{"product_id":"chicago-pneumatic-air-compressor-7-5-hp-two-stage-1-phase","title":"Chicago Pneumatic Air Compressor 7.5 HP Two Stage 1 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eChicago Pneumatic RCP-C7581V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a 7.5 HP compressor built around a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e900 RPM pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, an important specification for buyers prioritizing durability and lower operating heat over maximum pump speed. Its all-cast-iron, two-stage pump delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e23 CFM at 100 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and reaches 175 PSI, while the 80-gallon vertical receiver provides substantial stored air for shop use. This model runs on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208–230V single-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it suitable for facilities without three-phase service. A magnetic starter is fitted for motor switching and overload protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe slow-turning pump is the key feature behind the machine's design. At \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e900 RPM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the pistons, rings, valves, and bearings cycle fewer times per hour than they would in a faster-running compressor, reducing the heat and mechanical activity associated with each operating hour. The all-cast-iron construction adds mass to the pump, helping it manage the heat generated during two-stage compression. Air is compressed in two steps with cooling between them before reaching the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI maximum\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, helping maintain pressure as the receiver is depleted. The result is a compressor designed around controlled operating speed and heavy pump construction rather than simply maximizing output from a compact machine.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis compressor is suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efour- to five-person automotive shops, one- to two-person body shops, and single-phase facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need a substantial air supply for intermittent tools and moderate sustained demand. The 80-gallon vertical tank saves floor space compared with a horizontal receiver, while the complete unit weighs approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e610 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and requires a solid, level installation surface. The 208–230V electrical supply should be confirmed with a qualified electrician before ordering, including available panel capacity, circuit protection, and conductor requirements. Allow adequate ventilation around the air-cooled pump, particularly if the compressor will operate for extended periods.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eOutput and pressure\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated flow\u003c\/th\u003e\n\u003ctd\u003e23 CFM @ 100 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStages\u003c\/th\u003e\n\u003ctd\u003eTwo stage, intercooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump RPM\u003c\/th\u003e\n\u003ctd\u003e900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eMotor, pump and supply\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e7.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eAll cast iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e208-230 Volt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhase\u003c\/th\u003e\n\u003ctd\u003e1-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMagnetic starter\u003c\/th\u003e\n\u003ctd\u003eFitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eTank, size and weight\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e80 Gallon, vertical, ASME\/CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall length\u003c\/th\u003e\n\u003ctd\u003e37\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e610 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir dryer\u003c\/th\u003e\n\u003ctd\u003eNot fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectronic drain valve\u003c\/th\u003e\n\u003ctd\u003eNot fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eManual draining is therefore part of the weekly routine. On a vertical receiver the drain sits under a tall column of condensate, so an accessible drain line is worth fitting if the tank ends up in a corner.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe manufacturer’s data lists an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME\/CRN pressure vessel with safety valves\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for the 175 PSI receiver. That certification applies to the tank—not the complete assembled machine.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical installation remains subject to local code, and any pressure-vessel inspection requirements apply to the receiver after installation. If your insurer, fleet standard or local inspector requires specific documentation for the complete installation, confirm the requirement with us \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e so we can verify what this model can document.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePalletized freight is available within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping quoted live at checkout based on your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e610 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, plan for a forklift, loading dock or suitable pallet jack on flat ground. The carrier delivers to the tailgate; unloading is your responsibility. If you do not have the necessary equipment, arrange carrier-terminal pickup. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the tank, pump, gauges and fittings \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore signing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Record any damage or shortages on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2-year full warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e covering the complete machine, including the valves, with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eno additional purchase required\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e according to the product listing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a problem develops, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estop the compressor, isolate it and contact us before disassembly\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Keep the pump assembled for inspection and document the fault with photographs before any work is performed.\u003c\/span\u003e\u003c\/p\u003e","brand":"Chicago Pneumatic","offers":[{"title":"Default Title","offer_id":45974532030517,"sku":"RCP-C7581V","price":4192.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/8090253637__26033.1679750891.1280.1280.png?v=1788635186","url":"https:\/\/carliftsupply.com\/products\/chicago-pneumatic-air-compressor-7-5-hp-two-stage-1-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}