{"product_id":"quincy-air-compressor-60-gallon-two-stage-230v-1-phase","title":"Quincy Air Compressor 60 Gallon Two Stage 230V 1 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy 2V41C60VC 5 HP compressor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a 230V single-phase, two-stage machine built for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% continuous-duty operation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a 60-gallon vertical receiver and 175 PSI maximum working pressure. Before ordering, plan the electrical installation: this model has \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eno magnetic starter or power cord supplied\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, Quincy specifies a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50-amp breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and installation must be performed by a qualified technician. The pump uses a splash-lubricated cast-iron design with an aluminum head, stainless steel reed valves, and a balanced cast-iron flywheel, providing a practical stationary compressor for demanding shop and garage use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe two-stage pump compresses air in steps, with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned-tube intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e cooling the air between stages before it enters the second cylinder. That reduces heat during compression and helps the machine maintain its 175 PSI working capability under extended operation. The low-speed pump, industrial-grade bearings, extra-capacity oil reservoir, and low oil pump temperature protection are designed to support the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the balanced flywheel helps control vibration and directs cooling air across the pump. The stainless steel reed valves provide corrosion resistance, and the aluminum head helps dissipate heat generated during operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis compressor is well suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esingle-bay automotive shops, serious home garages, and smaller workspaces\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with 230V single-phase service that need more capacity than a portable compressor can provide. Its 60-gallon vertical receiver occupies approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e29\" × 21\"\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of floor space and stands about 70\" tall, with a total weight of 475 lbs. Confirm panel capacity, ceiling clearance, floor condition, and access before delivery. Because there is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eno factory magnetic starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, coordinate the appropriate starter, switchgear, wiring, and disconnect with your electrician. The 1\/2\" tank outlet and manual drain also mean downstream air treatment and routine tank draining should be incorporated into the installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat That Means in Practice\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBudget for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eswitchgear, wiring and electrical installation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e alongside the compressor. This \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5 HP, 230V single-phase\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e model requires a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e50-amp breaker\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e according to Quincy, so confirm that your panel has sufficient capacity and an available double-pole position before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA magnetic starter is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot included\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with this configuration. The motor has built-in thermal overload protection, while the required starter and disconnect should be selected and installed by a qualified electrician based on the installation and local code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Duty \u0026amp; Cooling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe pump is rated for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% duty cycle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and uses a low-speed, splash-lubricated cast-iron design with an extra-capacity oil reservoir, low-oil pump-temperature protection, industrial-grade bearings and a balanced cast-iron flywheel.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eTwo-stage compression passes air through a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehigh-efficiency finned-tube intercooler\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between stages before reaching the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rated pressure. The aluminum head helps with heat dissipation, while \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003estainless-steel reed valves\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provide corrosion resistance and durability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCylinder Count: Please Confirm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe product information gives \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econflicting cylinder counts\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in different sections. Rather than guess, we recommend confirming the exact cylinder configuration with us against a current Quincy specification sheet if it matters to your purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAir Delivery: Please Confirm\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur specification record lists \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15.2 CFM at 175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, but the unit of measure is not independently established elsewhere in the product data. Because air-system sizing depends on an accurate flow rating, confirm the factory CFM figure before designing your piping or selecting downstream equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60-gallon vertical receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requires approximately a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e29\" × 21\" footprint\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, stands about \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e70\" tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and weighs \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e475 lb\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eVerify ceiling height and service clearance around the gauge, belt guard and drain. Install the compressor on a flat, solid, level surface.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tank has a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1\/2\" outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emanual drain\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. No air dryer, filtration or regulation is included, so downstream air treatment must be supplied separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSingle-bay shops and serious home garages with 230V single-phase service.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuyers with adequate panel capacity and access to qualified electrical installation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eContinuous-duty applications such as sanding, blasting and extended air-tool use.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eShops where a larger stationary compressor will not fit.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's in the Box\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe factory assembly includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eTwo-stage splash-lubricated cast-iron pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAluminum head and stainless-steel reed valves\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHeavy-duty capacitor-start motor with thermal overload\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHigh-efficiency finned-tube intercooler\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBalanced cast-iron flywheel\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExtra-capacity oil reservoir\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLow-oil pump-temperature protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePressure gauge and enclosed belt guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eVertical \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60-gallon coded receiver\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePressure relief valves\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eManual tank drain\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e1\/2\" tank outlet\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e magnetic starter, power cord, disconnect, air dryer, filtration, regulation or shop piping. Installation must be performed by a qualified technician.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSupply and electrical\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated power\u003c\/th\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSupply\u003c\/th\u003e\n\u003ctd\u003e230 Volt AC, 1-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRecommended breaker\u003c\/th\u003e\n\u003ctd\u003e50 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMagnetic starter\u003c\/th\u003e\n\u003ctd\u003e\u003cstrong\u003eNot fitted\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower cord\u003c\/th\u003e\n\u003ctd\u003e\n\u003cstrong\u003eNot supplied\u003c\/strong\u003e — hard-wired installation by a qualified technician\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor protection\u003c\/th\u003e\n\u003ctd\u003eCapacitor start with built-in thermal overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003ePump\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, belt drive, splash lubricated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterials\u003c\/th\u003e\n\u003ctd\u003eCast iron with aluminium head; stainless steel reed valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDuty cycle\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDelivered air\u003c\/th\u003e\n\u003ctd\u003eRecorded in our data as 15.2 cubic feet per minute at 175 PSI. Ask us to confirm it in writing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCylinder count\u003c\/th\u003e\n\u003ctd\u003eOur two sources disagree. Ask us and we will confirm it against a current Quincy sheet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eLow oil pump temperature protection; extra-capacity reservoir\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTank and dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e60-gallon, vertical, coded, with pressure relief valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutlet\u003c\/th\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDrain\u003c\/th\u003e\n\u003ctd\u003eManual — no electronic drain valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOverall\u003c\/th\u003e\n\u003ctd\u003e29\" × 21\" × 70\" high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e475 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe receiver is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecoded pressure vessel\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e built to the applicable American standard and fitted with pressure relief valves. The motor carries \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and CSA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e electrical certifications, and Quincy states that the unit is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuilt in the U.S.A.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThese claims do not establish a third-party safety listing for the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecomplete assembled machine\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Because the starter and wiring are specified for the installation, confirm any complete-unit listing requirements with your insurer, fleet standard or local inspector before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Receiving\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003ePalletized freight is available within the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with shipping calculated live at checkout based on your delivery address.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan the unloading in advance. The carrier delivers to the tailgate, so you need a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eloading dock, forklift or pallet jack on firm, level ground\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Without suitable equipment, arrange terminal pickup and collect the pallet yourself. Residential delivery carries an additional fee.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the shipment before signing. Check the pallet, crate and compressor for visible damage, photograph anything questionable and record it on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with coverage extending to Quincy's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year “No Bull” warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e under the manufacturer’s conditions. Review the warranty documentation for the requirements that apply to this model before relying on the extended term.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf the pump develops a fault, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edo not disassemble it before contacting us\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Keep the equipment assembled so the failure can be inspected before repairs are attempted.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_2.pdf?v=1788636197\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45974536945717,"sku":"2021116649","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/2V41C60VC__59505.1679754391.1280.1280_9b2cc40a-63d9-4aee-a487-4b30be53ca29.jpg?v=1788636273","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-60-gallon-two-stage-230v-1-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}