{"product_id":"quincy-air-compressor-5103d12vca23m-qt-max-10-hp-120-gallon-two-stage-230v-3-phase","title":"Quincy Air Compressor 5103D12VCA23M QT Max 10 HP 120 Gallon Two Stage 230V 3 Phase","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eQP MAX 10 HP vertical compressor\u003c\/strong\u003e delivers \u003cstrong\u003e35 CFM at 175 PSI\u003c\/strong\u003e from a \u003cstrong\u003e120-gallon receiver\u003c\/strong\u003e, giving busy shops substantial stored-air capacity while keeping the floor footprint to just \u003cstrong\u003e30\" × 40\"\u003c\/strong\u003e. The two-stage pump is built for efficient compression to 175 PSI, while the vertical configuration preserves valuable shop floor space. This version runs on \u003cstrong\u003e230V 3-phase power\u003c\/strong\u003e and is rated for continuous-duty operation. Note: the unit stands approximately \u003cstrong\u003e75\" tall\u003c\/strong\u003e, so verify overhead clearance before ordering.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003etwo-stage compression system\u003c\/strong\u003e uses a high-efficiency fin-and-tube intercooler between stages to cool the air before final compression. The result is cooler, denser air entering the second cylinder, helping the pump reach its rated pressure while reducing thermal stress. A \u003cstrong\u003emounted air-cooled aftercooler\u003c\/strong\u003e then lowers discharge temperature before air enters the receiver, encouraging moisture to condense at the compressor instead of farther down the shop air line. A spin-on oil filter, oil sight glass, \u003cstrong\u003elow-oil shutoff\u003c\/strong\u003e, and magnetic starter with thermal overload protection provide additional protection during demanding operation.\u003c\/p\u003e\n\u003cp\u003eThis compressor is a strong fit for \u003cstrong\u003egeneral automotive repair shops, tire and suspension facilities, and multi-bay workshops\u003c\/strong\u003e where several pneumatic tools may operate at the same time. The 175 PSI maximum gives the 120-gallon receiver more pressure headroom to absorb demand spikes before the pump needs to recover, while the compact vertical footprint works well in shops where floor space is limited. At approximately \u003cstrong\u003e850 lbs\u003c\/strong\u003e, it requires a level, properly supported and anchored slab, with adequate access for maintenance. A dryer, air piping, filtration, regulators, disconnect, and electrical feed are not included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy 175 PSI Matters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eMost shop tools operate below the compressor's maximum pressure. The value of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the additional storage and operating headroom it provides.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA receiver charged to 175 PSI can supply longer periods of demand before pressure drops to the cut-in point. That matters when several tools are running or a high-demand tool operates continuously. More pressure headroom can help maintain regulated pressure at the point of use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Stage Compression \u0026amp; Cooling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two-stage pump divides compression between a larger first-stage cylinder and a smaller second-stage cylinder. Between them, a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency fin-and-tube intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e removes heat before the second stage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eCooling the air between stages helps the second stage compress cooler, denser air while reducing thermal stress. \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCast-iron cylinders\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, aluminum heads and a mounted \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eair-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e complete the cooling system, with the aftercooler reducing discharge temperature before air enters the receiver and helping moisture condense at the compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-In Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003espin-on oil filter, oil sight glass and low-oil shutoff\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The filter removes contaminants from the lubrication system, the sight glass makes oil level checks straightforward, and the low-oil protection shuts the machine down when lubrication becomes insufficient.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e protects the motor from overload conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFloor:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30\" W × 40\" D. The vertical receiver provides 120-gallon capacity on a compact footprint.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 75\". Check overhead ductwork, lighting, door tracks and mezzanines.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 850 lbs. Install on a level, load-bearing slab and anchor as required.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 230V, 3-phase. Quincy lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e28 A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. No breaker size is published; a certified electrician should size the circuit for the actual installation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOutlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3\/4\" tank outlet.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eSite preparation, levelling, anchoring, electrical feed, disconnect and air-system connection are the customer's responsibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir delivery\u003c\/th\u003e\n\u003ctd\u003e35 CFM at 175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e230V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw (as listed by Quincy)\u003c\/th\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum heads, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFootprint\u003c\/th\u003e\n\u003ctd\u003e30\" wide × 40\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall height\u003c\/th\u003e\n\u003ctd\u003e75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory warranty, extending to 3 years (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit’s recorded certifications include \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME pressure-vessel code for the receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA mark\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. ASME certification applies specifically to the pressure vessel, not automatically to the complete machine. If your insurer, inspector, or local authority requires a specific equipment listing, verify it against the unit’s data plate before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBefore You Order — Please Confirm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLubrication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published information conflicts between \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressure lubrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. If this matters to your purchase, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econfirm with us in writing before ordering\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eTank drain:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published specifications differ on whether an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomatic electronic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is fitted. Confirm before ordering if you require one.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePump speed:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No pump RPM is published for this specific build. We will not substitute a figure from another model.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by freight within the lower 48 states, with the rate calculated at checkout. The unit weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and ships palletized, so plan for a forklift or loading dock. Terminal pickup is also available. Residential delivery adds a residential fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the unit before signing for delivery. Check the tank, feet, belt guard, gauges, and cooler, and record any damage on the bill of lading with the driver present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIncludes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, extendable to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3 years under Quincy’s “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, subject to the requirements in the warranty handbook.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDo not disassemble the pump before contacting us about a warranty claim.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Unauthorized disassembly can affect warranty coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_7a499af7-7938-47c8-825d-1187dfa10585.pdf?v=1788526835\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45972619329589,"sku":"2020040796","price":9927.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3103D12VCA23M-2__40944.1679860128.1280.1280_6789e4f7-036b-4d2a-862f-b28cf54d5ad1.png?v=1789224681","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-5103d12vca23m-qt-max-10-hp-120-gallon-two-stage-230v-3-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}