC motor and quiet enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e are suited to commercial shop environments, while the horizontal 120-gallon receiver keeps the package relatively low and narrow at just 25\" wide. The 1\/2\" receiver outlet should be considered when planning the air header, and adequate service clearance should be left around the compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration is a good fit for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emulti-bay automotive shops, fabrication and machining facilities, and operations that already own a dryer and filtration system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It is also useful where the required dewpoint or air quality calls for a treatment package selected specifically for the application. If you do not already have appropriate air treatment, budget for it separately. Electrical service, feeder and disconnect sizing should be confirmed by a licensed electrician using the machine nameplate; Quincy does not publish a fixed breaker or amp requirement for this model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto-Dual and Smarter Running\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAuto-Dual control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e allows scheduled shutdowns, so the compressor does not run unnecessarily when there is no air demand. For a continuously rated machine, this is an easy way to reduce wasted energy during off-hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBelt Drive and Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elong-life V-belt drive\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Belts require periodic inspection, tension checks and eventual replacement, but they are simple and inexpensive to service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePremium synthetic lubricant is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the TEFC motor, low-oil shutdown and oil sight glass support longer service intervals. Note that this model's specifications do \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot list a pressure gauge\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e; ask us if one is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 76\" L × 25\" W × 58\" H\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 815 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReceiver:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Horizontal 120-gallon\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\/2\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 208-230\/460V, 3-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBreaker:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Sized by a licensed electrician according to the installation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops with existing air dryers and filtration\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need additional compressor capacity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication and machining operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with specific air-quality requirements.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMulti-bay service shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e replacing an older reciprocating compressor.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities with three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and available wall space for a horizontal package.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP, electric, TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFree air delivery\u003c\/th\u003e\n\u003ctd\u003e54.9 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e208-230\/460V, 3-phase, magnetic starter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmp draw \/ breaker\u003c\/th\u003e\n\u003ctd\u003eManufacturer states \"Consult Certified Electrician\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, oil-lubricated, long-life V-belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir treatment\u003c\/th\u003e\n\u003ctd\u003eNone fitted — no dryer and no aftercooler listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallon horizontal, 1\/2-inch outlet, no electronic drain valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e76 in x 25 in x 58 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e815 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQGS rotary screw compressor, long-life V-belt drive, 120-gallon horizontal receiver, TEFC motor, quiet enclosure, Auto-Dual control, air filter, oil sight glass, low-oil shutdown, magnetic starter and premium synthetic lubricant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout for your address. At \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e815 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, arrange a loading dock, suitable forklift or terminal pickup. Residential deliveries may incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStandard coverage is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 year for consumer and commercial use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. An extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-Year warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requires commissioning by a Quincy-authorized startup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45960283422773,"sku":"4152021976","price":11352.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Screenshot_2025-12-12_120924.jpg?v=1788283738"},{"product_id":"quincy-air-compressor-4103ds12vcb23-qt-120-gallon-two-stage","title":"Quincy Air Compressor 4103DS12VCB23 QT 120 Gallon Two Stage","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 10 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is Quincy’s straightforward 120-gallon shop compressor, built around a two-stage cast-iron pump, two-piece connecting rods, splash lubrication and a factory-fitted magnetic starter. The 230V, 3-phase motor drives the pump through a belt system, while a high-efficiency finned intercooler manages heat between compression stages. With a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI maximum pressure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a pump rated for more than 50,000 hours of service, it is designed for demanding shop air without adding features you may not need. Note: this configuration requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two-stage design compresses air in two steps, cooling it through the intercooler between stages before the high-pressure cylinder brings it to final pressure. That approach controls operating temperatures and makes sustained 175 PSI operation practical. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-piece connecting rods and splash-lubricated pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e also keep the mechanical design relatively simple, while the belt drive allows the pump to operate at a lower speed than the motor. An oil sight glass provides a quick way to monitor the lubrication level.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis model is best suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomotive service bays, tire shops, agricultural facilities and heavy-equipment workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where compressed air is primarily used for impact tools, ratchets, blowguns, lifts and other intermittent-demand equipment. The vertical 120-gallon receiver keeps the floor footprint to approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40\" × 30\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, but the unit stands about 75\" tall and weighs roughly 1,000 lbs dry, so plan for a solid, level slab, suitable anchoring, adequate service clearance and sufficient ventilation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot include an aftercooler, electronic tank drain or low-oil shut-off switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. That means more moisture can travel downstream, condensate must be drained manually and oil level requires routine inspection. For general shop air, those trade-offs may be acceptable; applications involving paint or plasma cutting should plan for appropriate downstream air treatment. The 1\" tank outlet, electrical circuit, site preparation and installation are the customer's responsibility, with breaker and conductor sizing determined by a certified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFewer Parts, Simpler Maintenance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-piece connecting rods\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e simplify the pump design and reduce potential wear points. The splash-lubricated system uses an oil sight glass for quick level checks, while the belt drive keeps pump speed lower and helps reduce crankshaft shock loads. Quincy rates the pump for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000+ hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Stage Compression at 175 PSI\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAir is compressed in two stages with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efinned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between them. Cooling the air before the second stage reduces heat and improves efficiency, allowing the compressor to reach \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reliably.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThree Features It Does Not Have\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNo aftercooler:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e More moisture can reach the air lines, so painting or plasma work may require additional drying.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNo electronic drain:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The receiver must be drained manually; an automatic drain can be added.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNo low-oil shutoff:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Oil level must be checked regularly through the sight glass.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 40\" × 30\" plus service clearance\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 75\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1,000 lbs dry\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230V, 3-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir outlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBreaker:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Sized by a certified electrician for your installation\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomotive service bays\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using impacts, ratchets and lifts.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTire and quick-service shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with intermittent heavy demand.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAgricultural and heavy-equipment workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using air tools.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eCommercial facilities with 230V three-phase power.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIncludes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon ASME-certified receiver, two-stage cast-iron pump, 10 HP motor, belt drive, magnetic starter, finned intercooler and oil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNo air dryer or aftercooler is included.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The EWK-4 Maintenance Kit for the extended warranty is sold separately and must be purchased with the compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor speed\u003c\/th\u003e\n\u003ctd\u003e1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical supply\u003c\/th\u003e\n\u003ctd\u003e230V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarter\u003c\/th\u003e\n\u003ctd\u003eMagnetic, with thermal overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStages\u003c\/th\u003e\n\u003ctd\u003eTwo, belt driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCylinders and heads\u003c\/th\u003e\n\u003ctd\u003eCast iron, aluminium heads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting rods\u003c\/th\u003e\n\u003ctd\u003eTwo-piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOil system\u003c\/th\u003e\n\u003ctd\u003eSplash lubricated, sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLow oil shut-off\u003c\/th\u003e\n\u003ctd\u003eNot fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntercooler\u003c\/th\u003e\n\u003ctd\u003eHigh-efficiency finned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eNot fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, vertical, ASME certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDrain valve\u003c\/th\u003e\n\u003ctd\u003eManual; no electronic drain fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverall size\u003c\/th\u003e\n\u003ctd\u003e40\" long by 30\" wide by 75\" high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,000 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit has an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME-certified tank\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with the required pressure relief valve and receiver fittings. It also carries a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA mark\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Our supplier data references an additional North American third-party electrical listing, but we have not confirmed it, so we will not claim it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf a specific electrical listing is required by your insurer or inspector, ask us to verify the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edata plate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, crated on a skid. Arrange a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eforklift or loading dock\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before delivery; terminal pickup is also available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential deliveries may incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the shipment before signing. Photograph any damage and record it on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eIncludes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for consumer and commercial use. Purchasing the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-4 Maintenance Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with the compressor and registering the unit with Quincy extends coverage to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year \"No Bull\" warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including on-site service and labor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45960286011445,"sku":"2020040776","price":6469.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/P2103DS12VCB23__57763.1679924335.1280.1280.webp?v=1788283867"},{"product_id":"quincy-air-compressor-4152021984-qgs-15-hp-120-gallon-rotary-screw","title":"Quincy Air Compressor 4152021984 QGS 15 HP 120 Gallon Rotary Screw","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQGS rotary screw compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers 54.9 CFM at 125 PSI with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving multi-bay shops continuous air for demanding tool use without relying on recovery periods. Its standout feature is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAuto-Dual operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which allows programmed shutdowns during periods of no demand and automatic restart when scheduled. An integrated refrigerated air dryer is also included, while the package uses a 120-gallon horizontal receiver. Note: this configuration requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208-230\/460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAuto-Dual addresses one of the less obvious costs of a rotary screw compressor: unnecessary standby operation. The compressor is designed to run continuously, but it does not need to maintain pressure all night when the shop is closed. Programmable shutdown lets the machine remain available during working hours and stop during predictable idle periods. When production resumes, it can restart without requiring someone to manually operate the compressor. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e54.9 CFM continuous output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is suited to several technicians using impact wrenches, ratchets, air hammers and blow guns, with additional capacity for equipment such as sanders or small blast cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe integrated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003erefrigerated air dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e handles moisture removal before compressed air enters the shop's distribution system. This model does not list an aftercooler, so the dryer carries the primary air-treatment load; keeping its condenser clean and confirming the required dewpoint before purchase are particularly important for demanding applications. A long-life V-belt drive provides straightforward service access, while premium synthetic lubrication is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. TEFC motor construction, low-oil shutdown on the engine and pump, and an oil sight glass support routine operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis package is well suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindependent automotive shops, fabrication and welding facilities, woodworking operations and other commercial shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with extended air demand and periods of predictable downtime. Its horizontal configuration measures 76\" long, 25\" wide and 58\" tall and weighs approximately 980 lbs, so it works well where wall length is available but floor width or ceiling height is limited. The receiver outlet is 1\/2\". Electrical service, feeder and disconnect sizing must be confirmed by a licensed electrician using the machine nameplate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Dryer for Moisture Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis model includes an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eintegrated refrigerated air dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, confirmed across the manufacturer's title, feature list and specifications. The dryer removes moisture, oil mist and debris before they reach your air lines and tools.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specifications also show \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eno aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, meaning the refrigerated dryer handles the moisture control on its own. Keep the dryer's condenser clean, and if you need a specific dewpoint for finishing or instrument air, confirm the requirement with us before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Life V-Belt Drive\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elong-life V-belt drive\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with premium synthetic lubricant rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The TEFC motor, quiet enclosure, low-oil shutdown and oil sight glass support reliable, low-maintenance operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 76\" L × 25\" W × 58\" H\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 980 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReceiver:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Horizontal 120-gallon\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\/2\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 208-230\/460V, 3-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBreaker:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Sized by a licensed electrician\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomotive shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e running air tools across multiple bays.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication and welding shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e needing dry air for plasma work.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWoodworking and cabinet shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where moisture can damage finishes.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities with variable demand\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that benefit from automatic shutdown during idle periods.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP, electric, TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFree air delivery\u003c\/th\u003e\n\u003ctd\u003e54.9 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e208-230\/460V, 3-phase, magnetic starter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmp draw \/ breaker\u003c\/th\u003e\n\u003ctd\u003eManufacturer states \"Consult Certified Electrician\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, oil-lubricated, long-life V-belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eNot fitted — see the note above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallon horizontal, 1\/2-inch outlet, no electronic drain valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir treatment\u003c\/th\u003e\n\u003ctd\u003eIntegrated refrigerated dryer plus air filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e76 in x 25 in x 58 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e980 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQGS rotary screw compressor, long-life V-belt drive, integrated refrigerated air dryer, 120-gallon horizontal receiver, TEFC motor, quiet enclosure, Auto-Dual control, air filter, oil sight glass, low-oil shutdown and premium synthetic lubricant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eNot included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e electronic drain valve. A pressure gauge is also not listed in the specifications; ask us if you need one at the receiver.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout for your address. At nearly \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,000 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, arrange a loading dock, forklift or terminal pickup. Residential deliveries may incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the crate, base rails and cabinet corners before signing, and record any damage on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStandard coverage is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 year for consumer and commercial use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-Year warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requires commissioning by a Quincy-authorized startup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45960376188981,"sku":"4152021984","price":15128.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152021984__37307.1679834830.1280.1280.webp?v=1788285441"},{"product_id":"quincy-air-compressor-4152026525-qgs-20-hp-132-gallon-rotary-screw-208-230-460v-3-phase","title":"Quincy Air Compressor 4152026525 QGS 20 HP 132 Gallon Rotary Screw 208-230\/460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQGS rotary screw compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers 54.9 CFM at 125 PSI with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving multi-bay shops continuous air for demanding tool use without relying on recovery periods. Its standout feature is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAuto-Dual operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which allows programmed shutdowns during periods of no demand and automatic restart when scheduled. An integrated refrigerated air dryer is also included, while the package uses a 120-gallon horizontal receiver. Note: this configuration requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208-230\/460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAuto-Dual addresses one of the less obvious costs of a rotary screw compressor: unnecessary standby operation. The compressor is designed to run continuously, but it does not need to maintain pressure all night when the shop is closed. Programmable shutdown lets the machine remain available during working hours and stop during predictable idle periods. When production resumes, it can restart without requiring someone to manually operate the compressor. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e54.9 CFM continuous output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is suited to several technicians using impact wrenches, ratchets, air hammers and blow guns, with additional capacity for equipment such as sanders or small blast cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe integrated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003erefrigerated air dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e handles moisture removal before compressed air enters the shop's distribution system. This model does not list an aftercooler, so the dryer carries the primary air-treatment load; keeping its condenser clean and confirming the required dewpoint before purchase are particularly important for demanding applications. A long-life V-belt drive provides straightforward service access, while premium synthetic lubrication is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. TEFC motor construction, low-oil shutdown on the engine and pump, and an oil sight glass support routine operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis package is well suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindependent automotive shops, fabrication and welding facilities, woodworking operations and other commercial shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with extended air demand and periods of predictable downtime. Its horizontal configuration measures 76\" long, 25\" wide and 58\" tall and weighs approximately 980 lbs, so it works well where wall length is available but floor width or ceiling height is limited. The receiver outlet is 1\/2\". Electrical service, feeder and disconnect sizing must be confirmed by a licensed electrician using the machine nameplate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eConfirm the Dryer Before Ordering\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003ePublished information conflicts on the \u003cstrong\u003eintegrated refrigerated dryer\u003c\/strong\u003e. The feature list and description say one is included, while the specification table says \u003cstrong\u003e“No.”\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf a built-in dryer is important, \u003cstrong\u003eask us to confirm the factory configuration before ordering\u003c\/strong\u003e. The specifications do confirm an \u003cstrong\u003eaftercooler\u003c\/strong\u003e, which reduces discharge temperature and removes bulk moisture, but does not provide the same dewpoint as a refrigerated dryer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for Continuous Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e100% duty cycle\u003c\/strong\u003e and oil-injected twin-screw airend are designed for continuous operation. Premium synthetic lubricant is rated for \u003cstrong\u003e8,000 hours\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAdditional features include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eTEFC IP55 motor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWye-Delta reduced-voltage starter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eLow-oil shutdown\u003c\/li\u003e\n\u003cli\u003eOil sight glass\u003c\/li\u003e\n\u003cli\u003eSpin-on fluid filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 74\" L × 30.7\" W × 72.2\" H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1,184 lbs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReceiver outlet:\u003c\/strong\u003e 1\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 208-230\/460V, 3-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStarter:\u003c\/strong\u003e Magnetic starter included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaker:\u003c\/strong\u003e Sized by a licensed electrician\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomotive and truck shops\u003c\/strong\u003e running multiple air tools.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFabrication and light production\u003c\/strong\u003e requiring steady air pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-term operators\u003c\/strong\u003e seeking lower routine maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-phase facilities\u003c\/strong\u003e with adequate electrical service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e20 HP, electric, TEFC with IP 55 wash-down protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e208-230\/460V, 3-phase, Wye-Delta start, magnetic starter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmp draw \/ breaker\u003c\/th\u003e\n\u003ctd\u003eManufacturer states \"Consult Certified Electrician\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, oil-lubricated, gear drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eFitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e132 gallon horizontal, 1 inch outlet, no electronic drain valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e74 in x 30.7 in x 72.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,184 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eWhat's Included\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGear-driven \u003cstrong\u003eQGS rotary screw compressor\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInfologic2 Basic Controller\u003c\/strong\u003e with display\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTEFC IP55 motor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132-gallon horizontal receiver\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAftercooler\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eAir filter and pressure gauge\u003c\/li\u003e\n\u003cli\u003eOil sight glass\u003c\/li\u003e\n\u003cli\u003eMagnetic starter\u003c\/li\u003e\n\u003cli\u003eLow-oil shutdown\u003c\/li\u003e\n\u003cli\u003eSpin-on fluid filter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eShipping \u0026amp; Delivery\u003c\/h3\u003e\n\u003cp\u003eShips by \u003cstrong\u003efreight to the lower 48 states\u003c\/strong\u003e, with shipping calculated at checkout.\u003c\/p\u003e\n\u003cp\u003eDue to the \u003cstrong\u003e1,184-lb weight and 6+ ft height\u003c\/strong\u003e, arrange a loading dock, suitable forklift, or terminal pickup. Residential deliveries incur an additional fee.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1-year consumer warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1-year commercial warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eOptional \u003cstrong\u003e3-year extended factory warranty\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Blue 5-Year warranty\u003c\/strong\u003e with Quincy-authorized startup\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45960401748021,"sku":"4152026525","price":18854.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152026525__16339.1679922391.1280.1280.webp?v=1788286216"},{"product_id":"quincy-air-compressor-4152026529-qgs-25-hp-132-gallon-rotary-screw-208-230-460v-3-phase","title":"Quincy Air Compressor 4152026529 QGS 25 HP 132 Gallon Rotary Screw 208-230\/460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e25 HP QGS\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers higher compressor capacity without increasing the footprint of the smaller versions in this package. It measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e74\" long, 30.7\" wide and 72.2\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and uses a 132-gallon horizontal receiver, making it a practical way to add air capacity without changing an existing QGS installation area. The oil-injected twin screw airend is rated for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the gear-driven transmission and TEFC motor are built for continuous commercial operation. Note: requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208-230\/460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egear drive\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e transfers motor power directly through a geared transmission rather than a belt system, eliminating routine belt tension checks and replacement. Premium synthetic lubrication is specified for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a spin-on fluid filter, air filter and oil sight glass supporting routine maintenance. The TEFC motor carries \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIP 55 wash-down protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and Wye-Delta reduced-voltage starting helps control electrical inrush. Low-oil shutdown is fitted on both the engine and pump to protect the compressor if lubrication falls below the required level.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Infologic2 Basic controller adds useful operating and expansion controls, including \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eprogrammable auto-restart, remote start\/stop and sequencing for up to six QGS compressors in the 20–30 HP range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. That allows this 25 HP unit to operate as part of a coordinated compressor group if air demand grows later. The display provides operating information including pressure, temperature, dewpoint and motor start limits. An aftercooler is specified, but published information conflicts on whether an integrated refrigerated dryer is included, so confirm the dryer configuration with us before ordering if it is important to your application.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis package is suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eproduction shops, fabrication facilities, machining operations and heavy automotive applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where several air-consuming tools may operate simultaneously. It is also appropriate for facilities planning a future sequenced compressor installation. The 1\" receiver outlet should be considered when sizing distribution piping. Allow adequate clearance around the hinged and removable service panels, and have a licensed electrician size the electrical service, feeder and disconnect from the machine nameplate; Quincy does not publish a fixed amp or breaker requirement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConfirm the Air Dryer Before Ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished information conflicts on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eintegrated refrigerated dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The manufacturer's feature list and marketing description say one is included, while the specification table says \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e“No.”\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf air drying is important, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e so we can confirm the current factory configuration. The unit does include an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eaftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which reduces discharge temperature and removes bulk moisture, but it does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provide the same dewpoint as a refrigerated dryer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for Continuous Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed for continuous operation. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTEFC IP55 motor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, Wye-Delta reduced-voltage starting and low-oil shutdown support reliable operation in demanding shop environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eInfologic2 Basic controller\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides programmable auto-restart, remote start\/stop, and monitoring of pressure, temperature, dewpoint and motor limits. It can also sequence up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esix QGS compressors from 20–30 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 74\" L × 30.7\" W × 72.2\" H\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1,201 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReceiver outlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 208-230\/460V, 3-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStarter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Magnetic starter included\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBreaker:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Consult a certified electrician\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduction shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e needing more capacity without a larger footprint.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication, machining and heavy automotive\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e work with multiple high-demand tools.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eFacilities planning a sequenced compressor system.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e25 HP, electric, TEFC with IP 55 wash-down protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e208-230\/460V, 3-phase, Wye-Delta start, magnetic starter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmp draw \/ breaker\u003c\/th\u003e\n\u003ctd\u003eManufacturer states \"Consult Certified Electrician\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, oil-lubricated, gear drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eFitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e132 gallon horizontal, 1 inch outlet, no electronic drain valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e74 in x 30.7 in x 72.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,201 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's Included\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eQGS rotary screw compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with gear-driven airend\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eInfologic2 Basic Controller\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with display\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eTEFC IP55 motor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e132-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAftercooler, air filter and pressure gauge\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpin-on fluid filter\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic drain valve is not included\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e; draining is manual unless an automatic valve is added. The refrigerated dryer remains the disputed item noted above.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDue to the unit's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,200+ lb weight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, arrange a loading dock, properly rated forklift, or terminal pickup. Residential deliveries incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the crate before signing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and record any damage on the bill of lading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e1-year consumer warranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e1-year commercial warranty\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eOptional \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year extended factory warranty\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-Year warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with Quincy-authorized startup\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45964063146037,"sku":"4152026529","price":22676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152026529__92724.1679922331.1280.1280.webp?v=1788352813"},{"product_id":"quincy-air-compressor-4153d12hca20m-qt-max-15-hp-120-gallon-two-stage-208v-3-phase","title":"Quincy Air Compressor 4153D12HCA20M QT Max 15 HP 120 Gallon Two Stage 208V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QT MAX 15 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e51 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% continuous-duty rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it built for sustained shop air demand rather than short bursts. The package combines a 15 HP motor with a splash-lubricated, cast-iron two-stage pump, a 120-gallon horizontal receiver, and a conservative 1,750 RPM operating speed. Quincy rates the pump for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emore than 50,000 hours of service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving this compressor the capacity and operating design needed when multiple air-powered tools may be running throughout the day.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with connecting-rod dippers circulating oil through the crankcase. This straightforward system reduces the number of components involved in lubrication, while the oil sight glass makes the level easy to check. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil cutoff switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e shuts the compressor down if the oil level becomes too low, helping protect the pump from damage. Heat management is also built around continuous operation: a high-efficiency finned intercooler cools the air between compression stages, while built-in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercoolers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduce discharge temperature before air enters the receiver and help remove moisture from the compressed air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor electrical protection, the unit includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The 15 HP motor draws 48.3 amps according to Quincy’s published information, while the 1-inch tank outlet provides the connection point for the shop’s compressed-air system. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 15 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a strong fit for multi-bay automotive shops, dealerships, tire and fleet operations, fabrication facilities, and other professional environments where several technicians may depend on consistent air supply. Its 100% duty cycle makes it particularly useful for shops that have outgrown compressors that need frequent recovery periods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSplash Lubrication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash-lubricated pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a simple, low-component design. Connecting-rod dippers circulate oil through the crankcase, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e makes level checks easy and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil cut-off\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e protects the pump from damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for Heat Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efinned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e cools air between compression stages, reducing second-stage workload and valve temperatures. Built-in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercoolers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e lower discharge temperature and condense much of the moisture before it reaches the tank and air system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps protect the three-phase motor from overload and phase-loss conditions. Combined with the low-oil cut-off, it provides protection against common compressor failures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 78\" L × 28\" W × 55\" H\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 923 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 208V, 3-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAmp draw:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 48.3 A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir connection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 51 CFM\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eMulti-bay service centers and dealerships\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eTire and fleet operations\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eFabrication shops and spray booths\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShops needing sustained air volume throughout the day\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e15 HP two-stage cast-iron pump\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in air-cooled aftercoolers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-efficiency finned intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil cut-off switch\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir delivery\u003c\/th\u003e\n\u003ctd\u003e51 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003eContinuous, 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e208V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw (as listed by Quincy)\u003c\/th\u003e\n\u003ctd\u003e48.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage cast iron, splash lubricated, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump speed\u003c\/th\u003e\n\u003ctd\u003e1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e78\" long × 28\" wide × 55\" tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e923 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor protection\u003c\/th\u003e\n\u003ctd\u003eMagnetic starter with thermal overload; low-oil cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ereceiver is built to the ASME pressure-vessel code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the specification record also lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These certifications apply to the tank, not necessarily the complete compressor assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBefore You Order — Please Confirm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWarranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published information shows two different warranty structures. One lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory coverage extending to 3-year “No Bull” coverage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Another lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year parts and labor, 2-year package and 3-year pump coverage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, conditional on purchasing and registering an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-5 Maintenance Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eContact us to confirm the current factory terms in writing before ordering.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic tank drain:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published specifications conflict on whether an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic automatic drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is included. Confirm with us if this feature is important to you.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e923 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the unit requires a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eforklift, loading dock or terminal pickup\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Residential deliveries incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the compressor before signing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and record any damage on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause the published warranty terms conflict, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm the applicable coverage before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The baseline listed is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory coverage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with extended protection available under specific conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45964077203509,"sku":"2020040894","price":9591.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2153D12HCA20M__75580.1679839687.1280.1280.png?v=1788353421"},{"product_id":"quincy-air-compressor-4153ds12hca20-qt-pro-15-hp-120-gallon-two-stage-208v-3-phase","title":"Quincy Air Compressor 4153DS12HCA20 QT Pro 15 HP 120 Gallon Two Stage 208V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QT Pro 15 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e produces \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e51 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e while the pump operates at just \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e923 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e—a notably slow speed for a reciprocating compressor with this output. Instead of relying on high shaft speed to produce airflow, the four-cylinder, splash-lubricated cast-iron pump uses greater displacement, helping reduce the number of piston cycles accumulated during continuous operation. Quincy rates the pump for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emore than 50,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while an industrial Baldor motor provides the drive on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a 100% duty rating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe low pump speed has practical benefits beyond longevity. Fewer piston cycles mean less repeated movement between the rings and cylinder walls, while the slower operation also helps reduce heat and vibration compared with a faster-running pump. The QT Pro is also designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil carry-over below 5 PPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping keep compressed air cleaner for downstream equipment and applications where oil contamination is a concern. A fin-and-tube intercooler controls temperature between compression stages, while \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estainless steel reed valves\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, cast-iron cylinders, and an aluminum head complete the two-stage pump assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor day-to-day operation, the compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efactory-fitted magnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, along with a low-oil shut-off and oil sight glass for straightforward monitoring. The unit is built around a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and uses a 1-inch air outlet for connection to the shop's compressed-air piping. With its combination of slow pump speed, high output, low oil carry-over, and continuous-duty design, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 15 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is suited to automotive service shops, fabrication facilities, tire and truck operations, and professional shops that need sustained compressed air from a single receiver.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Slow Actually Buys\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe QT Pro uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eslow-speed four-cylinder pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, reducing piston wear, heat and vibration compared with higher-speed designs. It also produces a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elower-frequency, quieter sound\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it better suited to continuous shop use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCleaner Compressed Air\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5 PPM oil carry-over\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping protect paint finishes, pneumatic tools and downstream piping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOther features include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCast-iron cylinders with aluminum head\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStainless steel reed valves\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFin-and-tube intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shut-off\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReceiver:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 120-gallon horizontal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 78\" L × 28\" W × 55\" H\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 995 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 208V, 3-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStarter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Magnetic starter included\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomotive and fabrication shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e running multiple stations.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTire and truck service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using high-demand impact tools.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBody and refinishing shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e needing low oil carry-over.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops adding a second compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for long-term capacity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Arrives\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe assembled package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efour-cylinder cast-iron two-stage pump, Baldor motor, horizontal receiver, magnetic starter, oil sight glass, low-oil shut-off and intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOil, hoses, filtration, dryers, regulators and isolation valves are not listed as included.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy EWK-5 Maintenance Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is also sold separately and may be required for the extended warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP industrial-duty Baldor, 208V, 3-phase, magnetic starter fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump speed\u003c\/th\u003e\n\u003ctd\u003e923 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDelivery\u003c\/th\u003e\n\u003ctd\u003e51 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty\u003c\/th\u003e\n\u003ctd\u003e100% continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, four-cylinder cast iron with aluminum head, splash lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir quality\u003c\/th\u003e\n\u003ctd\u003eOil carry-over below 5 PPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal, 1-inch outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e78 inches long, 28 inches wide, 55 inches high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e995 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor carries \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME, UL and CSA marks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The ASME certification applies to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressure vessel\/receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the electrical marks apply to the motor and controls.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese certifications do not replace local permits or required pressure-vessel inspections. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eConfirm your local requirements before installation.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eArrange a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eforklift, loading dock or telehandler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, or choose terminal pickup. Residential deliveries incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and record any damage on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIncludes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty on parts and labor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Coverage can be extended by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eregistering the unit with Quincy and purchasing the EWK-5 Maintenance Kit at the time of purchase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with extended pump coverage and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” protection with on-site service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45964292816949,"sku":"2020040886","price":8295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2153DS12HCA20__66667.1679852986.1280.1280.jpg?v=1788354177"},{"product_id":"quincy-air-compressor-4153ds12hca23-qt-pro-15-hp-120-gallon-two-stage","title":"Quincy Air Compressor 4153DS12HCA23 QT Pro 15 HP 120 Gallon Two Stage","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QT Pro 15 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is built for shops that need clean, consistent compressed air rather than just tank capacity. Its cast-iron four-cylinder pump delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e51 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is specified to maintain \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil carry-over below 5 PPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping reduce contamination in air lines, pneumatic equipment and finishing applications. Operating across a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e145–175 PSI range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this 230V three-phase package is mounted on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and powered by an industrial-duty Baldor motor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe low oil carry-over specification is one of the key differences between this compressor and basic shop units. While all oil-lubricated compressors transfer a small amount of oil into the air stream, keeping that level below 5 PPM helps protect paint finishes, adhesives, pneumatic valves and air tools from long-term contamination. The pump’s two-stage design splits compression between multiple cylinders, allowing it to produce its rated output with controlled operating temperatures and reduced stress. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-inch ball valve outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a full-size connection point for the shop air system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe mechanical package is designed for long-term commercial use. The Baldor motor is built for industrial-duty operation, while the cast-iron four-cylinder pump is rated by Quincy for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emore than 50,000 hours of service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A factory-installed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps protect the motor from overload conditions and phase-related electrical issues common in three-phase environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 15 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is suited for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebody shops, fabrication facilities, machine shops and multi-bay automotive operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that rely on a central compressed-air system. Its horizontal 120-gallon receiver measures 78\" long, 28\" wide and 55\" high, making it a practical choice for shops with available floor length but limited ceiling height. Electrical service, breaker sizing and installation requirements should be confirmed with a certified electrician before delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLow Oil Carry-Over\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eless than 5 PPM oil carry-over\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping protect paint finishes, pneumatic tools and downstream piping from contamination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWorking Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWorking range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 145–175 PSI\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\" full-port ball valve\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for Long-Term Use\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindustrial-duty Baldor motor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e drives a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron four-cylinder, two-stage pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rated for more than \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A factory-installed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides thermal overload protection for the motor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReceiver:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 120-gallon horizontal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 78\" L × 28\" W × 55\" H\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 995 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230V, 3-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStarter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Magnetic starter included\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBody and refinishing shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e needing clean compressed air.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMulti-bay workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with 230V three-phase power.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMachine and fabrication shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using pneumatic equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShops replacing compressors that caused oil contamination in their air lines.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Arrives\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe assembled package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efour-cylinder cast-iron pump, Baldor motor, horizontal receiver, magnetic starter and 1\" ball valve outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eOil, hose, filtration, dryers, regulators and downstream isolation valves are not listed as included.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP industrial-duty Baldor, 230V, 3-phase, magnetic starter fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage cast iron, four cylinder, belt driven\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDelivery\u003c\/th\u003e\n\u003ctd\u003e51 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking pressure\u003c\/th\u003e\n\u003ctd\u003e145 to 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir quality\u003c\/th\u003e\n\u003ctd\u003eOil carry-over below 5 PPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal, 1-inch ball valve outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e78 inches long, 28 inches wide, 55 inches high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e995 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory, extending to the 3-year No Bull cover on registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eConfirm Before Ordering\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eReceiver size:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The title, page copy and manufacturer specifications list a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, but one specification entry shows a smaller tank. If tank capacity affects your sizing, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us to confirm it with Quincy before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eModel number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The heading and specifications list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4153DS12HCA23\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the page URL uses a different prefix. If you need to match a specific part number, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm it with us before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is listed with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME, UL and CSA marks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. ASME certification applies to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressure vessel\/receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while UL and CSA apply to the electrical components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese certifications do not cover air quality, replace local permits or eliminate required pressure-vessel inspections. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCheck your local requirements before installation.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eArrange a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eforklift, loading dock or terminal pickup\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Residential deliveries incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and record any damage on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIncludes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, extendable to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when the unit is registered with Quincy and maintained with Quincy kits.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45964452069429,"sku":"2020040887","price":8295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2153DS12HCA23__74982.1679925702.1280.1280.webp?v=1788354718"},{"product_id":"quincy-air-compressor-451c80vcbm-qt-max-5-hp-80-gallon-two-stage-230v-1-phase","title":"Quincy Air Compressor 451C80VCBM QT Max 5 HP 80 Gallon Two Stage 230V 1 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy 5 HP QT Pro\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines a long-life reciprocating pump with the convenience of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it a practical choice for shops without three-phase service. Its splash-lubricated cast-iron two-stage pump is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000+ hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, supported by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5-year pump warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and uses an extra-capacity oil reserve with low-oil protection. The package also includes an industrial-duty 5 HP motor, an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon vertical ASME receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, factory-installed magnetic starter, finned intercooler, and air-cooled aftercooler.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump is designed around three factors that directly affect service life: operating speed, heat, and lubrication. Its deliberately slow-running design reduces the repeated movement and friction experienced by the piston components, while the cast-iron construction helps manage operating temperatures. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e cools air between the two compression stages, reducing the heat entering the second stage. The air-cooled aftercooler then lowers discharge temperature before the compressed air reaches the receiver, helping condense moisture at the machine. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil cutout and oil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e make it easier to monitor lubrication and shut the compressor down before insufficient oil causes serious pump damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V 1-phase electrical requirement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the QT Pro 5 HP avoids the need for three-phase service while still providing an industrial-style compressor package. The vertical 80-gallon receiver keeps the footprint compact at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with an overall height of 74\" and an assembled weight of 680 lbs. A factory magnetic starter provides motor thermal overload protection. This configuration fits \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindependent automotive and tire shops, single-phase workshops, restoration garages, woodworking operations, and serious home garages\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need a durable compressor without upgrading their building to three-phase power. Before ordering, confirm the available electrical service, ceiling clearance, access route, and floor capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSingle-Phase Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V 1-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e model is ideal for shops without three-phase service. A factory-fitted \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides motor thermal overload protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBreaker sizing is not published; have a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecertified electrician\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e size the protection based on your service and cable run before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 37\" × 24\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 74\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 680 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReceiver:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 80-gallon vertical\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for Long Life\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe slow-speed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron two-stage pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed for long service life, with aluminum heads, a finned intercooler and an air-cooled aftercooler.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAdditional features include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eExtra-capacity oil reserve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shut-off\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-piece connecting rods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-efficiency intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir-cooled aftercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSingle-phase workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e needing more capacity.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIndependent service and tire shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e running air equipment daily.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHome and restoration shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e wanting long-term durability.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWoodworking and finishing shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e needing steady air up to 175 PSI.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e5 HP industrial motor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCast-iron two-stage pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon vertical ASME receiver\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFinned intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir-cooled aftercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExtra-capacity oil reserve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGauges\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput \u0026amp; Pump\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V 1-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure\u003c\/td\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump\u003c\/td\u003e\n\u003ctd\u003eTwo-stage, splash lubricated, cast iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eLow oil shutdown, magnetic starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAftercooler\u003c\/td\u003e\n\u003ctd\u003eAir-cooled, fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTank \u0026amp; Dimensions\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver\u003c\/td\u003e\n\u003ctd\u003e80 gallon, vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank outlet\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e37\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e74\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e680 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe data lists an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA electrical marks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The feature list also states the unit is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuilt in the USA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe do not have documentation confirming a third-party safety listing for the complete assembled machine. If your insurer or purchasing requirements call for one, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us to verify it with the manufacturer before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e680 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, you will need suitable unloading equipment or can arrange terminal pickup. Residential deliveries incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and record any damage on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished information lists a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” extension\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e under manufacturer conditions, and a separately stated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5-year pump warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause the terms may overlap differently, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm the applicable coverage in writing before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\" target=\"_blank\" title=\"Quincy Air Compressor 451C80VCBM QT Max 5 HP 80 Gallon Two Stage 230V 1 Phase Manual\" rel=\"noopener\"\u003eDownload Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45964556271669,"sku":"451CS80VCBM","price":4504.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/253D80VCB23M__61890.1684437985.1280.1280.webp?v=1788355473"},{"product_id":"quincy-air-compressor-451cs80hcb-qt-pro-5-hp-80-gallon-two-stage-230v-1-phase","title":"Quincy Air Compressor 451CS80HCB QT Pro 5 HP 80 Gallon Two Stage 230V 1 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QT Pro 5 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e17.2 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e from a deliberately slow-running pump turning at just \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e942 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. That low pump speed is a defining feature of this industrial reciprocating design, reducing piston travel, friction, heat, and operating noise compared with faster compressors at the same horsepower. The two-stage, cast-iron QT-5 pump is mounted on an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and operates on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so it does not require three-phase service. Note: Quincy specifies a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60-amp breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe slow-running design is backed by a pump built for long-term service. Cast-iron construction provides the mass and durability needed for a compressor designed to accumulate hours rather than simply maximize output from a compact package. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTwo-piece connecting rods\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e allow service without removing the crankshaft, while finned cooling helps manage operating temperatures. Compression takes place in two stages, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned-tube intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between them to cool the air before it enters the second stage. The result is a 175 PSI working pressure that gives the compressor enough reserve for demanding pneumatic equipment without relying on high pump speed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efactory-installed magnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides contactor switching and motor overload protection, while the open drip-proof motor is suited to a reasonably clean, dry installation environment. The horizontal receiver keeps the unit relatively low at approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e70\" long × 23\" wide × 47\" high\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a 3\/4\" tank outlet. With 17.2 CFM available, this compressor is well suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eone- and two-bay automotive shops, tire and quick-service operations, farm workshops, small fabrication shops, and serious home garages\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need industrial-style construction on standard single-phase power. For shops running several high-consumption tools simultaneously, compare total CFM demand against the compressor's output before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSingle-Phase Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis QT Pro runs on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esingle-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and requires a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60-amp breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Confirm your electrical service can support it before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA factory-fitted \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides contactor switching and motor overload protection. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eopen drip-proof motor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e should be installed in a clean, dry location.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSlow-Speed, Long-Life Pump\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump runs at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e942 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, reducing noise, heat and component wear compared with high-speed designs. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron QT-5 industrial pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e uses finned cooling and serviceable two-piece connecting rods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Stage Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e17.2 CFM\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI maximum pressure\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e3\/4\" tank outlet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approx. 70\" L × 23\" W × 47\" H\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approx. 660 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eReceiver:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 80-gallon horizontal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Single-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBreaker:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 60 A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3\/4\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOne- and two-bay shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e without three-phase power.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHome and hobby workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where low noise matters.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTire and quick-service bays\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using impact tools.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eSmall fabrication and farm workshops.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShops replacing high-speed compressors with a quieter, slower-running design.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eQT-5 cast-iron two-stage pump\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFinned-tube intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBelt guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOpen drip-proof slow-speed motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGauges and oil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSafety relief valve\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eASME-coded 80-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e5 HP, 230V, 1-Phase, open drip-proof, magnetic starter fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump speed\u003c\/th\u003e\n\u003ctd\u003e942 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003e17.2 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eQT-5 two-stage cast iron, belt drive, splash lubricated, two-piece connecting rods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003e80-gallon horizontal, ASME coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e70\" long × 23\" wide × 47\" high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e660 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCircuit\u003c\/th\u003e\n\u003ctd\u003e60 Amp breaker specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tank is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME coded\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the specification lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for the electrical components. These certifications do not cover installation or replace local inspection and insurance requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFreight \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight on a pallet to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. At approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e660 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, you will need a forklift or pallet jack, or can arrange terminal pickup with a suitable trailer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential delivery is available for an additional fee, with freight calculated at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and record any damage on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIncludes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, extendable to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e under Quincy's conditions, including registration and, on some models, a maintenance kit purchased with the compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45964616663093,"sku":"2020040800","price":3863.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/251CS80HCB23__31585.1679837610.1280.1280.webp?v=1788356114"},{"product_id":"quincy-air-compressor-453d80vcb20m-qt-max-5-hp-80-gallon-two-stage-208v-3-phase","title":"Quincy Air Compressor 453D80VCB20M QT Max 5 HP 80 Gallon Two Stage 208V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QT MAX 5 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a 208V three-phase compressor built around a splash-lubricated, cast-iron two-stage pump that delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e17.2 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It pairs that output with an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon vertical ASME receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, factory-installed magnetic starter, and air-cooled aftercooler in a compact vertical package. Unlike models designed for multiple electrical configurations, this build is specifically for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V 3-phase service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so verify the voltage available at your panel before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe integrated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps manage one of the biggest challenges in compressed-air systems: moisture. Compression heats the air and increases its moisture content, so cooling it before it enters the receiver causes much of that water to condense at the machine instead of traveling through the shop's air lines. That can reduce moisture reaching filters, dryers, and pneumatic tools while helping protect downstream equipment and finishing work. The pump also uses a finned intercooler between compression stages to control heat, while its slow operating speed, oversized oil reservoir, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil shutdown\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e are designed to support long service life. Quincy rates the pump for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emore than 50,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe QT MAX's cast-iron pump uses aluminum heads and two-piece connecting rods, with the factory magnetic starter providing \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emotor thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The vertical receiver keeps the footprint to approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the overall height is 74\" and assembled weight is 680 lbs. This configuration is well suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecommercial automotive shops, fabrication facilities, paint and body operations, and other professional workplaces\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with 208V three-phase power. Before purchasing, confirm your building's electrical supply, available ceiling height, access route, and floor capacity. If an automatic tank drain is important to your installation, confirm the current configuration with us before ordering, as the available product information is inconsistent on that feature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Disclosures Before Ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eModel code:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The title and specifications list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e453D80VCB20M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the description and URL show \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e253D80VCB20M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Please provide the model code on your quote so we can confirm the correct build with the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eTank drain:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The feature list and detailed specifications show an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic electronic drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, but another field says it is not included. If an automatic drain is important, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us to confirm it in writing before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 37\" × 24\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 74\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 680 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 208V, 3-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStarter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Magnetic starter included\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy the Aftercooler Matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduces discharge temperature and condenses much of the moisture before air enters the receiver. This helps protect piping, filters and pneumatic equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSlow, Heavy \u0026amp; Protected\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron two-stage pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e uses aluminum heads, a finned intercooler and slow-speed operation for lower heat, friction and noise. The pump is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000+ hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo-piece connecting rods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOversized oil reservoir\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e208V three-phase commercial shops\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomotive workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with multiple bays\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003ePaint and body shops\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using plasma cutters, grinders or blast equipment\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo-stage cast-iron pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e5 HP motor\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon vertical ASME receiver\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFinned intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir-cooled aftercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGauges\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir delivery\u003c\/td\u003e\n\u003ctd\u003e17.2 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure\u003c\/td\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump\u003c\/td\u003e\n\u003ctd\u003eTwo-stage, splash lubricated, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAftercooler\u003c\/td\u003e\n\u003ctd\u003eAir-cooled, fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePower, Tank \u0026amp; Size\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e208V 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver\u003c\/td\u003e\n\u003ctd\u003e80 gallon, vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank outlet\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFootprint\u003c\/td\u003e\n\u003ctd\u003e37\" by 24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e74\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e680 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur data lists an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e coverage on the electrical side. The feature list also states that the unit is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuilt in the USA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe do not claim a third-party safety listing for the complete machine assembly. Component approvals are not the same as a certification for the finished unit. If your insurer or purchasing requirements call for a specific listing, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask before ordering and we will confirm it with the manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFreight shipping is available throughout the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the rate quoted at checkout based on your address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan the unloading in advance:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eForklift or loading dock preferred\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTerminal pickup available if needed\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResidential delivery carries an additional fee\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the pallet, crate, tank, gauges and starter enclosure. Record any damage on the bill of lading \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ein front of the driver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before accepting the shipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty covering parts and labor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Purchasing the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-3 maintenance kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with the compressor and registering promptly can extend coverage under Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year \"No Bull\" Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including on-site service. The extended coverage must be arranged \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eat the time of purchase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45964636127285,"sku":"453D80VCB20M","price":4504.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/253D80VCB20M__97594.1679853230.1280.1280.webp?v=1788357037"},{"product_id":"quincy-air-compressor-453d80vcb23m-qt-max-5-hp-80-gallon-230v-3-phase","title":"Quincy Air Compressor 453D80VCB23M QT Max 5 HP 80 Gallon 230V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 5 HP compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is built for shops that need reliable compressed air without babysitting the machine. Its slow-running, cast iron \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers 17.2 CFM at 175 PSI, while the protection package adds a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil shutdown switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, oversized oil reservoir, and factory magnetic starter with thermal overload. The 80-gallon vertical ASME receiver and air-cooled aftercooler complete a setup designed for sustained shop use. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRequires 230V 3-Phase power.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe standout feature is the pump's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eslow-rotation design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which reduces the heat and friction associated with higher-speed compressor pumps. Cast iron construction, aluminum heads, stainless steel reed valves, and a finned intercooler work together to control operating temperatures between compression stages. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e then lowers the temperature of the compressed air before it reaches the tank, helping moisture condense in the receiver instead of throughout your downstream piping. The result is cleaner air reaching your tools and less moisture for filters, dryers, and air lines to handle.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis compressor is a practical choice for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomotive and truck service shops, fabrication operations, light manufacturing, and other 230V three-phase workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with steady compressed-air demand. Its combination of slow pump operation, cooling, and automatic protection makes it particularly well suited to installations where the compressor may run for long periods with limited operator attention.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Things to Confirm Before Ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The title and specifications list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e453D80VCB23M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the description and page URL list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e253D80VCB23M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Send us the code on your quotation so we can confirm the exact build with the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAutomatic tank drain:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published details conflict. The feature list and detailed specifications show an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic automatic drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while another field says no drain is fitted. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAsk us to confirm this in writing before ordering.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFitting It \u0026amp; Power Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis vertical unit measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\" × 74\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e680 lbs assembled\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Confirm ceiling clearance, delivery access and floor capacity before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230V, 3-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eStarter:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Magnetic starter included\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBreaker:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not specified; consult a certified electrician\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSlow-Speed, Heavy-Duty Pump\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eslow-speed cast-iron pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is designed to reduce heat and wear. Aluminum heads, a finned intercooler and two-stage cooling help control operating temperatures, while the manufacturer rates the pump for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000+ hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAdditional features include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo-piece connecting rods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStainless steel reed valves\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOversized oil reservoir\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAir-Cooled Aftercooler\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduces discharge temperature and condenses moisture before air enters the tank. This helps reduce condensate in downstream piping and lowers the load on filters and dryers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn aftercooler is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot a substitute for a refrigerated dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e if your application requires dried air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePlant rooms and unattended installations\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e230V three-phase workshops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomotive and truck service shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFabrication and light manufacturing\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCast-iron two-stage pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e5 HP motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e80-gallon vertical ASME receiver\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFinned intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir-cooled aftercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOversized oil reservoir\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGauges\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir delivery\u003c\/td\u003e\n\u003ctd\u003e17.2 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure\u003c\/td\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump\u003c\/td\u003e\n\u003ctd\u003eTwo-stage, splash lubricated, cast iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow oil shutdown\u003c\/td\u003e\n\u003ctd\u003eFitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic starter\u003c\/td\u003e\n\u003ctd\u003eFitted, thermal overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil sight glass\u003c\/td\u003e\n\u003ctd\u003eFitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAftercooler\u003c\/td\u003e\n\u003ctd\u003eAir-cooled, fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePower, Tank \u0026amp; Size\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver\u003c\/td\u003e\n\u003ctd\u003e80 gallon, vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank outlet\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFootprint\u003c\/td\u003e\n\u003ctd\u003e37\" by 24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e74\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e680 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur data lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for the receiver and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for the electrical side. The feature list also states \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUS manufacture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe do not claim a third-party listing for the complete assembled machine. Component approvals are not equivalent to certification of the finished unit. If your insurer, inspector or purchasing standard requires a specific listing, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask before ordering and we will request the certificate from the manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eFreight only, lower 48\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping priced at checkout based on your address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e680 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, plan for a forklift, loading dock or terminal pickup. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the pallet, crating, tank, gauges and starter box. Record any damage on the bill of lading \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ein front of the driver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before accepting delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty covering parts and labor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Purchasing the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-3 maintenance kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with the compressor and registering the machine extends coverage under Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year \"No Bull\" Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including on-site service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe maintenance kit must be purchased \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eat the time of the original order\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and cannot be added later.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45964657918005,"sku":"253D80VCB23M","price":4504.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/253D80VCB23M__61890.1684437985.1280.1280_4c6ddca7-b7ea-49b0-8af9-4f462e772b9b.webp?v=1788357515"},{"product_id":"quincy-air-compressor-453d80vcb46m-qt-max-80-gallon-two-stage","title":"Quincy Air Compressor 453D80VCB46M QT Max 80 Gallon Two Stage","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 5 HP air compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is built for shops that need to pair reliable compressed air with a refrigerated dryer. Its factory-installed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e removes much of the moisture before the air reaches your dryer, reducing the amount of bulk condensate the dryer has to handle. The result is a better-prepared air supply for downstream drying equipment. The compressor combines a splash-lubricated cast iron two-stage pump, an 80-gallon vertical ASME receiver, and a factory magnetic starter. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRequires 460V 3-Phase power.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe aftercooler is the key advantage for moisture-sensitive compressed-air systems. Hot, moisture-laden air leaving the pump is cooled before entering the receiver, allowing much of that moisture to condense at the tank rather than farther down the air lines. It does not replace a refrigerated dryer, but it \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ereduces the bulk moisture load\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reaching it so the dryer can focus on removing the remaining water vapor. A separate finned intercooler between the pump's two compression stages also helps control operating temperature by cooling the air before the second stage. Combined with the pump's slow rotation, cast iron construction, and low-oil shutdown, these features support the manufacturer's stated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000+ hour pump life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration is well suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eprofessional shops already running a refrigerated dryer or planning to install one\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, particularly where moisture control directly affects the finished work. Paint and finishing operations, plasma cutting, blast cabinets, automotive service facilities, and plants with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V three-phase distribution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e can all benefit from having moisture reduced before air reaches the rest of the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Things to Confirm Before Ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The title and specifications list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e453D80VCB46M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the description and page URL list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e253D80VCB46M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Send us the model number on your paperwork so we can confirm the exact build and voltage with the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eTank drain:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published details conflict. The feature list and detailed specifications indicate an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic automatic drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while another field says no drain is fitted. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIf the drain is important to your application, ask us to confirm it in writing before ordering.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage, Space \u0026amp; Access\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis model requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. If your facility uses a different three-phase voltage, contact us for the correct model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 37\" × 24\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 74\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 680 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBreaker:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not specified; consult a certified electrician\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eConfirm the electrical supply, breaker requirements, ceiling clearance, delivery access and floor capacity before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy the Aftercooler Matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompressed air leaves the pump hot and moisture-laden. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduces the temperature before air enters the receiver, causing much of the moisture to condense in the tank instead of downstream piping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis helps reduce water and corrosion and allows a refrigerated dryer to work more efficiently. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAn aftercooler does not replace a refrigerated dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when genuinely dry air is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCast Iron, Cooled Twice\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efinned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e cools the air between compression stages, improving efficiency and reducing discharge temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe slow-speed cast-iron pump features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAluminum heads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-piece connecting rods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eManufacturer-rated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000+ hour pump life\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eShops using or planning to add a refrigerated dryer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePaint, powder coating and finishing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePlants with 460V three-phase power\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePlasma cutting and blast cabinets\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCast-iron two-stage pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e5 HP motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e80-gallon vertical ASME receiver\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFinned intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir-cooled aftercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass and gauges\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir delivery\u003c\/td\u003e\n\u003ctd\u003e17.2 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure\u003c\/td\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump\u003c\/td\u003e\n\u003ctd\u003eTwo-stage, splash lubricated, cast iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAir treatment\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAftercooler\u003c\/td\u003e\n\u003ctd\u003eAir-cooled, fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntercooler\u003c\/td\u003e\n\u003ctd\u003eFinned, between stages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir dryer\u003c\/td\u003e\n\u003ctd\u003eNot fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePower, Tank \u0026amp; Size\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e460V 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver\u003c\/td\u003e\n\u003ctd\u003e80 gallon, vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank outlet\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFootprint\u003c\/td\u003e\n\u003ctd\u003e37\" by 24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e74\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e680 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur data supports an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e on the electrical components, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUS manufacture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e as stated in the feature list.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe do not claim a third-party safety listing for the complete machine assembly. Component approvals are separate from certification of the finished unit. If your plant standards or insurer require a specific listing, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask before ordering and we will confirm it with the manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFreight shipping is available throughout the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the rate calculated at checkout based on your address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e680 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, unloading requires a forklift, loading dock or terminal pickup. Residential delivery carries an additional fee, and terminal pickup may be the simpler option.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the crate, tank, gauges and starter enclosure, and record any damage on the bill of lading in front of the driver.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty covering parts and labor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year \"No Bull\" Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may extend coverage when the required maintenance kit is purchased with the compressor and the unit is registered promptly. Confirm the exact requirements for this model \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, as the extension cannot be added later.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45964686426165,"sku":"453D80VCB46M","price":4504.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/253D80VCB46M__24585.1679853597.1280.1280.png?v=1788358078"},{"product_id":"quincy-air-compressor-453ds80hcb20-qt-pro-5-hp-80-gallon-two-stage-208v-3-phase","title":"Quincy Air Compressor 453DS80HCB20 QT Pro 5 HP 80 Gallon Two Stage 208V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 5 HP air compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is built for shops that need to pair reliable compressed air with a refrigerated dryer. Its factory-installed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e removes much of the moisture before the air reaches your dryer, reducing the amount of bulk condensate the dryer has to handle. The result is a better-prepared air supply for downstream drying equipment. The compressor combines a splash-lubricated cast iron two-stage pump, an 80-gallon vertical ASME receiver, and a factory magnetic starter. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRequires 460V 3-Phase power.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe aftercooler is the key advantage for moisture-sensitive compressed-air systems. Hot, moisture-laden air leaving the pump is cooled before entering the receiver, allowing much of that moisture to condense at the tank rather than farther down the air lines. It does not replace a refrigerated dryer, but it \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ereduces the bulk moisture load\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reaching it so the dryer can focus on removing the remaining water vapor. A separate finned intercooler between the pump's two compression stages also helps control operating temperature by cooling the air before the second stage. Combined with the pump's slow rotation, cast iron construction, and low-oil shutdown, these features support the manufacturer's stated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000+ hour pump life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration is well suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eprofessional shops already running a refrigerated dryer or planning to install one\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, particularly where moisture control directly affects the finished work. Paint and finishing operations, plasma cutting, blast cabinets, automotive service facilities, and plants with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V three-phase distribution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e can all benefit from having moisture reduced before air reaches the rest of the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Model Codes to Confirm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur records list this unit under two codes: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e453DS80HCB20\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the product title and specifications, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e253DS80HCB20\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the manufacturer copy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf you are matching an existing machine or ordering parts, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us to confirm the correct model code in writing before ordering.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose the Horizontal Tank?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe horizontal \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e keeps the pump, belt guard, oil sight glass and drain closer to working height, making routine maintenance easier. It also suits installations where ceiling height is limited.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approximately 70\" × 23\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 660 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3\/4\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTank:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 80-gallon horizontal, coded receiver\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tradeoff is floor space. If floor area is the main limitation, consider the vertical version instead. Install the compressor on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eflat, solid, level surface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e; leveling and site preparation are the customer's responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Stage Cast-Iron Pump\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT-5 splash-lubricated, belt-driven pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e uses a cast-iron design with an aluminum head and high-efficiency finned intercooler. Air is compressed in two stages, with cooling between them to improve efficiency and control operating temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutput:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 17.2 CFM at 175 PSI\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-piece connecting rods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOversized oil reservoir\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSlow-speed operation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor \u0026amp; Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eODP slow-speed motor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e drives the pump, helping reduce heat, wear and operating noise.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFactory protection includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic condensate drain\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnclosed belt guard\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specified electrical supply is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5 HP, 208V, 3-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Breaker and conductor sizing depend on the installation, so have a qualified electrician size the circuit to local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLow-ceiling workshops and service bays\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial and industrial 208V three-phase facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShops running multiple air tools\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOwners who perform their own routine maintenance\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eQT-5 two-stage cast-iron pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eODP slow-speed motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFinned intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-piece connecting rods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOversized oil reservoir\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic condensate drain\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnclosed belt guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e80-gallon horizontal coded receiver\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRelief valves and 3\/4\" outlet\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e208 Volt AC, 3-Phase — not field-convertible to another voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003eODP, slow speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMagnetic starter\u003c\/th\u003e\n\u003ctd\u003eFactory mounted, with thermal overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBreaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePump and output\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eQT-5 two-stage, belt drive, splash lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003eCast iron with aluminium head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003e17.2 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eHigh-efficiency finned intercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eLow-oil shutdown; automatic condensate drain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTank and dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e80-gallon, horizontal, coded, with relief valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall\u003c\/th\u003e\n\u003ctd\u003e70\" long × 23\" wide × 47\" high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e660 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecoded pressure vessel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and our data lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e recognition for the electrical components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese are not the same as a third-party safety listing for the complete assembled machine. If your insurer or local inspector requires a specific listing, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us before ordering so we can confirm the requirement with the manufacturer.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Receiving\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor ships by palletized freight throughout the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout based on your address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan for unloading in advance. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eloading dock, forklift or pallet jack\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is recommended. If you do not have suitable equipment, terminal pickup is an option. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the pallet and crate, photograph any damage, and record it on the bill of lading in front of the driver. Damage discovered after a clean signature can be difficult to claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe unit includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and may qualify for Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year \"No Bull\" Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e under the manufacturer's terms. The extended coverage is conditional, so review the warranty terms and confirm what applies to this model before relying on the longer period.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45966429356085,"sku":"2020040799","price":3577.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/253DS80HCB20__62436.1685018263.1280.1280.png?v=1788393195"},{"product_id":"quincy-air-compressor-453ds80hcb23-qt-pro-5-hp-80-gallon-two-stage-230v-3-phase","title":"Quincy Air Compressor 453DS80HCB23 QT Pro 5 HP 80 Gallon Two Stage 230V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 5 HP air compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines an 80-gallon horizontal receiver with a two-stage pump for shops that need substantial air capacity without the height of an upright tank. At approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e47\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, it fits beneath low ceilings, mezzanines, and door tracks where a vertical compressor may not. The splash-lubricated cast iron pump delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e17.2 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the factory-installed magnetic starter and low-oil shutdown add protection for demanding operation. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRequires 230V 3-Phase power.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe horizontal configuration puts the compressor's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esight glass, belt guard, and drain within easier reach\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making routine inspections and maintenance more convenient. The pump uses two-stage compression with a high-efficiency finned intercooler between stages, cooling the air before it enters the second stage and helping the compressor maintain its 175 PSI working pressure. An \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoversized oil reservoir\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps control oil temperature during extended use, while the slow-speed ODP motor reduces heat and wear. The two-piece connecting rods and stated oil carryover of less than 5 PPM further support long-term operation and cleaner compressed air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis model is a good fit for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecommercial and light-industrial shops with 230V three-phase service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, especially where ceiling height is more limited than floor space. It works well for continuous production environments running multiple air tools or equipment throughout the day. The horizontal layout also makes sense for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eowners who perform their own routine servicing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, since key inspection and maintenance points remain accessible without reaching overhead.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCertification, Stated Plainly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecoded pressure vessel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and our data lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e recognition for the electrical components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese are not the same as a third-party safety listing for the complete assembled machine. If your insurer or local inspector requires a specific listing, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us before ordering so we can confirm the requirement with the manufacturer.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping \u0026amp; Receiving\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor ships by palletized freight throughout the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout based on your address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan for unloading in advance. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eloading dock, forklift or pallet jack\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is recommended. If you do not have suitable equipment, terminal pickup is an option. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the pallet and crate, photograph any damage, and record it on the bill of lading in front of the driver. Damage discovered after a clean signature can be difficult to claim.\u003c\/span\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e230 Volt AC, 3-Phase — model-specific, not field-convertible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003eODP, slow speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e\n\u003ctd\u003eMagnetic, factory mounted, thermal overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBreaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePump and air\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eQT-5 two-stage, belt drive, splash lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003e17.2 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOil carryover\u003c\/th\u003e\n\u003ctd\u003eUnder 5 PPM, per the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnecting rods\u003c\/th\u003e\n\u003ctd\u003eTwo-piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eHigh-efficiency finned intercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReceiver and size\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003e80-gallon, horizontal, coded, relief valves fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrain\u003c\/th\u003e\n\u003ctd\u003eAutomatic condensate drain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall\u003c\/th\u003e\n\u003ctd\u003e70\" × 23\" × 47\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e660 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur data lists a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecoded pressure-vessel receiver with relief valves\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA recognition\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for the electrical components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese are not equivalent to a third-party safety listing for the complete machine as installed. If your insurer, fleet policy or local inspector requires a specific listing, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us before ordering so we can confirm the requirement with the manufacturer.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Receiving\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epalletized freight throughout the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout for your address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan for unloading in advance. You will need a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eloading dock, forklift or pallet jack with level ground\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. If those aren't available, terminal pickup is an option. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Photograph the pallet and crate and record any damage on the bill of lading while the driver is present. Damage discovered after a clean signature can be difficult to claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and extends to Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year \"No Bull\" Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e under the manufacturer's terms. The extended coverage is conditional, so review the warranty handbook and confirm the requirements for this model before relying on the additional coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45966445346869,"sku":"2020040801","price":3577.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/253DS80HCB23__94310.1685018254.1280.1280.png?v=1788393792"},{"product_id":"quincy-air-compressor-453ds80hcb46-qt-pro-5-hp-80-gallon-two-stage-460v-3-phase","title":"Quincy Air Compressor 453DS80HCB46 QT Pro 5 HP 80 Gallon Two Stage 460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 5 HP air compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines a horizontal 80-gallon receiver with a two-stage industrial pump for facilities that have the right three-phase power but limited ceiling height. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V 3-Phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e motor draws less current than lower-voltage versions of the same 5 HP package, making this configuration well suited to buildings with higher-voltage distribution and longer electrical runs. The pump delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e17.2 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while a factory-mounted magnetic starter with thermal overload and low-oil shutdown provides built-in protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe horizontal receiver keeps the machine to approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e47\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e while putting the drain, oil sight glass, and belt guard within easier reach. The pump uses cast iron construction with an aluminum head, splash lubrication, and two-stage compression with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between stages. This cooling helps manage operating temperatures and supports the 175 PSI working pressure. An oversized oil reservoir helps control oil temperature during continuous operation, while the slow-speed ODP motor reduces heat and component wear. Automatic condensate draining also removes the need for routine manual tank draining.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindustrial buildings with 460V three-phase service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, particularly facilities where lower current is advantageous for longer cable runs. The horizontal tank makes it a practical choice for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-ceiling plant rooms, bays, and workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where an upright 80-gallon compressor will not fit. It is also suited to production environments, fabrication shops, blasting applications, and other operations requiring continuous compressed air from multiple tools or workstations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Codes, One Machine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur records list this unit as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e453DS80HCB46\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the title and specifications, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e253DS80HCB46\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the manufacturer copy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf you are matching an installed machine or ordering parts, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask us to confirm the correct model code before purchasing.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe 460V build uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5 HP, 460V, 3-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e power. Breaker, conductor and starter sizing depend on the installation, run length, ambient conditions and local code. Have a qualified electrician size the circuit for your facility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efactory-mounted magnetic starter with thermal overload\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHorizontal 80-Gallon Receiver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe horizontal tank keeps the overall height to approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e47\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a footprint of about \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e70\" × 23\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. This makes it a good option for low-clearance areas while providing easier access to the drain, sight glass and belt guard.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTank:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 80 gallons, horizontal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approx. 47\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Approx. 70\" × 23\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 660 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3\/4\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInstall the compressor on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eflat, solid and level surface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Site preparation is the buyer's responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Stage QT-5 Pump\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebelt-driven, splash-lubricated QT-5 pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e uses a cast-iron design with an aluminum head and high-efficiency finned intercooler. Two-stage compression and intercooling help improve efficiency and control operating temperature at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutput:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 17.2 CFM at 175 PSI\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOil carryover:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u0026lt;5 PPM\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-piece connecting rods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOversized oil reservoir\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eODP slow-speed motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe machine includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic condensate drain\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnclosed belt guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAutomatic draining helps manage receiver condensate, while low-oil shutdown protects the pump from lubrication problems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eIndustrial facilities with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-ceiling plant rooms and service bays\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLong electrical runs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProduction, fabrication and blasting shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContinuous multi-tool applications\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eQT-5 two-stage cast-iron pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eODP slow-speed motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFinned intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-piece connecting rods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOversized oil reservoir\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic condensate drain\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnclosed belt guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eHorizontal \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon coded receiver\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRelief valves\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e3\/4\" outlet\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e460 Volt AC, 3-Phase — wound for this voltage only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003eODP, slow speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e\n\u003ctd\u003eMagnetic, factory mounted, with thermal overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBreaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePump\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eQT-5 two-stage, belt drive, splash lubricated, cast iron with aluminium head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003e17.2 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOil carryover\u003c\/th\u003e\n\u003ctd\u003eUnder 5 PPM, per the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eLow-oil shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReceiver and dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003e80-gallon, horizontal, coded, with relief valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrain\u003c\/th\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall\u003c\/th\u003e\n\u003ctd\u003e70\" × 23\" × 47\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e660 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver is listed as a coded pressure vessel built to American standards, with relief valves fitted. The electrical components are listed with UL and CSA recognition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese do \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e mean the complete assembled machine has a third-party safety listing. If your insurer, inspector, or facility standard requires one, ask us to confirm the applicable documentation before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Receiving\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips palletized freight throughout the lower 48 states. Shipping is calculated at checkout based on your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan unloading before ordering. Have a loading dock, forklift, or pallet jack ready on firm, level ground. If unavailable, terminal pickup may be an option. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Photograph the pallet\/crate and record any damage on the bill of lading with the driver present. Damage discovered after a clean signature may be difficult to claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe machine includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-Year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and may qualify for Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, subject to manufacturer requirements. Review the warranty terms and confirm the conditions for this model before relying on the extended coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45966495940661,"sku":"2020040802","price":3577.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/253DS80HCB46-1__68209.1685018242.1280.1280.jpg?v=1788396500"},{"product_id":"quincy-air-compressor-453ds80vcb23-qt-pro-5-hp-80-gallon-two-stage-230v-3-phase","title":"Quincy Air Compressor 453DS80VCB23 QT Pro 5 HP 80 Gallon Two Stage 230V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 5 HP air compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines a horizontal 80-gallon receiver with a two-stage industrial pump for facilities that have the right three-phase power but limited ceiling height. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V 3-Phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e motor draws less current than lower-voltage versions of the same 5 HP package, making this configuration well suited to buildings with higher-voltage distribution and longer electrical runs. The pump delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e17.2 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while a factory-mounted magnetic starter with thermal overload and low-oil shutdown provides built-in protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe horizontal receiver keeps the machine to approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e47\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e while putting the drain, oil sight glass, and belt guard within easier reach. The pump uses cast iron construction with an aluminum head, splash lubrication, and two-stage compression with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between stages. This cooling helps manage operating temperatures and supports the 175 PSI working pressure. An oversized oil reservoir helps control oil temperature during continuous operation, while the slow-speed ODP motor reduces heat and component wear. Automatic condensate draining also removes the need for routine manual tank draining.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindustrial buildings with 460V three-phase service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, particularly facilities where lower current is advantageous for longer cable runs. The horizontal tank makes it a practical choice for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-ceiling plant rooms, bays, and workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where an upright 80-gallon compressor will not fit. It is also suited to production environments, fabrication shops, blasting applications, and other operations requiring continuous compressed air from multiple tools or workstations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Codes for One Machine\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur records list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e453DS80VCB23\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the product title\/specifications and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e253DS80VCB23\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the manufacturer copy. Both refer to this compressor. If you are matching an installed unit or ordering parts, ask us to confirm the correct code before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for Continuous Duty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eContinuous operation depends on the complete system working together: an aluminum head, balanced cast-iron flywheel, finned intercooler, oversized oil reservoir, slow-speed ODP motor, industrial bearings, and cast-iron cylinders.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese features help manage heat, maintain oil performance, and reduce wear during extended operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Stage Compression\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAir is compressed in two stages, with cooling between them. The finned intercooler reduces heat before the second stage, supporting reliable operation at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and helping limit heat-related valve and carbon buildup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished output is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e17.2 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with oil carryover under \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5 PPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVertical 80-Gallon Receiver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe vertical receiver measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e at the floor and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e74\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e high. It suits installations where floor space is limited but ceiling clearance is available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eMeasure for overhead clearance and service access before delivery. At \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e680 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the compressor requires a flat, solid, level surface.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3\/4\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e tank outlet is provided, but no aftercooler or air dryer is included. Filtration, drying, regulation, and shop piping must be designed separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFactory-Fitted Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIncluded from the factory:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic tank drain\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnclosed belt guard\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor electrical installation, provide your electrician with the actual load: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5 HP, 230V, 3-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Conductor and breaker sizing depend on run length, installation conditions, and local code. Manufacturer current data is available if needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eShops requiring extended or continuous air use\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e230V 3-phase commercial and industrial facilities\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstallations with limited floor space and adequate ceiling height\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpray and instrument applications where low oil carryover matters\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete factory-built compressor with two-stage splash-lubricated cast-iron pump, aluminum head, slow-speed ODP motor, magnetic starter with thermal overload, finned intercooler, balanced cast-iron flywheel, oversized oil reservoir, sight glass, belt guard, low-oil shutdown, automatic drain, and vertical \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon coded receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with relief valves and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3\/4\" outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e aftercooler, air dryer, filters, regulators, or shop piping.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSupply and motor\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e230 Volt AC, 3-Phase — model-specific, not convertible on site\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003eODP, slow speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e\n\u003ctd\u003eMagnetic, factory mounted, with thermal overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBreaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePump\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive, splash lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterials\u003c\/th\u003e\n\u003ctd\u003eCast iron cylinders, aluminium head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003e17.2 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOil carryover\u003c\/th\u003e\n\u003ctd\u003eUnder 5 PPM, per the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTank and size\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e80-gallon, vertical, coded, relief valves fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrain\u003c\/th\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall\u003c\/th\u003e\n\u003ctd\u003e37\" × 24\" × 74\" high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e680 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listing supports two claims: a coded pressure vessel built to American standards with relief valves, and UL\/CSA recognition for the electrical components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese are \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e the same as a third-party safety listing for the complete assembled machine. If your insurer, inspector, or facility standard requires that specific listing, confirm the required documentation with us before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Receiving\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips palletized freight throughout the lower 48 states, with shipping calculated at checkout based on your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan unloading in advance. Have a loading dock, forklift, or pallet jack ready on firm, level ground. If unavailable, terminal pickup may be an option. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Photograph the pallet and crate, and record any damage on the bill of lading with the driver present. Damage discovered after a clean signature may be difficult to claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe machine includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-Year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and may qualify for Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, subject to manufacturer requirements. Review the warranty handbook and confirm the conditions for this model before relying on the extended coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45966519828533,"sku":"453DS80VCB23","price":3577.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/253DS80VCB23__51079.1685018230.1280.1280.webp?v=1788397555"},{"product_id":"quincy-air-compressor-453ds80vcb46-qt-pro-5-hp-80-gallon-two-stage-460v-3-phase","title":"Quincy Air Compressor 453DS80VCB46 QT Pro 5 HP 80 Gallon Two Stage 460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 5 HP air compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines a horizontal 80-gallon receiver with a two-stage industrial pump for facilities that have the right three-phase power but limited ceiling height. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V 3-Phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e motor draws less current than lower-voltage versions of the same 5 HP package, making this configuration well suited to buildings with higher-voltage distribution and longer electrical runs. The pump delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e17.2 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while a factory-mounted magnetic starter with thermal overload and low-oil shutdown provides built-in protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe horizontal receiver keeps the machine to approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e47\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e while putting the drain, oil sight glass, and belt guard within easier reach. The pump uses cast iron construction with an aluminum head, splash lubrication, and two-stage compression with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between stages. This cooling helps manage operating temperatures and supports the 175 PSI working pressure. An oversized oil reservoir helps control oil temperature during continuous operation, while the slow-speed ODP motor reduces heat and component wear. Automatic condensate draining also removes the need for routine manual tank draining.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindustrial buildings with 460V three-phase service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, particularly facilities where lower current is advantageous for longer cable runs. The horizontal tank makes it a practical choice for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-ceiling plant rooms, bays, and workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where an upright 80-gallon compressor will not fit. It is also suited to production environments, fabrication shops, blasting applications, and other operations requiring continuous compressed air from multiple tools or workstations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCertification, Stated Plainly\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listing supports two claims: a coded pressure vessel built to American standards with relief valves, and UL\/CSA recognition for the electrical components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese are \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e the same as a third-party safety listing for the complete assembled machine. If your insurer, inspector, or facility standard requires that specific listing, confirm the required documentation with us before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShipping \u0026amp; Receiving\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips palletized freight throughout the lower 48 states, with shipping calculated at checkout based on your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan unloading in advance. Have a loading dock, forklift, or pallet jack ready on firm, level ground. If unavailable, terminal pickup may be an option. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Photograph the pallet and crate, and record any damage on the bill of lading with the driver present. Damage discovered after a clean signature may be difficult to claim.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSupply\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e460 Volt AC, 3-Phase — wound for this voltage only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003eCapacitor start, heavy-duty industrial, built-in thermal overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent\u003c\/th\u003e\n\u003ctd\u003eThe lowest of this family, per our specification data. Ask us for the figure in writing; circuit sizing belongs to your electrician.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePump\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive, splash lubricated, cast iron with aluminium head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eValves\u003c\/th\u003e\n\u003ctd\u003eStainless steel reed, controlled lift\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStated pump life\u003c\/th\u003e\n\u003ctd\u003eIn excess of 50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003eRecorded in our data as 17.2 cubic feet per minute. Ask us to confirm it in writing before designing an air system around it.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eHigh-efficiency finned tube intercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReceiver and dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003e80-gallon, vertical, with pressure relief\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall\u003c\/th\u003e\n\u003ctd\u003e37\" × 24\" × 74\" high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e680 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe listing states UL and CSA approval for the electrical components, and the receiver is listed as a coded pressure vessel built to American standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese are \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e equivalent to a third-party safety listing for the complete assembled machine. If your insurer, inspector, or facility standard requires that specific listing, confirm the documentation with us before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Receiving\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips palletized freight throughout the lower 48 states, with shipping calculated at checkout based on your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eArrange unloading before ordering. Have a loading dock, forklift, or pallet jack ready on firm, level ground. If unavailable, terminal pickup may be an option. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Photograph the pallet and crate, and record any damage on the bill of lading with the driver present. Damage discovered after a clean signature may be difficult to claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe machine includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-Year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and extends to Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when the required maintenance kit is purchased with the compressor and the unit is registered. The extended coverage includes on-site labor and service for covered defects in materials and workmanship.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45966576844853,"sku":"453DS80VCB46","price":3577.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/253DS80VCB46__98706.1685018220.1280.1280.webp?v=1788398259"},{"product_id":"quincy-air-compressor-471cs80hcb-qt-pro-7-5-hp-80-gallon-two-stage-230v-1-phase","title":"Quincy Air Compressor 471CS80HCB QT Pro 7.5 HP 80 Gallon Two Stage 230V 1 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 7.5 HP air compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is built for shops that need high-capacity compressed air without the height of a vertical receiver. Its horizontal \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon tank\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e keeps the overall machine to approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e47\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it suitable for low-ceiling workshops, mezzanines, and bays with overhead door tracks. A two-cylinder cast iron QT-7.5 belt-drive pump operates at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a 100% duty rating, while the 7.5 HP industrial motor runs on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V 1-Phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAn 80 Amp breaker is specified for this configuration.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the key feature for continuous-demand applications. The compressor is designed to keep working without a required rest period, supported by cast iron cylinders, industrial-class bearings, a balanced crankshaft, and a large cast iron flywheel that helps move cooling air across the pump. A finned tube intercooler cools the air between compression stages, helping the second stage compress cooler, denser air while reducing heat and carbon buildup. Stainless steel reed valves, graphite gaskets, two-piece connecting rods, and a slower-running motor further support operation under sustained loads. This model does not include a low-oil shutdown, so \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eregularly checking the oil sight glass is important\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis compressor is a practical choice for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-ceiling commercial shops, single-phase facilities, and operations with continuous air demand\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It can suit applications such as spraying, blasting, production air, and busy service environments where the compressor may need to run for extended periods. The horizontal layout is especially useful when floor space is available but vertical clearance is limited, while the 230V single-phase motor avoids the need for a three-phase electrical installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConfirm Air Delivery Before Ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis page does not provide a CFM rating, and the supplied descriptions conflict on horsepower and air delivery. Since CFM determines system sizing, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etell us your application and working pressure before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e so we can confirm the manufacturer's rated delivery in writing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis build also \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edoes not include low-oil shutdown\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The oil sight glass is provided, so include regular oil checks in your maintenance schedule.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis horizontal compressor measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e70\" L × 23\" W × 47\" H\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it a good fit for low-ceiling shops, under shelving, or along a wall. The belt guard, sight glass, drain, and outlet remain accessible at standing height.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tradeoff is floor space. A vertical 80-gallon model uses less floor area but requires more headroom.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e740 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, plan the delivery route, final location, and floor capacity in advance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical requirements are listed as an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80A breaker on 230V single-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A qualified electrician should confirm conductor sizing and disconnect requirements based on the actual installation, cable length, ambient conditions, and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e100% Duty Cycle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e means the compressor is designed for continuous operation without a required off period.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThat makes it suitable for steady-demand applications such as spraying, blasting, production air, and busy service bays.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCooling \u0026amp; Pump Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two-stage pump uses a high-efficiency finned-tube intercooler between stages to reduce compression heat and support efficient second-stage operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe cast-iron cylinders, industrial bearings, balanced crankshaft, large cast-iron flywheel, stainless-steel reed valves, graphite gaskets, and two-piece connecting rods are built for durability under extended operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e7.5 HP capacitor-start industrial motor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e includes thermal overload protection and operates at a lower speed than typical general-purpose motors, supporting cooler and quieter operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eLow-ceiling workshops\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e7.5 HP single-phase installations\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eContinuous-demand spraying, blasting, and production\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eUnder mezzanines, shelving, or along shop walls\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete assembled compressor with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT-7.5 two-cylinder cast-iron belt-drive pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, 7.5 HP industrial motor with thermal overload, balanced cast-iron flywheel, finned-tube intercooler, magnetic starter, gauges, and horizontal \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor \u0026amp; Pump\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e7.5 HP, capacitor start, thermal overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V 1-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaker\u003c\/td\u003e\n\u003ctd\u003e80 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump\u003c\/td\u003e\n\u003ctd\u003eTwo-stage, two-cylinder cast iron, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLubrication\u003c\/td\u003e\n\u003ctd\u003eSplash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure\u003c\/td\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle\u003c\/td\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTank \u0026amp; Dimensions\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver\u003c\/td\u003e\n\u003ctd\u003e80 gallon, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank outlet\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e70\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e23\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e47\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e740 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAftercooler\u003c\/td\u003e\n\u003ctd\u003eNot fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe data lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA approval for the electrical components\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME certification for the receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and describes the machine as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuilt in the U.S.A.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e We make no additional certification claims.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese do \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e constitute a third-party safety listing for the complete assembled machine. If your insurer, inspector, or corporate standard requires that specific listing, ask us before ordering so we can confirm the available documentation with the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips freight throughout the lower 48, with shipping calculated at checkout based on your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e740 lb and 70\" long\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, arrange a forklift or loading dock, or consider terminal pickup. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the crate, tank, gauges, and starter enclosure. Photograph and record any damage on the bill of lading while the driver is present. A clean signed receipt can make freight damage claims difficult.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-Year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies. Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requires the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-3 maintenance kit to be purchased with the compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and the unit to be registered with Quincy. The extension includes on-site labor and service and cannot be added later.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45966648115253,"sku":"2020040815","price":4446.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/o-Quincy-QT-Max-Horizontal_684px_1.webp?v=1788398769"},{"product_id":"quincy-air-compressor-471cs80vcb-7-5-hp-80-gallon-two-stage-vertical","title":"Quincy Air Compressor 471CS80VCB 7.5 HP 80 Gallon Two Stage Vertical","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 7.5 HP air compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers the capacity of a full-size two-stage industrial compressor while running on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Its cast iron QT-7.5 belt-drive pump is paired with a vertical \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and rated for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it a practical alternative for facilities that need 7.5 HP but do not have three-phase service. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy specifies an 80 Amp breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so confirm your electrical panel can support the required circuit before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage compression design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a high-efficiency finned tube intercooler between stages. Cooling the air before the second stage helps reduce operating temperatures while allowing the compressor to reach its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e working pressure. The cast iron pump uses an aluminum head, stainless steel reed valves, industrial-class bearings, graphite gaskets, and two-piece connecting rods for durability and serviceability. A balanced cast iron flywheel helps smooth pump operation while its fan design moves cooling air across the pump and intercooler. The industrial motor includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecapacitor start and thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, supporting the compressor during extended operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration is ideal for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindependent automotive shops, body and paint operations, restoration garages, fabrication shops, and serious home workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need sustained compressed-air capacity but only have single-phase power available. The vertical receiver occupies roughly \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\" of floor space\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it a good fit where floor area is limited, although the approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e74\" overall height\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requires adequate ceiling clearance. It is especially useful for customers outgrowing smaller single-stage compressors who want two-stage performance without installing three-phase service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe 80 Amp Circuit Is the Real Decision\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy specifies an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80A breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this compressor. That is a substantial single-phase load, so confirm with a qualified electrician that your panel can support it before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSingle-phase motors require more current than comparable three-phase motors, which means greater demand on your panel and wiring. The compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efactory-mounted magnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with contactor and overload protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMade in the USA, Built for Service\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe manufacturer states this compressor is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuilt in the USA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It uses a cast-iron \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT-7.5 two-stage belt-drive pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with an aluminum head, industrial-class bearings, graphite gaskets, stainless-steel reed valves, and two-piece connecting rods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe stainless-steel valves resist corrosion and controlled lift reduces wear. The two-piece rods also simplify bearing service without requiring complete bottom-end disassembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Vertical?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe vertical receiver uses approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of floor space, making it a strong choice when floor area is limited.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tradeoff is height: approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e74\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Check clearance for lighting, ductwork, sprinklers, mezzanines, and roll-up doors, while allowing room for maintenance access.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e720 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, install it on a flat, solid, level surface and secure it properly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Stage Cooling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump compresses air in two stages, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned-tube intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between them. Cooling the air before the second stage helps control compression heat and supports reliable operation at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe balanced cast-iron flywheel smooths pump operation while its fan design helps move cooling air across the pump and intercooler.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe heavy-duty industrial motor features \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecapacitor start and built-in thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and operates at a lower speed than typical light-duty compressor motors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eShops without three-phase power\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBody, paint, and restoration work\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSerious private and collector workshops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSmall fabrication shops with limited floor space\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUsers outgrowing single-stage compressors\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete assembled compressor with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT-7.5 two-stage cast-iron pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, intercooler, belt guard, heavy-duty motor with capacitor start and thermal overload, magnetic starter, gauges, oil sight glass, and vertical \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e7.5 HP, 230V, single phase, capacitor start, thermal overload, magnetic starter fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCircuit\u003c\/th\u003e\n\u003ctd\u003e80 Amp breaker specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eQT-7.5 two-stage cast iron with aluminum head, belt drive, splash lubricated, two-piece rods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003e80-gallon vertical receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFootprint\u003c\/th\u003e\n\u003ctd\u003e37\" × 24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall height\u003c\/th\u003e\n\u003ctd\u003e74\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e720 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003eNot published here — ask us and we will confirm it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe product information lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA approvals for the electrical components\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME certification for the pressure vessel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These apply to the components and tank respectively and do not certify your installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your insurer or local authority requires a specific listing or inspection for the receiver, verify the requirement against the machine's data plate before ordering. We can provide the manufacturer's available documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-Year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies and may extend to Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e under the manufacturer's program and registration requirements. We will confirm the exact conditions for this model before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFreight \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips palletized freight throughout the lower 48, with shipping calculated at checkout. At approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e720 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, plan for a forklift or pallet jack at delivery. Terminal pickup with a suitable trailer may be used when site unloading equipment is unavailable. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInspect before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the tank, pump, belt guard, motor, and pallet. Photograph any damage and record it on the bill of lading with the driver present. A clean signed receipt can make freight damage claims difficult.\u003c\/span\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45969724702773,"sku":"2020040716","price":3499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/271CS80VCB23__06835.1679938335.1280.1280.png?v=1788465656"},{"product_id":"quincy-air-compressor-471cs80vcbm-qt-max-7-5-hp-80-gallon-two-stage-230v-1-phase","title":"Quincy Air Compressor 471CS80VCBM QT Max 7.5 HP 80 Gallon Two Stage 230V 1 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT Pro 7.5 HP air compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers the capacity of a full-size two-stage industrial compressor while running on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Its cast iron QT-7.5 belt-drive pump is paired with a vertical \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and rated for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it a practical alternative for facilities that need 7.5 HP but do not have three-phase service. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy specifies an 80 Amp breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so confirm your electrical panel can support the required circuit before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage compression design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a high-efficiency finned tube intercooler between stages. Cooling the air before the second stage helps reduce operating temperatures while allowing the compressor to reach its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e working pressure. The cast iron pump uses an aluminum head, stainless steel reed valves, industrial-class bearings, graphite gaskets, and two-piece connecting rods for durability and serviceability. A balanced cast iron flywheel helps smooth pump operation while its fan design moves cooling air across the pump and intercooler. The industrial motor includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecapacitor start and thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, supporting the compressor during extended operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration is ideal for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eindependent automotive shops, body and paint operations, restoration garages, fabrication shops, and serious home workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need sustained compressed-air capacity but only have single-phase power available. The vertical receiver occupies roughly \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\" of floor space\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it a good fit where floor area is limited, although the approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e74\" overall height\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requires adequate ceiling clearance. It is especially useful for customers outgrowing smaller single-stage compressors who want two-stage performance without installing three-phase service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Things to Confirm Before Ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAutomatic tank drain:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The records conflict. The feature list and detailed specifications indicate an automatic\/electronic drain, while another field says no drain is fitted. If this feature matters, ask us to confirm it with the manufacturer in writing before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAir delivery:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No CFM rating is published because the catalogue and inherited listing contain conflicting figures. Since CFM determines system sizing, tell us your application and working pressure so we can confirm the manufacturer's rated delivery before you order.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe vertical compressor measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\" × 74\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e720 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Check the installation area, doorways, delivery route, ceiling clearance, and floor capacity before delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe unit requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. No breaker size is specified for this build, so have a qualified electrician size the circuit from the motor data plate based on conductor length, ambient conditions, local code, and existing panel load.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSite preparation, electrical installation, and drain routing are the buyer's responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy the Aftercooler Matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduces discharge temperature before compressed air enters the receiver. This encourages moisture to condense at the tank rather than downstream in your piping and hoses, helping reduce water reaching filters, dryers, and air tools.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efinned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e serves a different purpose: it cools air between the two compression stages, reducing heat before the second stage and supporting efficient operation at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Stage Cast-Iron Pump\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe slow-speed, two-stage pump uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron cylinders\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, an aluminum head, and a high-efficiency intercooler. Two-stage compression supports the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e working pressure while controlling heat.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAdditional features include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e50,000-hour rated pump life\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-piece connecting rods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOversized oil reservoir\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSlow-speed operation for reduced heat and vibration\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBody and paint shops on 230V single-phase power\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndependent automotive service bays\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFabrication and welding shops\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSerious home and hobby workshops\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete assembled compressor with pump, motor, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon vertical receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, magnetic starter, pressure gauges, finned intercooler, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePump \u0026amp; Output\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e7.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump type\u003c\/td\u003e\n\u003ctd\u003eTwo-stage, belt drive, splash lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump material\u003c\/td\u003e\n\u003ctd\u003eCast iron with aluminium head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure\u003c\/td\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAftercooler\u003c\/td\u003e\n\u003ctd\u003eAir-cooled, fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V 1-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic starter\u003c\/td\u003e\n\u003ctd\u003eFitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaker\u003c\/td\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eTank \u0026amp; Dimensions\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver\u003c\/td\u003e\n\u003ctd\u003e80 gallon, vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank outlet\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e37\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e74\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e720 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe data lists an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME-certified receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA recognition for the electrical components\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and states that the unit is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuilt in the USA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese do not constitute a third-party safety listing for the complete assembled machine. If your insurer, inspector, or corporate purchasing standard requires that specific listing, ask us before ordering so we can confirm the available manufacturer documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by freight throughout the lower 48, with shipping calculated at checkout based on your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e720 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, plan for a forklift, loading dock, or pallet jack at delivery. Terminal pickup may be an easier alternative when site unloading equipment is unavailable. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the pallet, crating, and tank for damage, and record anything you find on the delivery receipt with the driver present. A clean signed receipt can make freight damage claims difficult.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-Year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and may qualify for Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year “No Bull” coverage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, subject to manufacturer requirements. These may include purchasing the required maintenance kit with the compressor and registering the unit promptly. The extension cannot be added retrospectively, so confirm the exact requirements for this model before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45969733648437,"sku":"2020040726","price":4788.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/353DS80VCA20__25718.1685018187.1280.1280.webp?v=1788466262"},{"product_id":"quincy-air-compressor-473d80vcb20m-qt-max-7-5-hp-80-gallon-two-stage-208v-3-phase","title":"Quincy Air Compressor 473D80VCB20M QT Max 7.5 HP 80 Gallon Two Stage 208V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QT MAX 7.5 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers 22.6 CFM at 175 PSI from a two-stage cast-iron pump running at 1,725 RPM, with a vertical 80-gallon receiver built for shops where moisture control matters. Its standout advantage is the combination of an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler and automatic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which addresses condensate before it becomes a problem throughout the air system. The 208V three-phase configuration suits commercial facilities with that electrical service. Note: the unit measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\" × 74\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs 720 lbs, so verify ceiling clearance, floor capacity, and electrical requirements before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe aftercooler forces hot compressed air to cool immediately after leaving the pump, allowing moisture to condense at the compressor instead of farther downstream in your piping. That gives the automatic drain a chance to remove accumulated condensate from the receiver without relying on someone to open a manual valve. The pump also uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between compression stages, aluminum cylinder heads, two-piece connecting rods, splash lubrication with low-oil protection, and an oversized oil reserve. A magnetic starter provides controlled starting and thermal overload protection for the motor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis compressor is a strong fit for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebody shops, paint operations, automotive repair facilities, and commercial shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where consistent compressed-air performance and moisture management are important. It is particularly useful in buildings with long air runs or a history of condensate problems, and for businesses that want automatic tank drainage as part of their everyday operation. The 80-gallon vertical receiver saves floor space compared with a horizontal layout, while the 208V three-phase motor makes this configuration well suited to commercial electrical systems that already provide three-phase service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy the Aftercooler Matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompressed air leaves the pump hot and moisture-laden. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e drops the temperature before air enters the receiver, helping condensate separate where it can be drained instead of collecting throughout your piping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIt is not a substitute for a dryer on moisture-critical applications, but it removes much of the moisture load before downstream equipment has to handle it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Tank Drain\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eReceivers collect condensate, and a manual drain depends on someone remembering to use it. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e removes that step and helps prevent water from standing inside the receiver, reducing internal corrosion over time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSlow-Speed, Two-Stage Pump\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump runs at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,725 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22.6 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Its slow-speed design helps manage heat, vibration, and component wear during extended operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash-lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e pump includes low-oil protection and an oversized oil reservoir. The protection system shuts the compressor down if oil levels become unsafe, while the larger reservoir provides additional oil capacity for sustained operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCooling, Starting \u0026amp; Serviceability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA high-efficiency \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efinned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e cools air between compression stages, while aluminum heads help dissipate pump heat.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-piece connecting rods\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the motor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efactory-mounted magnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe vertical 80-gallon receiver measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\" × 74\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e720 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Check ceiling height, overhead service clearance, floor capacity, and access to the drain and outlet before delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Breaker and conductor sizing depend on the installation, so have a qualified electrician verify the circuit requirements from the motor data and local code. Confirm the voltage at your panel before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePerfect For\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBody shops and paint applications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommercial shops with 208V 3-phase power\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLong piping runs where moisture control matters\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperations that benefit from automatic condensate removal\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete compressor with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage cast-iron pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, aluminum heads, 7.5 HP motor and belt drive, finned intercooler, air-cooled aftercooler, automatic tank drain, low-oil protection, magnetic starter, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon vertical ASME-certified receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e shop piping, electrical disconnect, air dryer, or downstream filtration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e473D80VCB20M (QT MAX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e7.5 HP, electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump speed\u003c\/th\u003e\n\u003ctd\u003e1,725 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDelivery\u003c\/th\u003e\n\u003ctd\u003e22.6 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive, cast iron with aluminium head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eSplash lubricated, low-oil shutdown, extra-capacity reserve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMagnetic starter\u003c\/th\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended breaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003ctd\u003e80-gallon, vertical, ASME certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eAir cooled, fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTank drain\u003c\/th\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003ctd\u003e37\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e74\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e720 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCertification, Honestly\u003c\/h3\u003e\n\u003cp\u003eThe receiver is an ASME certified pressure vessel, and the manufacturer's data records a CSA marking with it. Those are two separate certifications covering two separate things: the pressure vessel code governs how the tank was designed, welded and inspected, while the electrical marking covers the motor and controls. Neither is evidence for the other.\u003c\/p\u003e\n\u003cp\u003eCheck the data plate on the machine when it arrives, since that is the document an inspector or an insurer will read and the only one that travels with the unit. If a specific listing is required by your code, your lease or your insurance policy, verify it against the plate before installation.\u003c\/p\u003e\n\u003ch3\u003eShipping and Delivery\u003c\/h3\u003e\n\u003cp\u003eFreight to the lower 48 states. The compressor weighs 720 lbs and ships upright on a pallet, so plan for a forklift, a loading dock, or a pickup arranged with the freight terminal. Delivery to a residential address carries a residential fee.\u003c\/p\u003e\n\u003cp\u003eInspect the machine before you sign the bill of lading. Look for damage to the guards and the aftercooler, a receiver that has moved in its bracing, and oil on the pallet, and note everything in writing while the driver is present. Signing clean and reporting later leaves you with very little.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eA 1-year factory warranty applies, extending to a 3-year \"No Bull\" warranty when Quincy's conditions are met. Those conditions are set at purchase and typically require the matching maintenance kit to be bought with the compressor and the unit to be registered with the manufacturer, so deal with both when you order. The supplied warranty documentation carries the governing terms.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45969740496949,"sku":"2020040725","price":4788.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/273D80VCB20M__73952.1679858654.1280.1280.jpg?v=1788466684"},{"product_id":"quincy-air-compressor-473d80vcb23m-qt-max-7-5-hp-80-gallon-two-stage-230v-3-phase","title":"Quincy Air Compressor 473D80VCB23M QT Max 7.5 HP 80 Gallon Two Stage 230V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QT MAX 7.5 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers 22.6 CFM at 175 PSI through a two-stage cast-iron pump feeding an 80-gallon vertical ASME-certified receiver. Its key advantage is the combination of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil protection and an extra-capacity oil reserve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e: the system shuts the compressor down if the oil level falls too low, helping prevent the bearing damage that can result when splash lubrication runs dry. The 230V three-phase motor is suited to commercial shop environments. Note: the unit measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\" × 74\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs 720 lbs, so verify ceiling clearance, floor capacity, and electrical requirements before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe QT MAX uses splash lubrication rather than the pressure-lubricated system found on Quincy's QP Pro platform, but it is designed to address a different set of maintenance concerns. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elarger oil reserve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides additional thermal capacity, helping the lubricant manage heat during operation, while the low-oil shutdown protects the pump when routine oil checks are missed. Its two-stage compression system uses a high-efficiency finned intercooler between stages to reduce the heat of compression, with cast-iron cylinders and aluminum heads for a combination of durability and heat dissipation. An air-cooled aftercooler further reduces discharge temperature, while the automatic tank drain removes condensate from the receiver.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis compressor is well suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebusy automotive repair shops, tire and exhaust operations, and multi-technician service bays\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need 7.5 HP of two-stage performance on a 230V three-phase supply. It is especially practical for shops where equipment sees frequent use but maintenance schedules can be difficult to keep perfect. The vertical 80-gallon receiver also keeps the footprint relatively compact, making it a useful choice when floor space is limited but ceiling height is available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQT MAX vs. QP Pro: The Honest Comparison\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy's two 80-gallon platforms use different lubrication systems. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQP Pro\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e uses pressure lubrication with a gerotor oil pump and spin-on filter. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e uses splash lubrication but adds \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil shutdown, an oversized oil reservoir, automatic tank drain, and an air-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eChoose based on your priorities: QP Pro for sustained heavy-duty operation where pressure lubrication is preferred; QT MAX for shops that prioritize oil-level protection and built-in moisture management.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat the Extra Oil Reserve Does\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe oversized oil reservoir provides more than additional capacity. More oil helps absorb pump heat, supporting cooler operation and slower oil degradation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe result is more stable lubrication between service intervals and better protection for internal components.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Stage Compression \u0026amp; Heat Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump compresses air in two stages, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between them. Cooling the air before the second stage reduces heat and supports efficient compression to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAluminum heads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e help dissipate heat, while cast-iron cylinders provide durability and dimensional stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduces discharge temperature before air enters the receiver, helping moisture condense inside the system rather than throughout the shop piping. The automatic tank drain removes accumulated condensate without relying on manual draining.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStarting \u0026amp; Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe factory-mounted \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides contactor-controlled starting and thermal overload protection. The pump uses two-piece connecting rods, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME-certified receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e includes the required pressure-relief hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe vertical receiver measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\" × 74\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e720 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Check ceiling height and allow additional overhead clearance for maintenance. Install on a flat, level, load-bearing surface.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis build requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Confirm the voltage at your panel before ordering. Have a qualified electrician size the breaker and conductors based on the motor data, run length, installation conditions, and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical work, site preparation, and permits are the customer's responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eBusy repair shops with extended daily air demand\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMulti-technician service bays\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTire, exhaust, and general automotive work\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShops replacing compressors that lacked low-oil protection\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete tank-mounted compressor with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage cast-iron pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, aluminum heads, 7.5 HP motor, belt drive and guard, finned intercooler, air-cooled aftercooler, automatic tank drain, low-oil protection, magnetic starter, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon vertical ASME-certified receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e piping, electrical disconnect, air dryer, or downstream filtration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e473D80VCB23M (QT MAX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e7.5 HP, electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDelivery\u003c\/th\u003e\n\u003ctd\u003e22.6 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive, cast iron with aluminium head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eSplash lubricated, oil sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLow-oil shutdown\u003c\/th\u003e\n\u003ctd\u003eFitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMagnetic starter\u003c\/th\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended breaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003ctd\u003e80-gallon, vertical, ASME certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eAir cooled, fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTank drain\u003c\/th\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003ctd\u003e37\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e74\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e720 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME certified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the manufacturer's data lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA marking\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These cover different things: ASME applies to the pressure vessel, while electrical markings apply to the motor and controls. Neither certifies the installation itself.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eVerify the actual data plate when the machine arrives. If your insurer, inspector, safety officer, or employer requires a specific listing, confirm it before connecting the compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by freight throughout the lower 48. At approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e720 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, plan for a forklift, loading dock, or terminal pickup. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the guards, aftercooler, drain fittings, and receiver bracing. Photograph and record any damage on the bill of lading with the driver present. A clean signed receipt can make freight damage claims difficult.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-Year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and may qualify for Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when the manufacturer's conditions are met. These generally include purchasing the required maintenance kit with the compressor and registering the unit. The supplied warranty documentation contains the definitive terms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45969747083317,"sku":"2020040727","price":4788.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/273D80VCB23M-3__90859.1679858980.1280.1280.webp?v=1788467245"},{"product_id":"quincy-air-compressor-473d80vcb46m-80-gallon-two-stage-460v-3-phase","title":"Quincy Air Compressor 473D80VCB46M 80 Gallon Two Stage 460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QT MAX 7.5 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers 22.6 CFM at 175 PSI from a two-stage cast-iron pump, paired with an 80-gallon vertical ASME-certified receiver and a 460V three-phase motor. Its biggest advantage is that the compressor is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuilt in the USA and designed with serviceability in mind\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, using components such as cast-iron cylinders, aluminum heads, belt drive, and two-piece connecting rods. That construction makes the pump practical to maintain and rebuild rather than treating the compressor as disposable equipment. Note: the unit measures approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" × 24\" × 74\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, weighs 720 lbs, and requires 460V three-phase power; verify electrical service and ceiling clearance before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump combines \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage compression with active heat and moisture management\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. A high-efficiency finned intercooler cools the air between stages, while the air-cooled aftercooler lowers discharge temperature after compression so moisture can condense before it reaches your air lines. An automatic tank drain then removes condensate from the receiver without relying on manual draining. The splash-lubricated pump also includes an extra-capacity oil reserve and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, which shuts the compressor down if the oil level drops too far and helps prevent damage from inadequate lubrication. A magnetic starter provides thermal overload protection and controlled motor starting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration is a strong fit for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emanufacturing plants, industrial facilities, multi-shift operations, and maintenance departments\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with 460V three-phase distribution. It makes particular sense for businesses that maintain their own equipment and value a compressor that can be serviced and rebuilt over time. The vertical receiver keeps the footprint to roughly 37\" × 24\", making efficient use of floor space, while the 74\" height means ceiling clearance should be checked before delivery. For facilities with long electrical runs, the 460V configuration also allows the 7.5 HP motor to operate at lower current than equivalent lower-voltage versions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned to Be Rebuilt\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis machine is built for serviceability: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron cylinders, aluminium heads, belt drive, and two-piece connecting rods\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The pump can be opened, inspected, rebuilt, and returned to service rather than treated as disposable equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIts \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUSA-built construction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e also matters for long-term serviceability, since rebuilds depend on replacement parts remaining available.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e460V Electrical Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e7.5 HP 460V motor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e draws roughly half the current of the same motor at lower voltage, allowing smaller conductors and reducing voltage drop on long runs. If your facility distributes 460V, this configuration is a strong fit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecannot be converted to lower voltage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Confirm your electrical service before ordering. Quincy does not specify a fixed breaker size; a qualified electrician must size the circuit based on the installation and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is included. Wiring, disconnects, permits, and site preparation are the customer's responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHeat \u0026amp; Moisture Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efinned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e cools air between stages, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduces discharge temperature and helps condense moisture before it reaches your air system. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e removes condensate from the receiver.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOil Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe splash-lubricated pump uses an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoversized oil reservoir and low-oil protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that stops the compressor if oil falls below a safe level.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe vertical 80-gallon unit measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e37\" L × 24\" W × 74\" H\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e720 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAllow clearance above the compressor for servicing the head and belts. Install it on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eflat, level, load-bearing surface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with access to the tank drain.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eIndustrial facilities with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V power\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShops that service or rebuild their own equipment\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstallations with long electrical runs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMulti-shift production requiring steady compressed air and moisture control\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eComplete tank-mounted package including:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo-stage cast-iron pump with aluminium heads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e7.5 HP motor, belt drive, and guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFinned intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir-cooled aftercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAutomatic tank drain\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e80-gallon vertical ASME-certified receiver\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e shop piping, electrical disconnect, dryer, or downstream filtration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e473D80VCB46M (QT MAX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e7.5 HP, electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDelivery\u003c\/th\u003e\n\u003ctd\u003e22.6 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive, cast iron with aluminium head\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eSplash lubricated, extra-capacity reserve, low-oil shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBuild\u003c\/th\u003e\n\u003ctd\u003eBuilt in the USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e460V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMagnetic starter\u003c\/th\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended breaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTank\u003c\/th\u003e\n\u003ctd\u003e80-gallon, vertical, ASME certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eAir cooled, fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTank drain\u003c\/th\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLength\u003c\/th\u003e\n\u003ctd\u003e37\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e74\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e720 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eC\u003cspan\u003eertification, Stated Plainly\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME certified\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the manufacturer's data lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA marking\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These have different scopes: ASME applies to the pressure vessel, while electrical safety markings apply to the motor and controls. One does not establish the other.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUSA-built\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e designation describes where the compressor is manufactured, not a certification.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhen the unit arrives, verify the markings on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edata plate\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. If your inspector, insurer, local code, or corporate standard requires a specific listing, confirm it before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight throughout the lower 48\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. At approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e720 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the upright pallet requires a forklift, loading dock, or prearranged terminal pickup. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the guards, aftercooler, drain fittings, and receiver bracing. Record any damage on the bill of lading with the driver present. Freight claims are difficult to recover after a clean signature.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-Year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and may qualify for Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when manufacturer conditions are met. These generally require purchasing the matching maintenance kit with the compressor and registering the unit. Arrange both at the time of purchase; the warranty documentation supplied with the machine governs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_d3b8351a-1757-4196-865f-73158a427bc3.pdf?v=1788468053\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45969753178165,"sku":"2020040728","price":4788.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/273D80VCB46M-3__16067.1679859159.1280.1280.jpg?v=1788467689"}],"url":"https:\/\/carliftsupply.com\/collections\/quincy-air-compressors.oembed","provider":"Car Lift Supply","version":"1.0","type":"link"}