{"product_id":"quincy-air-compressor-5103d12vca20m-qt-max-10-hp-120-gallon-two-stage-208v-3-phase","title":"Quincy Air Compressor 5103D12VCA20M QT Max 10 HP 120 Gallon Two Stage 208V 3 Phase","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eQP MAX 10 HP vertical compressor\u003c\/strong\u003e puts \u003cstrong\u003e120 gallons of air storage\u003c\/strong\u003e into a compact \u003cstrong\u003e30\" × 40\" footprint\u003c\/strong\u003e, making it a practical alternative to horizontal receivers that can occupy more than 6 feet of floor space. This two-stage, cast-iron package is rated to \u003cstrong\u003e175 PSI\u003c\/strong\u003e, uses a \u003cstrong\u003e208V 3-phase motor\u003c\/strong\u003e, and includes a mounted air-cooled aftercooler. At \u003cstrong\u003e75\" tall\u003c\/strong\u003e, the vertical configuration trades floor space for ceiling clearance, so verify the available height before ordering.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003etwo-stage pump\u003c\/strong\u003e compresses air in a large and small cylinder with a high-efficiency fin-and-tube intercooler between them. Cooling the air before the second stage improves compression efficiency and reduces heat reaching the valves and other components. After compression, the \u003cstrong\u003eair-cooled aftercooler\u003c\/strong\u003e lowers discharge temperature before the air enters the receiver, helping moisture condense at the compressor rather than farther downstream in your air lines. The package also includes \u003cstrong\u003elow-oil shutdown\u003c\/strong\u003e, a spin-on oil filter, oil sight glass, and magnetic starter for motor protection.\u003c\/p\u003e\n\u003cp\u003eThis compressor is a strong fit for \u003cstrong\u003espace-constrained automotive shops, two- and three-bay workshops, and mixed-use facilities\u003c\/strong\u003e with 208V 3-phase service. Its small floor footprint makes it especially useful when a horizontal tank would interfere with bays, workbenches, or walkways. The tradeoff is height and floor loading: the assembled unit is approximately \u003cstrong\u003e850 lbs\u003c\/strong\u003e, so plan for a level, suitable slab, anchoring, and access to the tank drain and pump for maintenance. A dryer is not included, and electrical feed, disconnect, anchors, and shop air piping must be provided separately.\u003c\/p\u003e\n\u003ch3\u003eThe trade you are making by going vertical\u003c\/h3\u003e\n\u003cp\u003eVertical tanks buy floor space and spend ceiling height. This unit stands 75\" tall, so measure before you commit: you need that height plus room above for the safety valve and for anyone who has to reach the top of the pump. Vertical machines are also less forgiving about the floor. A tall, top-heavy assembly wants a genuinely level slab and, in most installations, anchoring. If your floor slopes to a drain — which many shop floors do — take that into account when you pick the spot, and plan on shimming and anchoring rather than simply standing it in a corner.\u003c\/p\u003e\n\u003cp\u003eThe other consequence is drainage. Condensate collects in the bottom of the tank, and on a vertical receiver that bottom is at floor level rather than at a convenient height. Give yourself real access to the drain before you position the machine, because a drain you cannot reach is a drain that does not get used, and water sitting in a receiver is what eventually ends its life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFloor space:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30\" W × 40\" D. Leave clearance for access to the drain, oil fill and service points.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 75\". Check low ceilings, mezzanines, door tracks, ductwork and overhead lighting before delivery.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 850 lbs on a compact footprint, so verify the slab can support the load.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 208V, 3-phase. Quincy lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e32.2 A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this build. No breaker size is published; a certified electrician should size the circuit based on conductor length and local code.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir connection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3\/4\" tank outlet.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLevelling, anchoring, electrical feed, disconnect and shop piping are the customer's responsibility. Electrical work should be performed by a licensed electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTwo-Stage Compression \u0026amp; Cooling\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump compresses air in two stages with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency fin-and-tube intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between them. Cooling the air before the second stage helps reduce compression heat and improves the second-stage process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCast-iron cylinders provide a durable pump structure, while aluminum heads help dissipate heat. A mounted \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e reduces discharge temperature before air enters the receiver, helping remove moisture before it reaches the shop piping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe system is rated to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSpace-constrained shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e needing a 120-gallon receiver.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTwo- and three-bay workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with 208V three-phase power.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eMixed-use buildings\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where a vertical footprint is easier to accommodate.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eShops upgrading storage\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e without giving up additional floor space.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eThree-phase power is required.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e If your building has only single-phase service, this model is not the right fit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe assembled package includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCast-iron two-stage pump with aluminum heads\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMotor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e120-gallon vertical receiver\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounted air-cooled aftercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFin-and-tube intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpin-on oil filter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil shutoff\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e air dryer, anchors, shims, shop piping, filtration, regulators, disconnect or electrical feed. The final packing list in the crate governs included contents.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e208V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw (as listed by Quincy)\u003c\/th\u003e\n\u003ctd\u003e32.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum heads, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFootprint\u003c\/th\u003e\n\u003ctd\u003e30\" wide × 40\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall height\u003c\/th\u003e\n\u003ctd\u003e75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory warranty, extending to 3 years (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur records list the receiver to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME pressure-vessel code\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e among the unit's marks. ASME certification applies to the pressure vessel itself—its design, materials and construction—not the complete assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your insurer, fleet policy or local authority requires a specific listing for fixed shop equipment, verify that requirement against the data plate before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBefore You Order — Please Confirm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePump lubrication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published details differ. The package name and feature list describe a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efully pressure-lubricated pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while a specification field lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Ask us to confirm the factory configuration.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic tank drain:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published information differs on whether an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic automatic drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is fitted. Confirm this if it is important to your installation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir delivery \u0026amp; pump speed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No verified CFM or pump-speed figures are published for this specific build. Because related voltage models are documented differently, we will not transfer their ratings to this unit. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eContact us for the factory specifications.\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by freight within the lower 48 states, with shipping calculated at checkout. At \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and over six feet tall on its pallet, plan for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eforklift or loading dock\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, or choose terminal pickup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eResidential deliveries incur a residential fee where applicable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the compressor before signing. Check the receiver, feet, guards, gauges and cooler, photograph any damage, and record it on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e applies, with extension to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e subject to Quincy's published warranty terms and conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a problem occurs, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before opening or disassembling the pump.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e A dismantled unit can make diagnosis and warranty evaluation difficult.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_7a499af7-7938-47c8-825d-1187dfa10585.pdf?v=1788526835\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45972333559861,"sku":"2020040795","price":9927.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3103D12VCA20M-2__73813.1679859937.1280.1280.png?v=1789224357","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-5103d12vca20m-qt-max-10-hp-120-gallon-two-stage-208v-3-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}