{"product_id":"quincy-air-compressor-120-gallon-460v-3-phase","title":"Quincy Air Compressor 120 Gallon 460V 3 Phase","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy QP MAX 15 HP\u003c\/strong\u003e is the 460V three-phase version for shops that already have the right electrical service in place. It combines a two-stage cast-iron pump with a \u003cstrong\u003e120-gallon horizontal receiver\u003c\/strong\u003e and a listed \u003cstrong\u003e21-amp draw at 460V\u003c\/strong\u003e, reducing the conductor, conduit, breaker, and disconnect requirements compared with lower-voltage versions of the same compressor. The 78\" × 28\" × 55\" footprint works well in installations with limited ceiling height. Note: electrical sizing and installation should be handled by a certified electrician based on your actual service, run length, and local code.\u003c\/p\u003e\n\u003cp\u003eThe two-stage pump uses \u003cstrong\u003ecast-iron construction, aluminum heads, and a fin-and-tube intercooler\u003c\/strong\u003e to manage heat between compression stages. A mounted air-cooled aftercooler further reduces discharge temperature before air reaches the tank, helping moisture condense closer to the compressor. For lubrication and protection, the system includes a \u003cstrong\u003espin-on oil filter, positive-displacement gerotor oil pump, oil sight glass, and low-oil shutoff\u003c\/strong\u003e. Stainless steel reed valves with bumpers are designed for repeated cycling, while the 1\" tank outlet provides a substantial connection point for the shop's air system.\u003c\/p\u003e\n\u003cp\u003eThe QP MAX is a practical choice for \u003cstrong\u003eindustrial facilities, multi-bay automotive shops, fabrication operations, and manufacturing sites already equipped with 460V three-phase power\u003c\/strong\u003e. Its 995-lb weight calls for appropriate handling equipment and a level concrete slab, while the horizontal receiver makes it easier to work beneath lower ceilings than a comparable vertical configuration. If your facility uses single-phase power or three-phase service at a lower voltage, choose the QP MAX version designed for that supply rather than adding a transformer solely for the compressor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 78\" long by 28\" wide, plus the clearance needed for service and airflow. Treat the published dimensions as the machine's footprint, not the complete installation space.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 55\" to the top. Leave adequate clearance above the cooler for airflow and enough room around the tank and safety valve for inspection and service.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 995 lbs. Plan for a level concrete slab and appropriate mechanical equipment to position the compressor safely.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 460V, three-phase, with a listed current draw of 21 A. Quincy does not publish a specific breaker size for this unit and directs buyers to consult a certified electrician. The correct breaker and conductor sizing depend on the actual run length, installation conditions and applicable local code.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\" tank outlet, providing a substantial connection point for the shop's compressed-air piping.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe foundation, electrical feed, disconnect and connection to the compressed-air main are the customer's responsibility. Installation should be completed by appropriately licensed tradespeople in accordance with local requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Pump: Iron, Two Stages, and Filtered Oil Supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron construction with aluminum heads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and compresses air in two stages. A high-efficiency fin-and-tube intercooler between the stages cools the air before it enters the second stage, reducing thermal stress and improving compression efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStainless-steel reed valves with valve bumpers manage the intake and discharge cycles, while a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egerotor positive-displacement oil pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and spin-on oil filter provide the lubrication system. An oil sight glass makes the oil level easy to monitor, and a low-oil shutoff helps protect the pump if lubrication falls below a safe level.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDownstream of the pump, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emounted air-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduces discharge temperature before the compressed air reaches the receiver. That helps more moisture condense at the compressor rather than farther downstream in the shop's air piping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIndustrial and light-manufacturing facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that already have 460V, three-phase service.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMulti-bay service centers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where several technicians may be using compressed air simultaneously.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFabrication shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e running sanders, grinders and plasma equipment for extended periods.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities replacing an aging three-phase compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where the existing electrical feed and disconnect are already properly sized.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your building has single-phase power or three-phase service at a different voltage, this configuration is not the right match. The compressor family is available in versions designed for other electrical supplies, so match the compressor to the service available at the installation site.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package arrives as a complete, assembled compressor system consisting of the \u003c\/span\u003etwo-stage cast-iron pump, motor, 120-gallon horizontal receiver, magnetic starter, mounted air-cooled aftercooler, fin-and-tube intercooler, spin-on oil filter and oil sight glass.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e460V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw (as listed by Quincy)\u003c\/th\u003e\n\u003ctd\u003e21 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum heads, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e78\" long × 28\" wide × 55\" tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e995 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory warranty, extending to 3 years (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur records identify the receiver as built to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME pressure-vessel code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e among the unit's marks. Those certifications should be read specifically for what they cover: an ASME pressure-vessel certification applies to the tank, while a mark on the overall assembly does not necessarily satisfy every certification or listing requirement imposed by a local authority.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInsurers, fleet operators and certain jurisdictions may have specific requirements for permanently installed equipment. If that applies to your installation, verify the required listing or certification against the unit's data plate before purchase. We would rather resolve the question before the compressor ships than have it become an issue during inspection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBefore You Order — Please Confirm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA few specifications are reported differently across the available documentation. Rather than guess, we recommend confirming the following before ordering:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLubrication.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published descriptions of the oil system differ. The package name and feature list identify the compressor as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efully pressure-lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while a specification field records it as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. If the lubrication system is an important factor in your purchase, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm it with us in writing before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. We will obtain the answer directly from Quincy.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic tank drain.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The published information also differs on the tank drain. The description and one specification record indicate that an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic automatic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is fitted, while another specification states that it is not. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAsk us to confirm the configuration before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e if you are relying on an automatic drain.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDelivered air volume.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No CFM figure is published on this page because the available figure for this build is not accompanied by a verifiable unit of measure. Contact us and we will obtain the applicable factory figure.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePump speed.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No pump speed is published for this specific 460V configuration, so we have not substituted a figure from another model. Quincy documents lower pump speeds for related configurations at other voltages, but those figures should not be treated as specifications for this build. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAsk us and we will confirm the correct pump speed.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the current freight cost calculated at checkout for your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e995 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the compressor will arrive on a freight truck and the customer is responsible for unloading it. Plan for a suitable forklift or loading dock, or arrange terminal pickup if the delivery location cannot accommodate the shipment. Residential addresses are subject to an additional residential-delivery fee, which will be reflected in the freight quote at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the machine before accepting the shipment. Check the receiver, feet, guards, gauges and other exposed components for signs of shipping damage. If you find damage, document it and have it recorded on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading before signing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the option to extend coverage to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e subject to the terms and conditions in Quincy's warranty handbook.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe warranty handbook controls the actual coverage, exclusions and requirements, so review those terms before relying on the extended warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a fault occurs, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before anyone opens or dismantles the pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Unauthorized disassembly or repair can affect warranty eligibility. Keep the compressor intact until the manufacturer or authorized service provider has had an opportunity to evaluate the problem and advise on the next step.\u003c\/span\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45951997607989,"sku":"2020040920","price":11262.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3153D12HCB46M__96761.1679838533.1280.1280.png?v=1788125762","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-120-gallon-460v-3-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}