{"product_id":"quincy-air-compressor-4153d12hca20m-qt-max-15-hp-120-gallon-two-stage-208v-3-phase","title":"Quincy Air Compressor 4153D12HCA20M QT Max 15 HP 120 Gallon Two Stage 208V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QT MAX 15 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e51 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% continuous-duty rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making it built for sustained shop air demand rather than short bursts. The package combines a 15 HP motor with a splash-lubricated, cast-iron two-stage pump, a 120-gallon horizontal receiver, and a conservative 1,750 RPM operating speed. Quincy rates the pump for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emore than 50,000 hours of service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, giving this compressor the capacity and operating design needed when multiple air-powered tools may be running throughout the day.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with connecting-rod dippers circulating oil through the crankcase. This straightforward system reduces the number of components involved in lubrication, while the oil sight glass makes the level easy to check. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil cutoff switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e shuts the compressor down if the oil level becomes too low, helping protect the pump from damage. Heat management is also built around continuous operation: a high-efficiency finned intercooler cools the air between compression stages, while built-in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercoolers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduce discharge temperature before air enters the receiver and help remove moisture from the compressed air.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor electrical protection, the unit includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and is designed for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The 15 HP motor draws 48.3 amps according to Quincy’s published information, while the 1-inch tank outlet provides the connection point for the shop’s compressed-air system. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 15 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a strong fit for multi-bay automotive shops, dealerships, tire and fleet operations, fabrication facilities, and other professional environments where several technicians may depend on consistent air supply. Its 100% duty cycle makes it particularly useful for shops that have outgrown compressors that need frequent recovery periods.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSplash Lubrication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash-lubricated pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a simple, low-component design. Connecting-rod dippers circulate oil through the crankcase, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e makes level checks easy and the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elow-oil cut-off\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e protects the pump from damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for Heat Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efinned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e cools air between compression stages, reducing second-stage workload and valve temperatures. Built-in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercoolers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e lower discharge temperature and condense much of the moisture before it reaches the tank and air system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps protect the three-phase motor from overload and phase-loss conditions. Combined with the low-oil cut-off, it provides protection against common compressor failures.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDimensions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 78\" L × 28\" W × 55\" H\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 923 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 208V, 3-phase\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAmp draw:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 48.3 A\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir connection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir output:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 51 CFM\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eMulti-bay service centers and dealerships\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eTire and fleet operations\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eFabrication shops and spray booths\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShops needing sustained air volume throughout the day\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e15 HP two-stage cast-iron pump\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter with thermal overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt-in air-cooled aftercoolers\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-efficiency finned intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil cut-off switch\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir delivery\u003c\/th\u003e\n\u003ctd\u003e51 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003eContinuous, 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e208V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw (as listed by Quincy)\u003c\/th\u003e\n\u003ctd\u003e48.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage cast iron, splash lubricated, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump speed\u003c\/th\u003e\n\u003ctd\u003e1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e1\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e78\" long × 28\" wide × 55\" tall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e923 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor protection\u003c\/th\u003e\n\u003ctd\u003eMagnetic starter with thermal overload; low-oil cut-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ereceiver is built to the ASME pressure-vessel code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and the specification record also lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. These certifications apply to the tank, not necessarily the complete compressor assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBefore You Order — Please Confirm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWarranty:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published information shows two different warranty structures. One lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory coverage extending to 3-year “No Bull” coverage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Another lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year parts and labor, 2-year package and 3-year pump coverage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, conditional on purchasing and registering an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEWK-5 Maintenance Kit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eContact us to confirm the current factory terms in writing before ordering.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic tank drain:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published specifications conflict on whether an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic automatic drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is included. Confirm with us if this feature is important to you.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e923 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the unit requires a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eforklift, loading dock or terminal pickup\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Residential deliveries incur an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the compressor before signing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and record any damage on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause the published warranty terms conflict, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm the applicable coverage before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The baseline listed is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory coverage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with extended protection available under specific conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_3ce74cdc-ecb2-4083-9ab9-8bd400181f40.pdf?v=1788314844\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45964077203509,"sku":"2020040894","price":9591.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2153D12HCA20M__75580.1679839687.1280.1280.png?v=1788353421","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-4153d12hca20m-qt-max-15-hp-120-gallon-two-stage-208v-3-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}