{"product_id":"quincy-air-compressor-5103d12vca46m-qt-max-10-hp-120-gallon","title":"Quincy Air Compressor 5103D12VCA46M QT Max 10 HP 120 Gallon","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eQP MAX 10 HP vertical compressor\u003c\/strong\u003e combines a large, slow-running cast-iron pump with a \u003cstrong\u003e120-gallon receiver\u003c\/strong\u003e and a \u003cstrong\u003e100% continuous-duty rating\u003c\/strong\u003e. Operating at \u003cstrong\u003e1,750 RPM\u003c\/strong\u003e, the two-stage pump is designed to deliver sustained air with less heat and mechanical wear than a smaller, faster-running pump. This version is built for \u003cstrong\u003e460V 3-phase power\u003c\/strong\u003e and has a listed \u003cstrong\u003e14A draw\u003c\/strong\u003e, making it especially practical for facilities that already have 460V distribution. Note: the unit measures approximately \u003cstrong\u003e30\" W × 40\" D × 75\" H\u003c\/strong\u003e, so ceiling clearance is critical.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe cooling system supports the continuous-duty design with a \u003cstrong\u003efin-and-tube intercooler\u003c\/strong\u003e between the compression stages and a mounted air-cooled aftercooler after the pump. The intercooler cools air before it enters the second stage, while the aftercooler lowers discharge temperature before the air reaches the receiver, helping moisture condense at the machine instead of throughout the shop piping. A \u003cstrong\u003emagnetic starter with thermal overload\u003c\/strong\u003e, low-oil shutdown, oil sight glass, and spin-on oil filter provide straightforward protection for the motor and pump during extended operation.\u003c\/p\u003e\n\u003cp\u003eThis compressor is well suited to \u003cstrong\u003eindustrial facilities with existing 460V 3-phase service\u003c\/strong\u003e, production shops running compressed air throughout the workday, and space-constrained plant rooms with sufficient ceiling height. The vertical design keeps the 120-gallon receiver within a compact \u003cstrong\u003e30\" × 40\" footprint\u003c\/strong\u003e, while the 850-lb weight means the installation needs a level, suitable slab and appropriate anchoring. Plan access for the tank drain, pump maintenance, and cooling airflow. Air piping, filtration, regulators, disconnect, electrical feed, and condensate routing are handled separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e460V and Installation Cost\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy lists this build at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e14 A on 460V three-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The higher supply voltage keeps current low, which can reduce conductor, conduit, breaker and disconnect requirements compared with lower-voltage versions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf your facility already has 460V service, this configuration is a natural fit. If it does not, compare the installation cost before adding a transformer for a single compressor.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for Continuous Duty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eContinuous operation depends on effective cooling. This unit uses a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efin-and-tube intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between the compression stages and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emounted air-cooled aftercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e downstream of the pump. The aftercooler lowers discharge temperature and helps condense moisture before air enters the receiver.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eProtection includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emagnetic starter with thermal overload, low-oil shutdown, oil sight glass and spin-on oil filter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for straightforward monitoring and maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eFootprint:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 30\" W × 40\" D\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eHeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 75\" overall — check ceiling clearance, lighting, overhead services and door tracks.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 850 lbs. Install on a level slab; anchoring is strongly recommended.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePower:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 460V three-phase, 14 A listed by Quincy. Breaker sizing is not published; a licensed electrician should size the installation for the actual run and local code.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir outlet:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 3\/4\" tank outlet.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eDrainage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Plan for condensate from continuous operation and the aftercooler.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe customer is responsible for the slab, leveling, anchoring, electrical feed, disconnect, air piping and condensate routing. Electrical work should be completed by a licensed electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan\u003eFacilities with existing \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e460V three-phase service\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOperations running compressed air throughout the day\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpace-limited plant rooms with sufficient ceiling height\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFacilities replacing a compressor that struggles with continuous demand\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAssembled package with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecast-iron two-stage pump, aluminum heads, motor, 120-gallon vertical receiver, magnetic starter, mounted air-cooled aftercooler, fin-and-tube intercooler, spin-on oil filter, oil sight glass and low-oil shutdown\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNo air dryer is included.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Anchoring hardware, shop piping, filtration, regulators, disconnect and electrical feed are not included. Check the shipment against the packing list on arrival.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump speed\u003c\/th\u003e\n\u003ctd\u003e1,750 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003eContinuous, 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e460V, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmp draw (as listed by Quincy)\u003c\/th\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum heads, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e120 gallons, vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFootprint\u003c\/th\u003e\n\u003ctd\u003e30\" wide × 40\" deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall height\u003c\/th\u003e\n\u003ctd\u003e75\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory warranty, extending to 3 years (see below)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Honestly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis unit’s records list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME pressure-vessel code for the receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCSA mark\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. ASME certification applies to the pressure vessel itself, not automatically to the complete machine. If your insurer, fleet policy, or local authority requires a specific equipment listing, verify the requirement against the machine’s data plate before ordering. We can help confirm the factory documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBefore You Order — Please Confirm\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLubrication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Published information conflicts between \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressure lubrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esplash lubrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. We will confirm the lubrication method with the factory before you order.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAutomatic tank drain:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Records differ on whether an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectronic automatic tank drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is fitted. Confirm if this feature is important to your installation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eAir delivery:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e No verified CFM figure is published for this specific build. We will provide the factory rating rather than substitute a figure from another model.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by freight within the lower 48 states, with the rate calculated at checkout. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850 lb palletized unit\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requires a forklift, loading dock, or carrier terminal pickup. Residential delivery adds a residential fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the tank, feet, guards, gauges and cooler before signing. Record any damage on the bill of lading with the driver present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIncludes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, extending to a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e subject to the terms and conditions in Quincy’s warranty handbook.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a problem occurs, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before opening or disassembling the pump\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Unauthorized disassembly can affect warranty coverage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_7a499af7-7938-47c8-825d-1187dfa10585.pdf?v=1788526835\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45972626702389,"sku":"2020040797","price":9927.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3103D12VCA46M__90863.1679860295.1280.1280_b24ad6f2-b044-4549-9bab-9515ab934f0a.png?v=1789224847","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-5103d12vca46m-qt-max-10-hp-120-gallon","provider":"Car Lift Supply","version":"1.0","type":"link"}