{"product_id":"quincy-air-compressor-pro-10-hp-two-stage-208v-3-phase","title":"Quincy Air Compressor Pro 10 HP Two Stage 208V 3 Phase","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eQuincy QP Pro 10 HP\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a horizontal air compressor built for shops where ceiling height is the limiting factor. At approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e55 inches tall\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, its low-profile layout can fit beneath mezzanines, low ceilings, benches, or overhead door tracks where a vertical compressor cannot. It uses a fully pressure-lubricated two-stage pump with cast iron cylinders and aluminum heads, driven by a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10 HP motor on 208V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and rated to 175 PSI. Published information identifies the receiver inconsistently as either a 120-gallon horizontal tank or an 80-gallon vertical tank; the dimensions and model family align with the horizontal configuration, so tank size and orientation should be confirmed before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe horizontal design trades floor space for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ereduced overall height\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, making use of the long, narrow areas along a shop wall while keeping regularly serviced components within easier reach. The QP Pro pump uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressure lubrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e rather than splash lubrication, delivering oil to the bearings from the start of operation and allowing a spin-on filter to remove contaminants from the lubrication system. An oil sight glass provides a quick way to monitor the oil level. This arrangement is particularly useful for a compressor that may start and stop repeatedly throughout the workday, while the two-stage pump provides efficient compression to the 175 PSI operating rating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis compressor is suited to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eautomotive repair shops, fabrication facilities, fleet operations, and other professional shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that have sufficient floor space but limited overhead clearance. The published model code also varies between 5103DS12HCA20 and 3103DS12HCA20, so the exact code should be confirmed with your quote. The unit requires \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e208V three-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, solid level concrete, adequate cooling and service clearance, and an installation route capable of accommodating its horizontal dimensions and approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850-lb weight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Quincy specifies a magnetic starter but does not publish a breaker size, so the electrical installation should be sized by a qualified electrician according to the actual installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Things to Confirm Before You Order\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003ePublished information for this build differs in two areas. Please confirm both in writing before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eTank size and orientation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The description heading, specification fields and product record list a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e120-gallon horizontal receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while one paragraph describes an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e80-gallon vertical receiver\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. The published dimensions — approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e78\" L × 28\" W × 55\" H\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e — and model family align with the horizontal configuration. If tank size or orientation matters to your installation, ask us to confirm it with Quincy before ordering.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eModel code:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The product title, heading and specifications list \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e5103DS12HCA20\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, while the page URL and one description reference \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3103DS12HCA20\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Send us the model code shown on your quote so we can confirm the exact build.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy Choose a Horizontal Receiver?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA horizontal receiver uses more floor space but requires less overhead clearance. It also keeps the belt guard, oil sight glass, drain and outlet at a more accessible working height.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eA vertical receiver of similar capacity generally uses less floor space but requires more ceiling height. Choose based on your available installation space.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Lubrication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe QP Pro pump uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epressure lubrication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with an oil pump and spin-on oil filter. Oil is circulated through the lubrication system, while the filter helps remove contaminants before they continue through the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAn \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eoil sight glass\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e provides a quick way to check the oil level.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAir Delivery — Confirm Before Ordering\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eOur specification record contains an air-delivery figure at \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e175 PSI\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, but the unit of measurement is not verified in the available data. We therefore do not publish the number on this page.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eAsk us for the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efactory-rated CFM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and we will confirm it in writing along with the tank configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInstall on a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elevel, solid concrete surface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with adequate clearance for cooling airflow and service access. The unit weighs approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, so confirm that the floor and access route can accommodate it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eBecause this is a long horizontal compressor, measure the delivery path carefully, including doorways and turns.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eElectrical:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 208V, 3-phase with a magnetic starter. Quincy does not publish a specific breaker size for this build and recommends consulting a certified electrician. Conductor sizing and overcurrent protection depend on the installation and applicable electrical code.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCustomer responsibilities:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e floor preparation, clearance, delivery access and electrical installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerfect For\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eLow-ceiling shops\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e such as basements, converted spaces and bays with overhead door tracks\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eWall installations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where a long, low compressor fits unused floor space\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003cspan\u003eOwners who handle routine service\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and prefer easy access to the drain and oil sight glass\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003cspan\u003eFacilities with 208V, 3-phase power\u003c\/span\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's Included\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor ships factory assembled with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003ePressure-lubricated two-stage pump\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMotor and belt drive with guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eHorizontal receiver\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMagnetic starter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpin-on oil filter\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOil sight glass\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWarranty documentation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eNot included:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e electrical feed or disconnect, piping beyond the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3\/4\" tank outlet\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, downstream filtration or drying, anti-vibration pads or first-service consumables.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003e5103DS12HCA20 (a second code exists in our data - see above)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMotor\u003c\/th\u003e\n\u003ctd\u003e10 HP, 208 Volt, 3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum pressure\u003c\/th\u003e\n\u003ctd\u003e175 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePump\u003c\/th\u003e\n\u003ctd\u003eTwo-stage, cast iron with aluminum head, belt drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLubrication\u003c\/th\u003e\n\u003ctd\u003eFully pressure lubricated, spin-on oil filter, sight glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank\u003c\/th\u003e\n\u003ctd\u003eDisputed in our data - see the note above. Confirm before ordering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTank outlet\u003c\/th\u003e\n\u003ctd\u003e3\/4 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLength\u003c\/th\u003e\n\u003ctd\u003e78 inches (per the horizontal record)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e28 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e55 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e850 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStarter\u003c\/th\u003e\n\u003ctd\u003eMagnetic starter fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e1-year factory warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eCertification, Stated Clearly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eQuincy’s records list an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eASME receiver with UL and CSA markings\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for this unit. These certifications should be interpreted according to their specific scope and do not replace local installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eElectrical supply, disconnects, overcurrent protection and ventilation must meet applicable codes and be handled by a qualified electrician. If an insurer, landlord or authority requires specific documentation, request it before ordering. Given the tank configuration discrepancy noted above, we recommend confirming the factory documentation as part of the purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eShipping \u0026amp; Delivery\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eShips by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003efreight to the lower 48 states\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, with the rate calculated at checkout based on your ZIP code. Residential deliveries may incur an additional fee. Commercial delivery with a dock or forklift, or freight-terminal pickup, may be more practical for a unit of this size.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cstrong\u003e\u003cspan\u003eUnloading is the customer’s responsibility.\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e At approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e850 lbs\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the compressor requires appropriate unloading equipment such as a forklift, loading dock or equipped freight terminal.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eInspect the crate and compressor before signing. Check the tank, pump, motor and other visible components, and document any damage on the bill of lading with the driver present.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe compressor includes a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1-year factory warranty\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Warranty documentation supplied with the machine outlines coverage and any registration requirements; we can provide the terms before purchase.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIf a fault occurs, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtact us before disassembling the pump, motor or starter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e. Keep the components intact and document the issue with photos so the warranty claim can be evaluated properly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/Quincy_Compressor_Warranty_Handbook_03_2025_2.pdf?v=1788636197\"\u003e\u003cspan\u003eWarranty Details\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Quincy Compressor","offers":[{"title":"Default Title","offer_id":45974606348341,"sku":"2020040898","price":7343.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0707\/9454\/3157\/files\/3103DS12HCA20__48614.1679860537.1280.1280.png?v=1788640698","url":"https:\/\/carliftsupply.com\/products\/quincy-air-compressor-pro-10-hp-two-stage-208v-3-phase","provider":"Car Lift Supply","version":"1.0","type":"link"}