{"product_id":"quincy-air-compressor-50-hp-tankless-rotary-screw-230-460v-3-phase","title":"Quincy Air Compressor 50 HP Tankless Rotary Screw 230\/460V 3 Phase","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eQuincy QGS 50 HP rotary screw compressor\u003c\/strong\u003e provides continuous-duty compressed air without an integrated dryer or receiver, making \u003cstrong\u003ePart #4152016900\u003c\/strong\u003e a practical choice for facilities that already have centralized air storage and treatment. Its \u003cstrong\u003egear-driven airend\u003c\/strong\u003e eliminates belt maintenance and is built for a \u003cstrong\u003e100% duty cycle\u003c\/strong\u003e, while the included aftercooler manages discharge temperature before air enters your existing downstream system. Note: the machine ships wired for \u003cstrong\u003e460V 3-phase\u003c\/strong\u003e and includes a conversion kit for \u003cstrong\u003e230V 3-phase\u003c\/strong\u003e; electrical conversion and circuit sizing require a qualified electrician.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003egear drive\u003c\/strong\u003e connects the motor directly to the airend without belts to tension or replace, making it well suited to long, uninterrupted operating periods. A TEFC motor with \u003cstrong\u003eWye-Delta reduced-voltage starting\u003c\/strong\u003e helps control electrical inrush during startup, while synthetic lubrication, fluid monitoring, spin-on filters, and low-oil shutdown support reliable continuous operation. The \u003cstrong\u003eInfologic2 Basic Controller\u003c\/strong\u003e provides pressure and temperature readings, alarm and auto-run indication, programmable operation, auto-restart, remote start\/stop, and networking for up to six QGS units. Because this SKU has \u003cstrong\u003eno receiver or integrated dryer\u003c\/strong\u003e, your existing plant system remains responsible for storage and final air treatment.\u003c\/p\u003e\n\u003cp\u003eThis configuration is best suited to \u003cstrong\u003eindustrial facilities with centralized air treatment\u003c\/strong\u003e, shops that already have a suitable receiver, and multi-compressor rooms where several QGS units need coordinated control. The cabinet measures approximately \u003cstrong\u003e52\" L × 37.7\" W × 61.3\" H\u003c\/strong\u003e and weighs \u003cstrong\u003e1,184 lbs\u003c\/strong\u003e, so plan for adequate service clearance, ventilation, and a suitable installation surface. If you need a self-contained package with its own tank and dryer, the dryer-equipped version is the better fit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit? Siting \u0026amp; Power\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eFootprint.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The cabinet measures 52\" L × 37.7\" W × 61.3\" H and weighs 1,184 lbs. It is deeper and more square than the dryer-equipped version of this 50 HP machine, so do not assume that model’s footprint applies. Leave adequate clearance for hinged doors and removable panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Rated for 230\/460V AC, 3-phase. It ships wired for 460V-3 with a kit for 230V-3; conversion should be performed by a licensed electrician. Quincy does not publish amp draw or breaker size, so your electrician should size the feeder and protection from the machine nameplate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eAir treatment is separate.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e This SKU has no integrated dryer. Moisture not removed by the aftercooler continues downstream into your piping. If your system requires dry air, specify the appropriate dryer and filtration separately. Site power, ventilation, air treatment and installation are the customer's responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned for Central Air Treatment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBuilt-in treatment is convenient for a standalone compressor; centralized treatment makes more sense in many multi-compressor plants. One central dryer can serve multiple machines while allowing different air-quality requirements for different applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis tankless, dryer-less configuration leaves storage and air treatment decisions to your facility. It is not a complete air system by itself: the specification lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0-gallon tank capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so a receiver must be provided separately, as must drying equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf you want the compressor, receiver and dryer packaged together, choose the packaged version.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGear Drive \u0026amp; Continuous Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe airend is gear driven, eliminating belt tensioning and replacement. A \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rating supports continuous operation rather than intermittent use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePremium synthetic lubrication, low oil carryover, constant fluid monitoring, spin-on fluid filters, an oil sight glass and low-oil shutdown protect the system during extended operation. The TEFC motor uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWye-Delta reduced-voltage starting\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to reduce starting inrush.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA full sound enclosure helps control operating noise and vibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eInfologic2 Basic Controller\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e supports programmable operation, auto-restart, remote start\/stop and networking for up to six QGS units. The display provides run and alarm status along with pressure and temperature readings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePlants with central air treatment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — avoid duplicating dryers.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFacilities with an existing receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — storage stays separate.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHigh continuous demand\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — 50 HP with a 100% duty cycle.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMulti-compressor rooms\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — network up to six QGS units.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eGear-driven QGS rotary screw compressor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInfologic2 Basic Controller with display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e100% duty cycle TEFC motor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAftercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass and pressure gauge\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAir filter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutdown on engine and pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e230V-3 conversion kit; unit ships wired 460V-3\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e receiver tank, electronic drain valve, integrated air dryer, wiring, installation or commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor power\u003c\/th\u003e\n\u003ctd\u003e50 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFree air delivery (CFM)\u003c\/th\u003e\n\u003ctd\u003e203.2 at 125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e125 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSound level (dBA)\u003c\/th\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eRotary screw, gear drive, oil lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAftercooler\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIntegrated refrigerated dryer\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver tank\u003c\/th\u003e\n\u003ctd\u003eNone supplied, listed as 0 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage and phase\u003c\/th\u003e\n\u003ctd\u003e230\/460 Volt AC, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw and breaker\u003c\/th\u003e\n\u003ctd\u003eConsult a certified electrician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1,184 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions, L x W x H\u003c\/th\u003e\n\u003ctd\u003e52\" x 37.7\" x 61.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eASME\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn ASME certification is listed on the specification sheet. Because ASME coding normally applies to a pressure vessel and this SKU is supplied tankless, the relevant certification question may apply to the receiver you connect to it. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIf you need to know exactly what the certification covers for this part number, ask us before ordering and we will confirm it in writing.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNo independent electrical or equipment safety listing is published for the packaged machine, and we will not imply one. If your insurer, jurisdiction or corporate standard requires a third-party listing, confirm that requirement before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFreight is available within the lower 48 states, with shipping calculated at checkout based on your delivery address. At \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1,184 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the machine requires a loading dock or forklift for delivery. If neither is available, terminal pickup is an alternative.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential deliveries incur a residential fee when applicable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the crate before signing. Photograph any damage and record it on the bill of lading while the driver is present. A clean signature can make concealed-damage claims difficult to pursue.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished standard coverage is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1 year for consumer and commercial use\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. An extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-Year Warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies when the machine is commissioned by a Quincy-authorized start-up provider. Confirm the applicable warranty before first operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor any suspected warranty issue, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before opening the airend or motor.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Keep commissioning paperwork and fluid\/filter service records, as both may be required for a claim.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_7a499af7-7938-47c8-825d-1187dfa10585.pdf?v=1788526835\"\u003eWarranty Details\u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45972111196213,"sku":"4152016900","price":24666.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152016900__32925.1679919622.1280.1280.png?v=1789222971","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-50-hp-tankless-rotary-screw-230-460v-3-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}