{"product_id":"quincy-air-compressor-40-hp-tankless-rotary-screw-with-dryer-230-460v-3-phase","title":"Quincy Air Compressor 40 HP Tankless Rotary Screw with Dryer 230\/460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4152028080\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a 40 HP gear-driven rotary screw compressor designed to deliver continuous air from a surprisingly compact cabinet. It measures \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e55.1\" long × 30.7\" wide × 49.2\" high\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs 1,087 lbs, making its 49.2\" height the standout feature for installations with limited headroom. The 100% duty cycle package includes an integrated refrigerated air dryer, while the tankless design lets you pair the compressor with a receiver sized and positioned for your specific air system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003egear-driven airend\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e eliminates belt tensioning, belt replacement and power loss from belt slip. The TEFC motor includes \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIP 55 wash-down protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and Wye-Delta reduced-voltage starting, while the refrigerated dryer removes moisture before it reaches your distribution system. An aftercooler, spin-on fluid filter, oil sight glass, constant fluid monitoring and low-oil shutdown on both engine and pump support continuous operation. The Infologic2 Basic Controller adds programmable auto-restart, remote start\/stop and networking capability for up to six QGS compressors, with the display providing pressure, temperature and dewpoint information. The result is a compact package that combines compression and air treatment without requiring a separate dryer cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFor installation, plan around the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e55.1\" × 30.7\" footprint and 49.2\" height\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with additional clearance for the hinged doors, detachable panels and cooling airflow. The compressor requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e230\/460V 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e; Quincy does not publish an amp draw or breaker size, so a certified electrician should size the feeder and protection from the machine's nameplate. The compressor is supplied \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ewithout a receiver tank\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so existing or separately specified storage is required. No electronic drain valve is fitted.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration suits \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emanufacturing facilities, plant rooms and production shops with limited headroom\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, as well as operations that already have a receiver and want to add compressor capacity without duplicating storage. It is especially useful where continuous air demand, integrated drying and a compact installation footprint all matter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit? Siting and Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThe cabinet.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 55.1\" x 30.7\" x 49.2\" and 1,087 lbs. Measure your doorway and headroom against those numbers before ordering; a compressor that fits the room but not the route into it is a genuinely common and expensive mistake. Leave working space around the hinged doors and detachable panels. The machine is designed for service access from the outside, but only if you have not built shelving or equipment against it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Listed as 230\/460V AC, 3-Phase. Quincy publishes neither an amp draw nor a recommended breaker size, stating instead that a certified electrician should be consulted, and we will not put a number in that gap. Your electrician should size the feeder and overcurrent protection from the nameplate on the delivered machine. Have that conversation before delivery, not after it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eHeat.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A machine rated for a 100% duty cycle is designed to run continuously, and the electrical energy it consumes ultimately becomes heat that must be removed from the room. A small cabinet does not produce less heat than a larger one; it simply concentrates the equipment into a smaller footprint. Plan ventilation accordingly. Confirming that the installation site can accommodate the machine's power, heat and service requirements is the customer's responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy a Small Cabinet Is Worth Paying Attention To\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFloor space in a working shop is not free, and plant rooms are often whatever space was left over. A 40 HP package measuring just 55.1\" long and 49.2\" tall can change what is possible: it can sit beneath an existing mezzanine, tuck under low ductwork, or run against the wall of a service bay instead of consuming a corner of the shop floor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tankless configuration is part of that same argument. Because the receiver is separate, you can position it where it makes the most sense for your installation, including outside the building or in an elevated location where permitted by the installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe trade-off is straightforward: if you do not already have a suitable receiver, you will need to purchase one. A tankless compressor connected directly to the shop main is not a complete compressed-air storage system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGear Drive, and a Dryer Inside the Same Enclosure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe airend is gear driven rather than belt driven. There is no drive belt to tension or replace, and no belt slip between the motor and airend. On a machine designed for continuous operation, eliminating that wear item simplifies the maintenance schedule and removes one potential source of power transmission loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe motor is a TEFC design with IP 55 wash-down protection, and the package uses a Wye-Delta reduced-voltage start to reduce electrical inrush during startup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe refrigerated air dryer is integrated into the enclosure. Compressed air can carry moisture downstream, where it can contribute to corrosion in piping and equipment and create problems for applications sensitive to water contamination. Removing that moisture as part of the compressor package simplifies the installation and avoids dedicating separate floor space to a dryer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn aftercooler, oil sight glass, spin-on fluid filter, constant fluid monitoring and low-oil shutdown on both engine and pump complete the package.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eControl is handled by the Infologic2 Basic Controller, with programmable auto-restart and remote start\/stop. It can network up to six QGS compressors, while the display provides pressure, temperature, dewpoint, motor-start and general status information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops short on floor space.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The 49.2\" height and 55.1\" length are the main advantages of this configuration.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePlant rooms with low headroom.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Useful beneath mezzanines, ductwork or other overhead restrictions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities that already own a receiver.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The tankless configuration avoids paying for another receiver when suitable storage is already available.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eContinuous production air.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The 100% duty-cycle rating is designed for sustained operation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy lists this package as the gear-driven QGS rotary screw compressor, the Infologic2 Basic Controller with display panel, the 100% duty-cycle TEFC motor and the integrated refrigerated air dryer, together with an aftercooler, oil sight glass, pressure gauge, air filter and low-oil shutdown on both engine and pump.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor power\u003c\/th\u003e\n\u003ctd\u003e40 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFree air delivery (CFM)\u003c\/th\u003e\n\u003ctd\u003e154.9 at 125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSound level (dBA)\u003c\/th\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor enclosure\u003c\/th\u003e\n\u003ctd\u003eTEFC, IP 55 wash-down, Wye-Delta start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, gear drive, oil lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntegrated refrigerated dryer\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver tank\u003c\/th\u003e\n\u003ctd\u003eNone supplied, listed as 0 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage and phase\u003c\/th\u003e\n\u003ctd\u003e230\/460 Volt AC, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw and breaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,087 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions, L x W x H\u003c\/th\u003e\n\u003ctd\u003e55.1\" x 30.7\" x 49.2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn ASME certification is recorded on the specification sheet for this unit. Be precise about what that means: ASME coding applies to pressure vessels, while this configuration ships without a receiver — the listed tank capacity is 0 gallons. If a coded vessel is what your inspector or insurer requires, that question belongs to the receiver you connect to this compressor. We will confirm exactly what the certification on this SKU covers before you commit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eSeparately, our product data records no independent electrical or equipment safety listing for the packaged machine, and we are not going to imply that one exists. If your jurisdiction, insurer or corporate standard requires an independent third-party listing for installed equipment, establish that requirement before purchase rather than discovering it at inspection.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by freight within the lower 48 states, with the shipping cost quoted live at checkout based on the delivery address you enter rather than estimated on this page. At 1,087 lbs, the unit requires a dock or forklift for unloading. If you have neither, terminal pickup from the carrier is the alternative.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential delivery carries a residential fee, shown at checkout where applicable. Inspect the crate before signing and record any damage on the bill of lading at the time of delivery. Once a clean bill is signed, a concealed-damage claim becomes much more difficult to pursue. Take photographs while the driver is still on site; those are often the evidence that makes a freight claim straightforward.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished standard coverage is 1 Year for consumer use and 1 Year for commercial use. An extended 3-Year factory warranty is available, and the True Blue 5-Year warranty applies when a Quincy-authorized start-up commissions the machine.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThat distinction matters: the longest warranty term depends on who performs the start-up, so the decision needs to be made before the compressor is first energized, not after it is already in service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWhatever warranty term applies, do not open the airend, dryer circuit or motor before a claim has been raised and assessed. A disassembled component may be treated as an unverifiable failure and can complicate warranty coverage. Keep the commissioning paperwork together with your fluid and filter service records; both may be requested when a claim is evaluated.\u003c\/span\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45954987163701,"sku":"4152028080","price":24170.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152028080__02831.1679919906.1280.1280.jpg?v=1788223912","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-40-hp-tankless-rotary-screw-with-dryer-230-460v-3-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}