{"product_id":"quincy-air-compressor-4103d12vcb46m-qt-max-10-hp-120-gallon-two-stage-460v-3-phase","title":"Quincy Air Compressor 4103D12VCB46M QT Max 10 HP 120 Gallon Two Stage 460V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 10 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is built for continuous-duty shops where protecting the compressor matters just as much as producing air. Its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo independent shutdown systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e address two different failure modes: a factory-fitted magnetic starter with thermal overload protection helps prevent motor damage from overload conditions, while a low-oil cut-off stops the pump if the oil level falls too far. Behind those safeguards is a splash-lubricated cast-iron two-stage pump delivering \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e35 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e into a 120-gallon vertical ASME receiver. Note: this configuration requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe protection systems are especially useful when the compressor runs for long periods without constant supervision. The magnetic starter monitors motor load and can shut the unit down during an overload condition, while the low-oil cut-off directly protects the pump from operating with insufficient lubrication. An \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a quick visual check before operation, so routine inspection can catch a problem before either shutdown has to intervene. The two-stage pump also uses a finned intercooler and air-cooled aftercooler to control compression temperatures during extended operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis model is suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomotive repair shops, fleet facilities, fabrication operations and other commercial applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that already have 460V three-phase service and need a compressor capable of sustained use. Its vertical receiver keeps the floor footprint around \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40\" × 30\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, but the approximately 75\" overall height and 1,000 lb weight require a suitable installation area. Provide a solid, level concrete pad, adequate airflow around the cooling components and enough clearance for service access.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTwo details should be confirmed before purchase. The available information lists different model codes, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4103D12VCB46M and 2103D12VCB46M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e; provide the code from your quote or purchase order so the exact build can be verified. Published information also conflicts on the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic electronic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with some sources listing one and the specification field saying it is not fitted. If that feature is important to your installation, confirm the configuration in writing before ordering. Electrical feeder, disconnect and protection sizing should be determined by a certified electrician for your specific 460V service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo things to check before ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThe part number.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Our title, description and specifications list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e4103D12VCB46M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the page URL and one sentence list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e2103D12VCB46M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Send us the code on your quote or purchase order and we will confirm the correct build with the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThe automatic tank drain.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The feature list and description say an automatic electronic drain is included, while the specification field says it is not. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIf the automatic drain matters to your purchase, ask us to confirm it in writing before ordering.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo layers of protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe factory-installed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e includes an overload relay that protects the motor from excessive current caused by conditions such as a stalled pump or phase failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil cutoff\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e protects the pump from a different problem: insufficient lubrication. It shuts the compressor down if the oil level becomes dangerously low. An \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a quick visual check before operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy 460V matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis version is designed for facilities with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Higher voltage generally means lower current for the same power output, which can allow smaller conductors and feeders than lower-voltage configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy does not specify a universal breaker size because the correct selection depends on the installation and local code. Have a certified electrician confirm the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efeeder, disconnect and protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before ordering. This model is factory-wired for 460V and is not field-convertible to another voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned to run cool\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe QT MAX pump operates at a deliberately low speed to reduce heat and wear, supporting its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty-cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e design. A finned intercooler between compression stages and an air-cooled aftercooler before the tank provide additional temperature control.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe vertical package occupies approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40\" × 30\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of floor space, stands about \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e75\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,000 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCheck ceiling height, doorways and the complete delivery route before ordering. Install it on level, solid concrete with sufficient clearance for cooling airflow and service access.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003e4103D12VCB46M (a second code appears in our data - see above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP, 460 Volt, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003e35 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum head, enclosed belt drive, splash lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor protection\u003c\/th\u003e\n\u003ctd\u003eMagnetic starter with thermal overload, factory wired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump protection\u003c\/th\u003e\n\u003ctd\u003eLow oil cut-off switch, oil sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eFinned interstage intercooler and air-cooled aftercooler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003e120 gallon, vertical, ASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e40 inches by 30 inches, 75 inches tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,000 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAutomatic tank drain\u003c\/th\u003e\n\u003ctd\u003ePublished details differ - confirm before ordering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory, extending to a 3-year term on the manufacturer conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003ePerfect For\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities with 460V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that want to match their existing service.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eUnattended or continuous operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, where built-in protection helps prevent major damage.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eProduction shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e running blasting, finishing or assembly equipment continuously.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMaintenance teams\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that value automatic shutdown protection.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eWhat's In The Box\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe factory-assembled package includes the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etwo-stage pump, motor, enclosed belt drive and guard, 120-gallon vertical receiver, magnetic starter, low-oil cutoff, oil sight glass, intercooler and aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe buyer supplies the electrical feed, disconnect and protection, downstream piping, additional filtration or drying, isolation pads and first-service consumables. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNo air dryer is included.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, stated honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe manufacturer lists an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME tank with UL and CSA marks\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These certifications apply to the equipment as manufactured, not to the installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eYour electrician must verify the feeder, disconnect, overcurrent protection and ventilation requirements for your site. If your insurer or local authority requires additional documentation, ask us before ordering so we can obtain it from the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping and Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis compressor ships by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout. Residential deliveries may incur an additional fee. Commercial delivery with a dock or forklift, or terminal pickup, may be more practical.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,000 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, suitable unloading equipment is required. Inspect the crate and compressor before signing and document any damage on the bill of lading.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe unit includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with eligibility for an extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year term\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when the manufacturer's registration and maintenance requirements are met. Confirm the current conditions with us before purchase.\u003c\/span\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45960191836213,"sku":"2020040785","price":7802.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2103D12VCB46M__61092.1679852719.1280.1280.webp?v=1788280793","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-4103d12vcb46m-qt-max-10-hp-120-gallon-two-stage-460v-3-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}