{"product_id":"belaire-air-compressor-338vl4-7-5-hp-80-gallon-two-stage-460v-3-phase","title":"BelAire Air Compressor 338VL4 7.5 HP 80 Gallon Two Stage 460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBelAire 338VL4\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e combines \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e7.5 HP performance with a space-saving vertical design and 460V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Its 80-gallon ASME receiver stands upright, keeping the footprint to approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e39\" × 24\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e instead of occupying a long stretch of wall. Electrically, BelAire recommends a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e20 Amp breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making this configuration a practical choice for facilities that already have 460V three-phase service and want to minimize circuit requirements. The compressor uses a belt-driven two-stage pump with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast iron cylinder sleeve, aluminum heads, and an aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while a factory-installed magnetic starter provides motor switching and overload protection. Note: this model requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so confirm your electrical service before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage pump and aftercooler work together to manage heat and moisture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Air is compressed in two stages to support a maximum pressure of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the aftercooler reduces discharge temperature before the air reaches the tank. That helps moisture condense in the receiver rather than continuing downstream into your air system. The splash-lubricated pump includes an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for routine checks, and the fully enclosed high-flow belt guard protects the drive without restricting cooling airflow. Published airflow figures for this model differ, with available sources listing \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e18.5 CFM at 100 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e22.3 CFM at an unclear or conflicting rating pressure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so customers sizing the compressor for continuous-demand equipment should confirm the required CFM and pressure before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e338VL4 is built for industrial shops, plant rooms, and commercial facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with existing 460V three-phase distribution. It is particularly useful where \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efloor space and panel capacity are both limited\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the vertical tank makes efficient use of a corner or compressor room. At approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e77\" tall and 467 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, buyers should confirm ceiling clearance, the delivery route, and a level, solid installation surface before purchase. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3\/4\" tank outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e connects to downstream shop piping. An air dryer is not included; BelAire recommends the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCPXHT25\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e separately for applications requiring additional moisture control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ch4\u003eSupply and motor\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e460V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e7.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended breaker\u003c\/th\u003e\n\u003ctd\u003e20 amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw\u003c\/th\u003e\n\u003ctd\u003eConfirm with a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e\n\u003ctd\u003eMagnetic starter included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003ePump and air\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive, aluminum with cast iron sleeve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003e18.5 CFM at 100 PSI per the feature list; 22.3 CFM per the specification database and overview. Disputed — see the note above and confirm in writing if it decides your sizing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eOil lubricated, splash system, sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eTank and dimensions\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e80-gallon, vertical, ASME code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFootprint\u003c\/th\u003e\n\u003ctd\u003e39\" by 24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall height\u003c\/th\u003e\n\u003ctd\u003e77\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e467 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Without Gloss\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver is built and stamped to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME pressure-vessel code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and carries a safety valve. That is the certification claimed here: it concerns the tank, and it is verifiable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWhat we do not hold for this unit is a North American third-party electrical safety listing from an accredited testing laboratory. That type of listing covers the motor, starter and control wiring—areas a pressure-vessel code stamp says nothing about. The two are not interchangeable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInsurers, corporate facility standards and local electrical inspectors sometimes require an electrical listing by name. If there is any chance yours does, settle the question with us in writing before you order rather than after installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eDelivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFreight to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, priced live at checkout against your actual delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan the unload in advance: you will need a forklift or loading dock at the delivery point, or you can choose terminal pickup and collect it yourself. Residential delivery is available and carries a residential fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause the compressor ships standing tall, inspect the crate for lean or tipping as well as the usual transit damage—dents in the tank ends, a distorted guard or oil on the deck. Note any damage on the delivery paperwork and photograph it while the driver is still there. Damage discovered after a clean signature is very difficult to claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2-Year bumper-to-bumper factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e covers all components, with no additional purchase required. Record the serial number when the machine is uncrated and keep it with your invoice.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDo not disassemble the pump, motor or pressure switch before opening a claim. Taking a component apart to prove it failed is one of the easiest ways to jeopardize coverage. Report the fault first.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThen follow the manufacturer's oil-change interval, recheck belt tension after the first weeks of operation, and drain the tank daily while there is still pressure behind the water.\u003c\/span\u003e\u003c\/p\u003e","brand":"BelAire Compressors","offers":[{"title":"Default Title","offer_id":45997318406197,"sku":"338VL4","price":3666.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/338VL4__99825.1679576089.1280.1280.png?v=1789331717","url":"https:\/\/carliftsupply.com\/products\/belaire-air-compressor-338vl4-7-5-hp-80-gallon-two-stage-460v-3-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}