{"product_id":"quincy-air-compressor-7-5-hp-60-gallon-single-stage-230v-1-phase","title":"Quincy Air Compressor 7.5 HP 60 Gallon Single Stage 230V 1 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQGS 7.5\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a 7.5 HP rotary screw compressor that brings \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100% continuous-duty air\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to shops with 230V single-phase power. Unlike many screw compressors designed around three-phase industrial service, this model delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e20.4 CFM at 150 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e from a standard 230V 1-phase supply, making continuous compressed air possible without upgrading to three-phase utility service. Its quiet enclosure produces just \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e64 dBA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing the compressor to operate in a working area without the constant disruption associated with a conventional piston machine.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe oil-injected twin-screw airend compresses air through two meshing rotors rather than reciprocating pistons, providing a steady supply without the pressure pulses and repeated cycling associated with piston compressors. The oil simultaneously \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eseals the rotor clearances, removes heat, and lubricates the bearings\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, supporting continuous operation throughout the workday. A synthetic lubricant rated for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e8,000 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e helps extend service intervals, while the long-life V-belt drive provides a straightforward maintenance point. The TEFC motor uses an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIP55-rated enclosure\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to protect the motor from dust and moisture, and low oil carryover helps keep the compressed-air stream cleaner.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis compressor is particularly well suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esingle-phase automotive and commercial workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that need sustained air delivery but do not have access to three-phase power. It also makes sense for work environments where technicians spend their day near the compressor, including \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epaint, cabinet, and finishing operations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that benefit from consistent air pressure. The 64 dBA sound level and 100% duty rating make it a practical alternative when a piston compressor would be too disruptive or would spend too much time cycling at its duty limit. Note: the unit is specified for a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eminimum ambient temperature of 36°F\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so installation in an unheated space should be evaluated accordingly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy a Screw Compressor Is Different\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA piston compressor runs in cycles: it builds pressure, reaches cut-out, stops, then restarts as demand lowers tank pressure. A rotary screw compresses air continuously between two meshing rotors, making 100% duty operation a core part of its design.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThis oil-injected twin-screw airend uses oil to seal rotor clearances, remove heat and lubricate the bearings. The result is a steady air supply suited to applications that need extended, continuous operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e64 dBA: A Quieter Shop Environment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specified sound level is 64 dBA, with the compressor housed in a standard quiet enclosure. That makes noise a practical consideration when the machine needs to operate near workers rather than in a separate compressor room.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt for Continuous Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package uses premium synthetic lubricant rated for up to 8,000 hours and a long-life V-belt drive. The TEFC motor carries an IP55 rating, protecting the motor from dust and water exposure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eControl is through a UL and cUL compliant start\/stop panel. The specified minimum ambient temperature is 36°F, so confirm that your installation stays above this limit in cold weather.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill It Fit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor is mounted on a horizontal 60-gallon receiver and measures:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e56\" L × 23\" W × 51\" H\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e465 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e1\/2\" tank outlet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003e230V single-phase\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eMagnetic starter included\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eLeave adequate clearance around the enclosure for cooling airflow and service access. Confirm the electrical supply, breaker\/conductor requirements, doorway dimensions, access route and floor capacity before ordering. Electrical installation should be handled by a qualified electrician.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSingle-phase workshops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e needing continuous compressed air\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eNoise-sensitive workspaces\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where the compressor operates near employees\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003ePainting, cabinet and finishing applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requiring steady air delivery\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eSmall commercial and light industrial shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with extended air demand\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Arrives\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe package includes the oil-injected twin-screw airend, TEFC motor, V-belt drive, quiet enclosure, control panel and horizontal 60-gallon receiver.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe available documentation does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e list a hose, downstream filtration, dryer, regulator or isolation valve as included. Plan for those separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf you're using the extended warranty, arrange any required Quincy maintenance kits and authorized startup during installation rather than afterward.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eRotary screw, oil-injected twin screw pump, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e7.5 HP, 230V, 1-phase, TEFC, IP 55 washdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDelivery\u003c\/th\u003e\n\u003ctd\u003e20.4 CFM at 150 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty\u003c\/th\u003e\n\u003ctd\u003e100% continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSound level\u003c\/th\u003e\n\u003ctd\u003e64 dBA, standard quiet enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003ePremium synthetic, rated 8,000 hours, low oil carryover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003ctd\u003eStart and stop operation, UL and cUL compliant panel, minimum ambient 36°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReceiver\u003c\/th\u003e\n\u003ctd\u003e60 gallons, horizontal, 1\/2-inch outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e56 inches long, 23 inches wide, 51 inches high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e465 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Plainly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe specification sheet lists an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME mark\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for the pressure vessel and states that the control panel is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUL and cUL compliant\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe ASME certification applies to the receiver’s design, materials and construction. UL\/cUL compliance applies to the electrical controls—not the complete machine.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eNeither certification covers breathing-air or food-contact air quality, and neither replaces local requirements for pressure-vessel registration, permits or inspections. Check your local requirements before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eFreight only to the lower 48, with live shipping rates calculated at checkout.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePlan unloading before delivery: you’ll need a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eforklift or loading dock\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, or you can arrange terminal pickup if neither is available. Residential delivery carries an additional fee, so provide the correct destination type when ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the shipment before signing. Check the guards, gauges, receiver and packaging for damage. Photograph anything questionable and record it on the bill of lading while the driver is present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBase coverage is a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn extended \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is available with Quincy registration and required Quincy maintenance kits. The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue Blue 5-year warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e requires a Quincy-authorized startup and covers the airend, motor, separator reservoir, cooler and heat exchanger.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eIf the 5-year warranty matters to your purchase, arrange the authorized startup \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebefore commissioning\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. It is a warranty requirement, not simply an optional service.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a fault occurs, contact us before disassembling the compressor. Keep the machine assembled so the manufacturer can properly assess the failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_2.pdf?v=1788636197\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45974540910645,"sku":"4152051928","price":8738.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/4152005429__06017.1680020506.1280.1280.png?v=1788636697","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-7-5-hp-60-gallon-single-stage-230v-1-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}