{"product_id":"quincy-air-compressor-453d80vcb46m-qt-max-80-gallon-two-stage","title":"Quincy Air Compressor 453D80VCB46M QT Max 80 Gallon Two Stage","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQT MAX 5 HP air compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is built for shops that need to pair reliable compressed air with a refrigerated dryer. Its factory-installed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e removes much of the moisture before the air reaches your dryer, reducing the amount of bulk condensate the dryer has to handle. The result is a better-prepared air supply for downstream drying equipment. The compressor combines a splash-lubricated cast iron two-stage pump, an 80-gallon vertical ASME receiver, and a factory magnetic starter. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRequires 460V 3-Phase power.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe aftercooler is the key advantage for moisture-sensitive compressed-air systems. Hot, moisture-laden air leaving the pump is cooled before entering the receiver, allowing much of that moisture to condense at the tank rather than farther down the air lines. It does not replace a refrigerated dryer, but it \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ereduces the bulk moisture load\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reaching it so the dryer can focus on removing the remaining water vapor. A separate finned intercooler between the pump's two compression stages also helps control operating temperature by cooling the air before the second stage. Combined with the pump's slow rotation, cast iron construction, and low-oil shutdown, these features support the manufacturer's stated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000+ hour pump life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis configuration is well suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eprofessional shops already running a refrigerated dryer or planning to install one\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, particularly where moisture control directly affects the finished work. Paint and finishing operations, plasma cutting, blast cabinets, automotive service facilities, and plants with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V three-phase distribution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e can all benefit from having moisture reduced before air reaches the rest of the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Things to Confirm Before Ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePart number:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The title and specifications list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e453D80VCB46M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the description and page URL list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e253D80VCB46M\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Send us the model number on your paperwork so we can confirm the exact build and voltage with the manufacturer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eTank drain:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published details conflict. The feature list and detailed specifications indicate an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic automatic drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while another field says no drain is fitted. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIf the drain is important to your application, ask us to confirm it in writing before ordering.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage, Space \u0026amp; Access\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis model requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. If your facility uses a different three-phase voltage, contact us for the correct model.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 37\" × 24\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 74\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 680 lbs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eBreaker:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Not specified; consult a certified electrician\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eConfirm the electrical supply, breaker requirements, ceiling clearance, delivery access and floor capacity before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy the Aftercooler Matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCompressed air leaves the pump hot and moisture-laden. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduces the temperature before air enters the receiver, causing much of the moisture to condense in the tank instead of downstream piping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis helps reduce water and corrosion and allows a refrigerated dryer to work more efficiently. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAn aftercooler does not replace a refrigerated dryer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when genuinely dry air is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCast Iron, Cooled Twice\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efinned intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e cools the air between compression stages, improving efficiency and reducing discharge temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe slow-speed cast-iron pump features:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eAluminum heads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTwo-piece connecting rods\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eManufacturer-rated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50,000+ hour pump life\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eShops using or planning to add a refrigerated dryer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePaint, powder coating and finishing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePlants with 460V three-phase power\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePlasma cutting and blast cabinets\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCast-iron two-stage pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e5 HP motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e80-gallon vertical ASME receiver\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFinned intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir-cooled aftercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass and gauges\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir delivery\u003c\/td\u003e\n\u003ctd\u003e17.2 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum pressure\u003c\/td\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump\u003c\/td\u003e\n\u003ctd\u003eTwo-stage, splash lubricated, cast iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eAir treatment\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAftercooler\u003c\/td\u003e\n\u003ctd\u003eAir-cooled, fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntercooler\u003c\/td\u003e\n\u003ctd\u003eFinned, between stages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir dryer\u003c\/td\u003e\n\u003ctd\u003eNot fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePower, Tank \u0026amp; Size\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e460V 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver\u003c\/td\u003e\n\u003ctd\u003e80 gallon, vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank outlet\u003c\/td\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFootprint\u003c\/td\u003e\n\u003ctd\u003e37\" by 24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e74\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e680 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur data supports an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e on the electrical components, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUS manufacture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e as stated in the feature list.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eWe do not claim a third-party safety listing for the complete machine assembly. Component approvals are separate from certification of the finished unit. If your plant standards or insurer require a specific listing, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eask before ordering and we will confirm it with the manufacturer\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFreight shipping is available throughout the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the rate calculated at checkout based on your address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAt \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e680 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, unloading requires a forklift, loading dock or terminal pickup. Residential delivery carries an additional fee, and terminal pickup may be the simpler option.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eInspect the shipment before signing.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Check the crate, tank, gauges and starter enclosure, and record any damage on the bill of lading in front of the driver.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty covering parts and labor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-Year \"No Bull\" Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e may extend coverage when the required maintenance kit is purchased with the compressor and the unit is registered promptly. Confirm the exact requirements for this model \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, as the extension cannot be added later.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_1.pdf?v=1788356477\"\u003eWarranty Details\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45964686426165,"sku":"453D80VCB46M","price":4504.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/253D80VCB46M__24585.1679853597.1280.1280.png?v=1788358078","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-453d80vcb46m-qt-max-80-gallon-two-stage","provider":"Car Lift Supply","version":"1.0","type":"link"}