{"product_id":"quincy-air-compressor-15-hp-120-gallon-two-stage","title":"Quincy Air Compressor 15 HP 120 Gallon Two Stage","description":"\u003cp\u003eThe \u003cstrong\u003eQuincy QP MAX 15 HP two-stage compressor\u003c\/strong\u003e includes a mounted air-cooled aftercooler that removes much of the moisture from compressed air \u003cstrong\u003ebefore it reaches the 120-gallon receiver\u003c\/strong\u003e. By lowering discharge temperature at the compressor, the system helps prevent bulk condensation from traveling into shop piping, where it can reach air tools or spray equipment. The heavy-duty cast-iron pump with aluminum heads runs at \u003cstrong\u003e1,750 RPM\u003c\/strong\u003e, uses a belt drive, and is rated for 175 PSI. Note: this 208V three-phase model measures 78\" × 28\" × 55\" and weighs 995 lbs, with a listed electrical draw of 48.3A.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003etwo-stage compression system\u003c\/strong\u003e uses a fin-and-tube intercooler between stages to cool the air before final compression. This reduces thermal stress on valves and rings while improving compression efficiency at higher pressures. The 120-gallon receiver provides stored air for sudden demand and reduces how frequently the pump needs to load. A \u003cstrong\u003espin-on oil filter, gerotor positive-displacement oil pump, oil sight glass, and low-oil shutoff\u003c\/strong\u003e support routine maintenance and help protect the pump from lubrication-related damage. Note that this configuration does not include an air dryer, so applications requiring low-dew-point air will need separate downstream air treatment.\u003c\/p\u003e\n\u003cp\u003eThis compressor is suited to \u003cstrong\u003eindependent automotive repair shops, tire and fleet operations, body and fabrication shops, and light manufacturing facilities\u003c\/strong\u003e with multiple air-consuming tools or equipment. Its 175 PSI rating and 120-gallon storage make it a practical choice where steady shop air matters more than occasional garage use. The unit requires \u003cstrong\u003e208V three-phase power\u003c\/strong\u003e, and electrical installation, disconnect, site preparation, and shop piping are not included. A licensed electrician should determine the appropriate breaker and conductor sizing for the actual installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Two Stages, and Why Cast Iron\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA single-stage pump compresses ambient air to its final pressure in one step. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e divides that work between two compression stages, with a fin-and-tube intercooler between them. Cooling the air between stages gives the second stage cooler, denser air to compress and reduces the heat load on components such as the valves and rings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThat staged compression is one reason two-stage designs are well suited to higher-pressure and demanding applications. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron cylinders and aluminum heads\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e follow the same practical philosophy: cast iron provides durable cylinder surfaces and helps damp vibration, while aluminum heads transfer heat efficiently.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThere are five things to verify against your building before ordering:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFloor space.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The unit measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e78\" long × 28\" wide\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Allow additional working clearance around it so you can reach the belt guard, drain and oil fill without moving the compressor.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e At \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e55\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, it will fit beneath relatively low ceilings, but still requires adequate clearance around the cooler for unrestricted airflow.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFloor loading.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The compressor weighs approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e995 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and should be installed on a level, solid slab capable of supporting the equipment and suitable for mechanical handling.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Electrical supply is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V, three-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with a listed current draw of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e48.3 A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this configuration. Quincy does not publish a specific breaker size and directs buyers to consult a certified electrician. The appropriate breaker and conductor sizing depends on the actual electrical run, installation conditions and applicable local code.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir connection.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The receiver has a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\" tank outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing the connection point for the shop's compressed-air distribution system.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSite preparation, electrical feed, disconnect and connection to the shop's compressed-air piping are the customer's responsibility. The information on this page is not a substitute for an installation specification or for work performed by a properly licensed electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure, Storage and Why Tank Size Matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The receiver provides stored-air capacity between compressor load cycles and helps absorb short periods of higher demand without requiring the pump to respond instantly to every fluctuation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA larger receiver can also help reduce unnecessary cycling when demand varies, although the appropriate tank size ultimately depends on the compressor's output, operating pressure and application.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Oil Circuit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump is equipped with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003espin-on oil filter, Gerotor positive-displacement oil pump, oil sight glass and low-oil shutoff\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The system circulates and filters the lubricant, provides a visual way to check oil level and helps protect the pump from operation when the oil level becomes too low.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe spin-on filter also simplifies routine maintenance, allowing the consumable filter to be replaced without extensive disassembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eIndependent repair shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e supplying several service bays from one compressor.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTire and fleet operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with frequent impact-tool use and sustained air demand.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBody and fabrication shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e using sanders, plasma equipment or other pneumatic tools that require a steady supply.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLight manufacturing facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that already have compatible three-phase electrical service.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor arrives as an assembled package consisting of the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron two-stage pump, motor, 120-gallon horizontal receiver, magnetic starter, mounted air-cooled aftercooler, high-efficiency fin-and-tube intercooler, spin-on oil filter and oil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e208V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw (as listed by Quincy)\u003c\/th\u003e\n\u003ctd\u003e48.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum heads, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump speed\u003c\/th\u003e\n\u003ctd\u003e1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e78\" long × 28\" wide × 55\" tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e995 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eMounted air-cooled aftercooler; fin-and-tube intercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory warranty, extending to 3 years (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur product record identifies the receiver as built to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME pressure-vessel code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e among the unit's marks. These are not interchangeable certifications, and the relevant requirement is the one specified by your inspector, insurer or facility policy.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn ASME pressure-vessel designation applies to the receiver and its construction; it should not be interpreted as a blanket certification of the complete electrical assembly. If your site requires a particular certification or listing for permanently installed equipment, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003everify it against the unit's data plate before purchase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rather than after installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eThree Things to Confirm Before You Order\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished information for this package differs on three points. We are flagging each discrepancy rather than choosing the version that appears most favorable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHow the pump is lubricated.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The manufacturer's package name and feature list describe the compressor as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efully pressure-lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while a specification field on this page records the oil system as \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubricated\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These describe different lubrication systems. If pressure lubrication is an important reason for choosing this model, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm it with us in writing before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and we will obtain the current factory specification from Quincy.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eThe automatic tank drain.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The product description, feature list and one specification record indicate that an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic automatic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is included, while another specification record lists none. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIf an automatic drain is a requirement, confirm the configuration with us before ordering.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDelivered air volume.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The published CFM figure for this machine is also associated with a unit of measure that we cannot independently verify. Rather than publish an ambiguous performance number, we have left it off this page. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAsk us and we will obtain Quincy's applicable factory airflow rating in writing before you order.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the current freight cost calculated at checkout for your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e995 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the machine requires suitable unloading equipment. Arrange a forklift or loading dock with adequate capacity, or choose terminal pickup if your delivery location cannot safely unload the shipment. Residential addresses are subject to an additional residential-delivery fee, which will be reflected in the freight quote at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the shipment before signing the delivery paperwork. Check the pallet, receiver, belt guard, gauges, feet and other exposed components for visible damage. If you find anything wrong, document it and have the damage recorded on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebill of lading while the driver is present\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with coverage extendable to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e subject to the conditions in Quincy's warranty handbook.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe warranty handbook is the governing document, and the extended coverage is conditional. Review the requirements before assuming the additional coverage applies to your installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf something goes wrong, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before disassembling the pump or other major components\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Opening the equipment before a warranty claim has been evaluated can complicate the manufacturer's assessment and may affect eligibility. Contact us first, document the problem and wait for instructions before beginning repairs.\u003c\/span\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954237005877,"sku":"2020040918","price":11262.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3153D12HCB20M__13328.1679861756.1280.1280.webp?v=1788207014","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-15-hp-120-gallon-two-stage","provider":"Car Lift Supply","version":"1.0","type":"link"}